HomeMy WebLinkAboutBLD98-087City of Port Townsend
Building and Community Development
540 Water Street
Port Townsend, WA 98158
BUILDER'S PERMIT AND INSPECTION RECORD
S THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2375 HIGHLAND LP
Parcel No: 955900048
Project:
JAIME KOZELISKY
1112 S. JACOB MILLER ROAD
PORT TOWNSEND, WA 98368
Issued: 6126/98
Lot: 48 Block:
PERMIT # BLD98-00087
WNE
HAMILTON HEIGHTS, LLC
1140 140TH AVENUE NE
SUITE D
-PROJECT DESCRIPTIO
New Manufactured Home 1801 sq ft; 992 sq ft garage; porches 301 sq ft; 390 sq ft decks; 240 sq ft heated storage
City Contact: JLZ Construction Type/Occ Use/Occ Load
Type of work: NEW Construction Occupancy
Type of use: SFR Type 1: SN Group 1: R3 Load t: 6
Census Category: 101 Type 2: Group 2: U-1 Load 2: 5
Estimated Value: $56,22270
Type 3: Group 3: Load 3:
Zoning: PUD
SI Code: Type 4: Group 4: load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~ ~ -LIFER
Insp-See Special Conditions ~y FOUNDATION
Insp-See Special Conditions ,3 Insp-See Special Conditions ~(p
TEMP EROSION & SDM'T CON -Stem Wall
Insp-See Special Conditions ~,f' -Forms
FOOTINGS -Reinforcement
Insp-See Special Conditions ~ -Anchor Bolts ~ f~, ~'
-Setbacks -Vents
-Footings - _t ~~~(~J ~ ~ ~ " ~' -Crawl Access
-Forms -Alt BWP Holdown Hdwr
-Reinforcement SLAB ~~ ~ c ~~ ~:
-Interior Footing Insp-See Special Conditions ~'
-_orchfDeck Bay Piers -Setbacks
Ir..J
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
City of Port Townsend Port ownsend tWA 98366
Building and Community Development
,.
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2375 HIGHLAND LP Issued: s/2s/ss
Parcel No: 955900048 pE~j~ IT # Block:
Project: BLD98-00087
Inspection Date Inspector Inspection Date Inspector
-Forms -Whole House Fan
-Slab FRAMING
-Reinforcement Insp-See Special Conditions ~.~'
-Interior Footing Insp-See Special Conditions ~,~$
-Insulation -Walls
-Anchor Bolts -Alternate Braced Wall Panel
FLOOR FRAMING -Roof
Insp-See Special Conditions ,fig -Attic Venting
-Girders -Rafter/Truss Pos. Conn.
-Joists -Weather Resistive Barrier ZZ
-Positive Connection INSULATION
-Treated Wood to Concrete -Slab (R10)
PLUMBING -Floor (R-19)
Insp-See Special Conditions ~9 -Ceiling (R-38)
Insp-See Special Conditions ~~~ -Baffles b/
Insp-See Special Conditions #~~ VAPOR BARRIER
Insp•See Special Conditions ~~~ Insp-See Special Conditions ~~
Insp-See Special Conditions #~3 -Crawl Space - 6 Mil Poly
Insp-See Special Conditions ,~~ DRYWALL NAILING
-Water Supply -Walls
-Hose Bibs (bckflw pro. regd) -Ceiling
-Pipe Insulation -Garage/House Occ. Separation f
-Seismic Restraint DRAINAGE
MECHANICAL Insp-See Special Conditions ~.~
Insp-See Special Conditions ~~ -Per Master Plan
Insp-See Special Conditions -~~6 FINAL
-Duct Insulation Insp-See Special Conditions ~f
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
City of Port Townsend Port ownsendtWA 98368
• Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2375 HIGHLAND LP
Parcel No: 955900048
Project:
Inspection Date Inspector
Insp-See Special Conditions ~~~
Final-House Number
Final-Plumbing
Fina I-Mech a nica I/Heating
Final-Insulation Certificate
Final-Vapor Barrier Cert.
Final-Smoke Detectors
Final-Public Works Sign-Off
Final -Electrical (L&I)
Final -Building ~
SPECIAL CONDITIONS /RESTRICTIONS
Issued: 6/26!98
Lot: 48 Block:
PERMIT # BLD98-00087
1 . HOURS: Outdoor construction activities shall be limited to the hours of 7:30 a.m. to 6:00 p.m.
Monday through Friday and prohibited on weekends and national holidays.
2. Dust control measures shall include watering of the site, backfilling as soon as possible and
sweeping impervious surfaces where soil may be tracked. Chemical dust suppressants shall
not be used.
3. Trees greater than 12" in diameter ~ 4 feet above ground and mare than 10' from the building
pad shall be field marked for the contractor and not removed.
4. TESC: Erosion and sediment control measures to be installed on-site during construction per
Hamilton Heights Master Plan and DOE Best Management Practices.
5. FOOTINGS: Applies to garage/storage/porch/deck.
6. FOUNDATION: Applies to garage.
7. SLAB: Reinforced concrete slab for home requires minimum 4 1/4" slab.
8. FLOOR FRAMING: Applies to deck.
9. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
10. PLUMBING: Main shut-off valve to be installed in water supply piping prior to connection to
home. Valve shall be full-flow type (gate or ball valve); minimum 3/4" diameter, same as
supply pipe.
11 . PLUMBING: Freeze protection (insulation) required forwater supply pipes outside and in crawl
space.
12. PLUMBING: Pressure test required; water pressure at 100 psi far 15 minutes.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend 540 Water Street
PortTownsend, WA 96368 '
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2375 HIGHLAND LP Issued: 6/26/98
Parcel No: 955900048 pE~1~IT # Block:
Project: BLD98-00087
SPECIAL CONDITIONS !RESTRICTIONS
13. PLUMBING: Water heater pressure relief valve drain shall extend outside of skirting, with
elbow down and terminate between 6 "and 24" above ground.
14. PLUMBING: Horizontal runs in drainage system shall be sloped minimum 1/4" per foot.
15. MECHANICAL: Whole house exhaust fan timer shall be set to operate for 2 4-hour periods per
day unless central exhaust fan is set to run continuously.
16. MECHANICAL: Dryer exhaust shall be vented to the outside. Extension into crawl space
requires venting through skirting with no dips; follow dryer manufacturer's instructions.
Moisture exhaust duct shall not exceed total combined vertical and horizontal length of 14 feet
with 2 90-degree elbows.
17. FRAMING: All elements of alternate braced wall panel require inspection prior to cover.
18. FRAMING: Engineered truss plan shall be on- site and alteration insignia shall be posted on
house at inspection time.
19. VAPOR BARRIER: Required on warrn side of walls in conditioned space (heated storage):
kraft paper (faced batt insulation), 4 mil poly or vapor barrier paint.
20. DRAINAGE: All water drains piped to outside shall drain away from home; ground to slope
away from home for minimum 5 feet ~ 112" per foot.
21 . FINAL: Pier supports and anchors per manufactured home installation manual require
inspection prior to skirting.
22. FINAUSKIRTING: No holes or gaps greater than 1/4" allowed in skirting. Crawl space
ventilation per manufacturer's specs or 1/150 (12 req'd.), located on at least two opposing sides
to provide for cross ventilation. Crawl space access required: one (1) per section or as
required by manufacturer; minimum 18" x 24".
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates ~`
1-800-424-5555