HomeMy WebLinkAboutBLD98-049City of Port Townsend 540 Water Street Port Townsend, WA 98366 Building and Community Development ~ BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8r APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1319 57TH ST Parcel No: 972904301 Project: Issued: 5/19198 Lot: Block: BLD98-00049 RICHARD M NELSON JOAN P. NELSON 1319 57TH ST OWNE SPENCER GILLIAN 2940 SEASHORE PT VIRGINIA BEACH, VA 234541858 -PROJECT DESCRIPTIO Repair/Remodel Kitchen and add one bathroom City Contact: JZ Construction TypefOCC UselOcc Load Type of work: ADD Construction Occupancy Type of use: SFR Type 1: Group 1: Load 1: Census Category: 434 Type 2: Group 2: Load 2: Estimated Value; $19,850.00 Type 3: Group 3: Load 3: Zoning; R-II 31 Code: Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector Insp-See Special Conditions MECHANICAL '~r, fcn;~ ;1 TEMP EROSION & SDM'T CON -Source Specific Fan ~~ GROUNDWORK PLUMBING ~ t ~+ /~, ~; ~ FRAMING ~{ •~ ~+ ~~ i'"+ FOOTINGS -Walls -Setbacks -Window U Value -Reinforcement -Window Safety Glazing -LIFER ~J ~_ Kati / -Air Seal -Monolithic SI /Fdn -Door U Value -Anchor Bolts -RafterlTruss Pos. Conn. ~~ '~~ ~ ~~ PLUMBING (f "~ .~~? ~ % -Fire Blocking ~/ -Rough-In (D-V-T & Cln Outs) INSULATION l rj ~ ~, ~~ -Water Supply .;e Bibs (bckflw pro. regd) -Slab (R10) -Wall (R-19) f rl; f ; ' + ~ .. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 City of Port Townsend Port otwnsend `WA 98366 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1319 57TH ST Parcel No: 972904301 Project: Issued: 5/19/98 Lot: Blook: BLD98-00049 Inspection Date Inspecto -Ceiling (R-30) -Baffles [{~/,1 VAPOR BARRIER DRYWALL NAILING .~ 1~ (3 -Walls -Ceiling FINAL ~ ' Insp-See Special Conditions Final-House Number I-Building I-Plumbing Final-Insulation Certificate Final-Vapor Barrier Cerl. J Final-Smoke Det. Througout Final -Building SPECIAL CONDITIONS /RESTRICTIONS 1 . TESC: Applicantlcontraetor shall install temporary erosion control measures as required during construction. Measures shall include but are not limited to installation of silt fencing and graveled construction entrance. The public right-of-way shall be kept clean. Tracking of mud and debris from the site will not be allowed. Failure to comply with this condition will result in all work on the site being stopped. Areas disturbed by construction activity which are not to be covered by permanent impervious surfaces (e.g., parking, walkways, driveways, porches) shall be landscaped or reseeded within seven days of reaching final grade. Once construction is completed, the site must be permanently stabilized with seeding, plantings, sodding, etc. Applicant is responsible far protection of adjacent properties. 2. Environmental air exhaust ducts must terminate outside the building 3' from property lines and 3' from openings into the building to minimize recirculation.Environmental air exhaust ducts must terminate outside the building 3' from property lines and 3' from openings into the building to minimize recirculation "`delete this line and enter condition text here'"' Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 City of Port Townsend Port o`wnaend tWA 98366 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1319 57TH ST Issued: 5!19198 Parcel No: 972904301 Lot: Block: Project: BLD98-00049 SPECIAL CONDITIONS! RESTRICTIONS 3. Smoke detectors (SD) are required throughout the house per the 1994 UBC: SD's in each sleeping room and in hallways/areas giving access to the sleeping area with a minimum of one on each floor. Inspection required. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. •5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. u Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3