Loading...
HomeMy WebLinkAboutBLD98-035540 Water Street City of Port Townsend PoR Townsend, WA 9868 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4820 MAGNOLIA Parcel No: 951904001 Project: MATT VANDELEUR BARBARA VANDELEUR 1235 LANDES STREET Issued: 4/27198 YBLD98-00035 CRIST TRUSTEE ROBERT S SEATTLE FIRST NATIONAL BANK TRUSTEE 50% EACH -PROJECT DESCRIPTIO Residential -New Single Family Dwelling - 1981SF, 140SF unfinished den; 174SF porch; and 400SF garage. City Contact: JZ Construction TypelOcc UselGcc Load Type of work: NEW Construction Occupancy Type of use: SFR Type 1: SN Group is R-3 Load 1: 7 Census Category: 101 Type 2: Group 2: U-1 Load 2: 2 Estimated Value: $160,369.96 Type 3: Group 3: Load 3: Zoning: R-II 51 Cade: _ i YVe ~~ Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector, TEMP EROSION & SDM'T CON -Anchor Bolts I Insp-See Special Conditions ~ ~ -Vents ~p ~~'v FOOTINGS -Crawl Access ~ 3 -Setbacks ~ SLAB j j -Footings Insp-See Special Conditions 3 i i -Reinforcement -Monclithic Slab/Fdn j -Interior Footing ~ -Reinforcement -LIFER ~/~fa F~~ -Interior Footing ~! FOUNDATION -Anchor Bolts Insp-See Special Conditions .#Z FLOOR FRAMING -Stem Wall ~ Insp-See Special Conditions -Forms ~ -Girders inforcement -Joists (~ Call 48 hours before you dig for utility line locates 1-800-424-5555 c - Page 1 of 3 /', i~q a QY ~0~~ Tt'~~Nt'~S@t'~CI 840 Water Street ~,y X77 ~Y V V iYY ~i Port Townsend, Wq 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4820 MAGNOLIA Issued: 4127/98 Parcel No: 951904001 L n k: Project: 7-~'l1T ~ BLD98-00035 r Inspection Date I pector Inspection Date Inspector -Blocking -Attic Venting -Anchor Bolts & Washers -Windows: Egress -FDN Vents -Window U Value PLUMBING -Air Seal Insp-See Special Conditions ~~' -Fresh Air Intake (Window) -Rough-In (D-V-T & Cln Outs) -Door U Value -Water Supply -Rafter/Truss Pos. Conn. -Gas Supply -Fire Blocking ~ -Hose Bibs (bckflw pro. regd) -Weather Resistive Barrier ~/ ~/ -Pipe Insulation INSULATION ~ ~ ~ S ~; -Pressure Reduction Valve -Floor (R-t 9) -Water Heater -Ceiling (R-30) ' -18" A.F.F. -Baffles p s 9 -Seismic Restraint VAPOR BARRIER MECHANICAL -Paint Insp-See Special Conditions ~ ~ -Crawl Space - 6 Mil Poly -LPG Heater DRYWALL NAILING ltd --~r/~JG~~e•~ -Walls -Whole House Fan -Ceiling -Source Specific Fan -Garage/House Occ. Separation -Environmental Air Exhaust -Enclosed Space Under Stairs FRAMING FINAL Insp-See Special Conditions~f ~ Final-House Number -Walls Final-Plumbing -Engineered Shear Walls ? z~ ~ ~ j Final-Mechanical/Heating -Seismic Anchors Final-Vapor Barrier Cert. -Roof Final-Smoke Detectors Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 C~~y ~~ ~~ ~C3~l~S~r~d SfOWaterStreet '~v Port Townsend,. wA 983&8 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4820 MAGNOLIA Parcel No: 951904001 Project: Inspection Date Inspector Final-Public Works Sign-Off ,Final-LPG (Fire Dept.) Final -Electrical (L&I) SPECIAL CONDITIONS /RESTRICTIONS Issued: 4/27198 (IT ~- BLD98-00035 1 . TESC: ApplicanUcontractorto install and maintain temporary erosion control measures as required during construction. Tracking of mud and debris from the site to street will not be allowed. Failure to comply will result in stop work order. Other Best Management Practices may apply. 2. FOUNDATION: See approved engineered plans for holdown details. All elements of the engineered design roquire irs,;ection prior to cover. ~;. SLAB: See approved engineered plans for holdown details for garage monoslab. All elements of the engineered design require inspection prior to cover. 4. FLOOR FRAMING: Inspect crawl space PRIOR to decking. 5. PLUMBING: Pressure reducing valve required if water pressure > 80psi. 6. MECHANICAL: Whole house fan to be 100 - 150cfm ~ .25" w.g. and 1.5 sone rating. Enviromentaf duct terminus to be 3' from building openings. 7. FRAMING: See approved engineered plans for shear wall locations and nailing. All elements of the engineered design require inspection prior to cover. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 i