HomeMy WebLinkAboutBLD98-039City of Port Townsend Water SVeet Port Townsentl, WA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME . Call 385-2294 For Inspection Site Address: 2344 RAINIER ST Parcel No: 955900007 Project: JAIME KOZELISKY 1112 S. JACOB MILLER ROAD PORT TOWN//SEND, WA 98368 4t/A(A~5 ~~W F~CAQG$ y~i~Vd -PROJECT DESCRIPTIO - Residential: Insta4 ;manufactured home r~ifh garage and porch. Issued: 5!5/98 Lot: Block: F'~RMIT # BLD98-00039 OWNE HAMILTON HEIGHTS LLC 2510 CREST AVE PORT TOWNSEND, WA 98368 City ContacC JLZ Construction TypelOcc UserCcc Load ?ype of work: NEW Construction Occupanry Type of use: SFR Type 1: SN Group I: R-3 .Load 1: 4 Census Category: 112 Type 2: Group 2: U-t Load 2: 1 Estimated Value: $20,577.64 Type 3: Group 3: toad 3: Zoning: ' St Code: PUD Type 4: Group 4: Loaa 4: i SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector Insp-See Special Conditions ~'~ FOUNDATION Insp-See Special Conditions ~,Z Insp-See Special Conditions ~/p Insp-See Special Conditions ~~ -Stem Wall TEMP EROSION & SDM'T CON -Forms Insp-See Special Conditions ~# -Reinforcement FOOTINGS -Anchor Bolts ~ Insp-See Special Conditions¢{,S- -Vents -Setbacks -Crawl Access -Footings -Alt BWP Holdown Hdwr ~E• Carlo/nor/ 7 -Forms SLAB -Reinforcement ~ j ~ ~ Insp-See Special Conditions Porch/Deck Bay Piers -Setbacks ~'ER -Forms Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 City of Port Townsend 848 Waterb"°" Port Townxml, WA 98388 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2344 RAINIER ST Issued: 5!5198 Parcel No: 95590D00T Block: Protect: PE~~M IT # gLD98-00039 Inspection Date Inspector Inspection Date Inspector -Slab -Alternate Braced Wall Panel -Reinforcement -Roof -Steel support piers -Attic Venting FLOOR FRAMING -Weather Resistive Barrier 5/Di~/~, Insp-See Special Conditions„~9 VAPOR BARRIER -Girders -Crawl Space - 6 Mil Poly -Positive Connection DRYWALL NAILING -Treated Wood to Concrete -Walls PLUMBING -Ceiling Insp-See Special Conditions~9 -Garage/House Occ. Separation Insp-See Special Conditions.~~d DRAINAGE Insp-See Special Conditions ~~ Insp-See Special Conditions #~9 Insp-See Special Conditions #~~„ -Per Master Plan Insp-See Special Conditions #~3 FINAL Insp-See Special Conditions ~~.e f Insp-See Special Conditions ~~ -Water Supply Insp-See Special Conditions ~Z>' -Hose Bibs (bckflw pro. regd) Fina{-House Number -Pipe Insulation. Final-Plumbing MECHANICAL Final-Mechanical/Heating Insp-See Special Conditions ~~5 Final-Smoke Detectors Insp-See Special Conditions fl/~ Final-Public Works Sign-Off -Duct Insulation Final -Electrical (L&I) -Whole House Fan Final -Building FRAMING Insp-See Special Conditions,¢f~ Insp-See Special Conditions ~/~ -Walls Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 City of Port Townsend water Street Port Townsend, WA 98369 Building and Community Development BUILDER'S PERMIT AND INSPECTION. RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2344 RAINIER ST IssuteDdt: 515/98 Parcel No: 955900007 PEf1MIT # Block: Project: BLD98-00039 SPECIAL CONDITIONS /RESTRICTIONS 1 . HOURS: Outdoor construction activities shall be limited to the hours of 7:30 a.m. to 6:00 p.m. Monday -Friday and prohibited on Saturdays, Sundays & national holidays. 2. Dust control measures shall include watering of the site, backfilling as soon as possible and sweeping impervious surtaces where soil may be tracked. Chemical dust suppressants shall not be used, 3. Trees greater than 12" in diameter ~ 4 feet above ground and more than 10' from the building :,ad shall be field marked far the contractor and not removed. 4. TESC: Erosion and sediment control measures to be installed on-site during construction per Hamilton Heights Master Plan and Department of Ecology Best Management Practices. 5. FOOTINGS: Applies to garage/porch only. 6. FOUNDATION: Applies to garage only. ~ SLAB: Reinforced concrete slab for home requies minimum 4 1/4" slab. ~8. FLOOR FRAMING: Applies to site-built porch only. 9. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required. 10. PLUMBING: Main shut-off valve to be installed in water supply piping prior to connection to home. Valve shall be full-flow type (gate or ball valve); minimum 3/4" diameter, same as supply pipe. 11 . PLUMBING: Freeze protection (insulation) required for water supply pipes outside and in crawl space. 12. PLUMBING: Pressure test required; water pressure at 100 psi for 15 minutes. 13. PLUMBING: Water heater pressure relief valve drain shall extend outside of skirting, with elbow down and terminate between 6" and 24" above ground. 14. PLUMBING: Horizontal runs in drainage system shall be sloped minimum 1/4" per foot. 15. MECHANICAL: Whole house exhaust fan timer shall be set to operate for 2 4-hour periods per day uless central exhaust fan is set to run continuously. 16. MECHANICAL: Dryer exhaust shall be vented to the outside. Extension into crawl space requires venting through skirting with no dips; follow dryer manufacturers instructions. Moisture exhaust duct shall not exceed total combined vertical and horizontal length of 14 feet with 2 90-degree elows. 17. FRAMING: All elements of alternate braced wall panel require inspection prior to cover. 18. FRAMING: Alteration insignia for garagelporch shall be posted on home at inspection time. 19. DRAINAGE: All water drains piped to outside shall drain away from home; ground to slope away from home for minimum 5 feet ~ 1/2" per foot. 20. FINAL: Pier supports and anchors per manufactured home installation manual require inspection prior to skirting. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 City of Port Townsend PoR Townsend `WA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD ?£ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2344 RAINIER ST Issued: s/5rss Parcel No: 955900007 PERMIT # Block: Project: BLD98-00039 SPECIAL CONDITIONS 1 RESTRICTIONS 21 . FINAUSKIRTING: No holes or gaps greater than 1/4" allowed in skirting. Crawl space ventilation per manufacturer's specs or 1!150 (13 req'd.}, located on at least two opposing sides to provide for cross ventilation. Crawl space access required: one (1) per section or as required by manufacturer; minimum 18" x 24". GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year.. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PUaNS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 Waterman &ICalx Building 1SI Quinry Street, Sui4 301 Part Townrend, WA 98368 Phone: 360J79-3208 Fn:360J79b923 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD98-00039R-1 Job Address: 2244 Rainier Street Total Occupant Load: Owner: Hamilton Heights LLC Issued: 2/19//99 Parcel Number; 955900007 Zoning: RR=II Type: V_N Occupancy: R-3/U-I Nature of Work: Engineered detail for 16"BWP Contractor: Same as Owner GENERAL coxnITIONS APPLY: SEPARATE PERMTTS REOUIItED: Framing (May be done at final) FINAL Final -Building ~.~,~ j ~,('~ GENERAL CONDITIONS • 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license, Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3, Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept Ca1148 hours before you dig far utility line locates 1-800-424-5555 Pagel oft Walernun Bc Kats BuOding I81 Quiery Street, Suite 301 Port Towwend, WA 98368 Phone: 360~79J208 Fax 360J79-6924 GENERAL CONDTTIONS free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent-shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection caI1385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Paget of 2 ~~