HomeMy WebLinkAboutBLD98-034r City of Port Townsend Port ownsendtWA 98368 ,' Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1540 47TH ST Parcel No: 101353003 Project: CRAIG JOHNSON 1721 KUHN ST P.O. BOX 968 -PROJECT DESCRIPTIO Residential -Construct new garage far parking & workshop City Contact: JLZ Type of work: GAR Construction Type of use: SFR Type 1: SN Census Category: 438 Type 2: Estimated Value: $30,000 00 Type 3: Zoning: R-II I SI Code: Type 4. Construction TypelOcc UselOcc Load Occupancy Group 1: U-1 Load 1: Group 2: Load 2: Group 3: Load 3: Group 4: Load 4: 5 SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Ilnspector Inspection Date Inspect iTEMP EROSION & SDM'T CON I FOUNDATION ~_ I ilnsp-See Special Conditions Insp-See Special Conditions j 1I Silt Fence Insp-See Special Conditions I -Drive Off Mat ' -Stem Wall '-Sweep Paved Surfaces -Forms ~i i '.DEMOLITION -Reinforcement ~ (~ Insp-See Special Conditions -Anchor Bolts .,FOOTINGS ' /~ ~ !1' -Alt BWP Holdown Hdwr ! i acks Setb SLAB ^ '`~ Footings -Forms rcement -Reinfo ~ Insp-See Special Conditions FRAMING Insp-See Special Conditions ~~ I, 1 -'I-ER ~ ~ Insp-See Special Conditions ~ i Issued: 3116198 -7 CHEBUHAR CHARLES POBOX88 MONROE, WA 982720088 J Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 City of Port Townsend Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1540 47TH ST Parcel No: 101353003 Project: l Inspection j Date Inspector -Walls I -Alternate Braced Wall Panel -Roof ~ I-RaftedTruss Pos. Conn. I-Weather Resistive Barrier DRYV1lALL NAILING -Walls : -Ceiling -Interior Braced Wall Panels i '..FINAL ~~ Final-Public Works Sign-Off 'Final -Building ~, J 3 3 L s 'i SPECIAL CONDITIONS /RESTRICTIONS 1 . TSEC: ApplicanUcontractor to install temporary erosion control measures as required during construction.Tracking of mud and debris from the site to street will not be allowed. Failure to comply will result in stop work order. Other Best Management Practices may apply. 2. DEMOLITION: All construction debris to be deposited in approved areas in accordance with local, state and federal laws. 3. FOUNDATION: See attached prescriptive rebar requirements. 4. FOUNDATION: Garage wall brace design requires 4 ABWP's. Holdowns must be on site and perferably installed in wall prior to inspection. Note: Check Simpson catalog for required distance from foundation corner to holdown placement. 5. SLAB: Non-structural; no inspection required. 6. FRAMING: All elements of ABWP's require inspection prior to cover. 7. FRAMING: Prior to Framing Inspection, permitee to contact Public Works to determine if Minor Improvement Permit (MIP) is required for new driveway configuration where it meets R-O-W. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 540 Water Street Port Townsend, WA 99J66 ~. Issued: 3116/98 Lo ~ loc: t'l- ~. BLD98-00034 City of Port Townsend Port ownsend,fWA 98366 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1540 47TH ST Parcel No: 101353003 Project: Issued: 3!16198 GENERAL CONDITIONS Lo : Blo c Pt~M K ~ BLD98-00034 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building pepartment within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 City of Port Townsend 540 Water Street Port Townsend, WA 98368 Building and Community Development • BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1540 47TH ST Parcel No: 101353003 Project: -CONTRACTOR/OWN E CRAIG JOHNSON 1721 KUHN ST P.O. BOX 968 PORT TOWNSEND. WA 98368 -PROJECT DESCRIPTIO Rev No 1: Tension-tie slab to stem walls per approved plans. City Contact: RNS Type of work: GAR Construction Type of use: SFR Type 1: 5N Census Category: 438 Type 2: Estimated Value: $30,000.00 Type 3: Zoning: R-II Type 4: SI Code: Group 2: Load 2: Group 3: Load 3: Group 4: Load 4: 5 SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector SLAB -Reinforcement GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. v Issued: 7128198 ~- BLD98-34R1 ELENOR CHEBUKHAR 1543 ADMIRALTY AVE PORT TOWNSEND, WA 98368 Call 48 hours before you dig for utility line locates 1-800-424-5555 Construction TypelOcc Use/Occ Load Occupancy Group 1: U-1 Load 1: Page 1 of I i •