Site Address: 2575 SHERIDAN AVE Issued: 3/27/98
Parcel No: 93170052 Lot: Block:
Pro;e«: PERMIT # BLD98-00031
-CONTRACTOR/OWNE
JAIME KOZELISKY
1112 S. JACOB MILLER ROAD
PORT TOWNSEND, WA 98368
WA%US Qi.?~ e:kY 7~~98
OWNER
GARY/CANNA WILES
2510 GRANT PLACE
PORT TOWNSEND, WA 98368
-PROJECT DESCRIPTIO
Residential -Place 1404 sq, ft. manufactured home with 48 sq. ft. in porches; add 220 sq. ft. carport.
City Contact: JLZ Construction TypelOcc UselOcc Load
Type of work: NEW Construction Occupancy
Type of use: SFR Type 1: 5N Group 1: R-3 Load 1: 5
Census Category: 112 Type 2: Group 2: U-1 Load 2: 1
Estimated Value: 521,152.68
Zoning:
R-II Type 3' Group 3: Load 3:
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date ' Inspecto
Insp-See Special Conditions ~~ Insp-See Special Conditions ~}
TEMP EROSION & SDM'T CON Insp-See Special Conditions ~,S J 4
Insp-See Special Conditions.#~ Insp-See Special Conditions ~~
,FOOTINGS ~ ~ ~~ (', I sp-See Special Conditions
j-Setbacks ~ I -Water Supply
~-Reinforcement -Hose Bibs (bckflw pro. regd)
SLAB -Pipe Insulation
-Setbacks MECHANICAL
-Forms ~ Insp-See Special Conditions ~$
-Monolithic Slab/Fdn ~ ~ ,r, Insp-See Special Conditions ff9
-Reinforcement r-- ~ ~ -Duct Insulation
UMBING
~ -Whole House Fan
,rSee Special Conditions ~3
L FRAMING
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
City of Port Townsend
Building and Community Development
616 Water Street
Port Townsend, WA 98368
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2575 SHERIDAN AVE Issued: 3/27/98
Parcel No: 93170052 ot: Block:
Protect: PE~MlT ~# B~D98-ooos~
Inspection Date Inspector
Insp-See Special Conditions #~~
Insp-See Special Conditions ~ ~~
-Walls
-Ceiling
-Roof
-RatteNTruss Pos. Conn. g
VAPOR BARRIER
-Crawl Space - 6 Mil Poly
DRAINAGE
Insp-See Special Conditions ~~a
FINAL
Insp-See Special Conditions #~3 $ ~ j/
Insp-See Special Conditions ~~ -
Final-House Number
Final-Plumbing
Final-Mecha nica IlHeating
Final-Smoke Detectors
Final-Public Works Sign-Off 1
Final -Electrical (L81)
Final -Building
SPECIAL CONDITIONS /RESTRICTIONS
1 . ALTERATIONS: Any partially or fully supported attachments to the home require an alteration
permit and inspection by Labor and Industries.
Call 48 hours before you dig for utility line locates
1-800-424-5555
1
Page 2 of 4
City of Port Townsend Port orwnsendtWA 96168
Building and Community Development.
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2575 SHERIDAN AVE Issued: 3/27/98
Parcel No: 93170052 Lot: Block:
Project: P~RMlT # BLD98-00031
SPECIAL CONDITIONS /RESTRICTIONS
2. TESC: TESC: ApplicanUcontractorsholl install temporary erasion control measures as
required during construction. Measures shall include but are not limited to installation of silt
fencing and graveled construction entrance. The public right-of-way shall be kept clean.
Tracking of mud and debris from the site will not be allowed. Failure to comply with this
condition will result in all work on the site being stopped. Areas disturbed by construction
activity which are not to be covered by permanent impervious surfaces (e.g., parking,
walkways, driveways, porches) shall be landscaped or reseeded within seven days of reaching
final grade. Once construction is completed, the site must be permanently stabilized with
seeding, plantings, sodding, etc. Applicant is responsible for protection of adjacent properties.
3. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
4 . PLUMBING: Main shut-off valve to be installed in water supply piping prior to connection to
home. Valve shall be full-flow type (gate or vall valve); minimum 3/4" diameter, same as
supply pipe.
5. PLUMBING: Freeze protection (eg. insulation) required for water supply pipes outside and in
crawl space.
6. PLUMBING: Water heater pressure relief valve drain shall extend outside of skirting, with
elbow down and terminate between 6" and 24" above ground.
7. PLUMBING: Horizontal runs in drainage system shall be sloped minimum 114" per foot.
8. MECHANICAL: Whole house exhaust fan timer shall be set to operate for 2 4-hour periods per
day unless central exhaust fan is set to run continuously.
9. MECHANICAL: Dryer exhaust shall be vented to the outside. Extension into crawl space
requires venting through skirting with no dips; follow manufacturer's instructions, Moisture
exhaust ducts shall not exceed total com rued vertical and horizontal length of 14 feet with 2
90-degree elbows.
10. FRAMING: Framing inspection required for carport.
11 . FRAMING: If carport is not fully self-supporting or if roof of home is modified, an alteration
permit and inspection is required by Labor and Industries. Plans are unclear as to whether
porches are factory-built orsite-built. Site-built porches also require L & I review and
inspection.
12. DRAINAGE: All water drains piped to outside shall drain away from home; ground to slope
away from home for minimum 5 feet ~ 112" per foot.
13. FINAL: Pier supports and anchors per manufactured home installation manual require
inspection prior to skirting.
14. FINAUSKIRTING: No holes or gaps greater than 1/4" allowed in skirting. Crawl space
ventilation per manufacturer's specs or 1!150, located on at least two opposing sides to provide
for cross ventilation. Crawl space access required: one (1) per section or as required by
manufacturer; minimum 18" x 24".
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend ~wo`W~s a`wnes3ea
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2575 SHERIDAN AVE Issued: 3/27198
Parcel No: 93170052 Lot: Block:
Project: PER~.~lIT # BLD98-00031
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE. WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
~.
Page 4 of 4
City of Port Townsend Port ownsendiWA 98968
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2575 SHERIDAN AVE Issued: 7/24/98
Parcel No: 93170052 Lot: Block:
Project: BLD98-31 R1
-~ONTRACTOR/OWNE
GARY/CANNA WILES
WNE
GARY/I~1NNA WILES
Revision to building permit #BLD98-00031
City Contact: JGE Construction TypelOcc UselOcc Load
Type of work: NEW Construction Occupancy
Type of use: SFR Type 1: Group 1: Load 1:
Census Category: 112
Type 2:
Group 2: Load 2:
Estimated Value:
Type 3:
Group 3: Load 3:
Zoning:
. Type 4: Group 4: Load 4:
SI Code:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
City of Port Townsend 5°U WaterStre°`
Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2575 SHERIDAN AVE Issued: 7~24/9a
Parcel No: 93170052 Lot:
Projecl:
Block:
BLD98-31 R1
Call 48 hours before you dig for utility line locates
1-800-424-5555