HomeMy WebLinkAboutBLD98-028_. City of Port Townsend Building and Community Development 340 Water Street Port Townsend, WA 98388 ,~ BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Addres .1132 20TH Parcel No: 94 Project: KCCHA 9265 BAYSHORE DRIVE SILVERDALE, WA 98383 Issued: 5119/98 Lot: Block: PERMIT # BLD98-00028 WNE MOSIER DAVID 1186 20TH STREET PORT TOWNSEND, WA 98368 Residential: Construct 1300 sq. ft. home with 297 sq. ft. garage and 121 sq. ft. porch. City Contact: JZ Type of work NEW Type of use: SFR Census Category: 101 Estimated Value: $703,939.00 Zoning: R-II SI Code: Construction Type/Occ Use/Occ Load Construction Occupancy Type 1: SN Group t: R-3 Load 1: Type 2: Group 2: U-1 Load 2: Type 3: Type 4: Group 3: Load 3: Group 4: load 4: 4 SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector Ilnsp-See Special Conditions + -Stem Wall TEMP EROSION & SDM'T CON -Forms Insp-See Special Conditions ~ ~ j -Reinforcement FOOTINGS j -Anchor Bolts -Setbacks ~ -Vents 4, ~ Q -Footings -Crawl Access b -Forms -Beam Pockets E, -Reinforcement -Alt BWP Holdown Hdwr ~ g -Interior Footing FLOOR FRAMING ' -Porch Bay Piers -Girders - r -LIFER ~~~ ~- n -Joists FOUNDATION ?an " ,~ -Blocking ~p-See Special Conditions ~ -Shield Under Posts ,' Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 City off' Poa~ Tc~wa~~e~d 640 WaterStree! Pori Townsend, WA 98388 . s Building and Community Development ' BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1132 20TH. Issued: 5nsi9s Parcel No: 948308903 Lot: Block: Protect: PERMIT # BLD98-00028 Inspection Date Inspector Inspection Date Inspect r -Int. Braced Wall Supports -Window U Value -Positive Connection -Window Safety Glazing -Girder to Concrete -Air Seal -Beam Pockets -Fresh Air Intake (Window) -Treated Wcod to Concrete -Door U Value -Anchor Bolts & Washers -RafterlTruss Pos. Conn. -FDN Vents -Fire Blocking PLUMBING -Weather Resistive Barrier ~ ZQ Insp-See Special Conditions INSULATION -Raugh-In (D-V-T & Cln Outs) -Floor (R-30) -Water Supply -Under WH (R-10) -Hose Bitu (bckflw pro. regd) Zf/ d/ -Wall (R-19) ~t~ ~,~~/ ~ -Pipe Insulation -Ceiling (R-38) -Water Heater -Baffles ~ ~; ~r -Seismic Restraint VAPOR BARRIER MECHANICAL -Paint -Whole House Fan -Crawl Space - 6 Mil Pofy -Source Specificfan DRYWALL NAILING -Environmental Air Exhaust -Walls FRAMING -Ceiling ~~ -Walls -Interior Braced Wall Panels ~! ~ -Alternate Braced Wall Panel -GaragelHouse Occ. Separation J ~+ .e ~ -Blk'g for GWB IBW Panels DRAINAGE -Ceiling Insp-See Special Conditions ~.{'S -Roof FINAL -Attic Venting Insp-See Special Conditions ~' -Windows: Egress Insp-See Special Conditions Call 48 hours before you dig for utility line locates 1-800-424-5555 1 Page 2 of 4 City of Port Townsend aot TaownserW, WA 98388 Building and Community Development BUI~.DER'S PERMIT AND INSPECTION RECORD THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1132 20TH Parcel No: 948308903 Project: Inspection Date Inspector Final-House Number Final-Plumbing Final-Mechanical/Heating Final-Insulation Certificate Final-Vapor Barrier Cert. Final-Smoke Detectors Final-Public Works Sign-Off Final -Building '",/~ 7~C' ~ •PECIAL CONDITIONS ! RESTRICTIONS Issued: 5119/98 Lot: Block: PERMIT # BLD98-00028 1 . ALL ELEMENTS OF ALTERNATE BRACED WALL PANELS REQUIRE.INSPECTION PRIOR TO COVER. 2. TESC: ApplicanUcontrador shall install temporary erosion control measures as required during construction. Measures shall include but are not limited to installation of silt fencing and graveled construction entrance: The public right-of-way shall be kept clean. Tracking of mud and debris from the site will not be allowed. Failure to comply with this condition will result in all work on the site being stopped. Areas disturbed by construction activity which are not to be covered by permanent impervious surtaces (e.g., parking, walkways, driveways, porches) shall be landscaped or reseeded within seven days of reaching final grade. Once construction is completed, the site must be permanently stabilized with seeding, plantings, sodding, etc. Applicant is responsible for protection of adjacent properties. 3. FOUNDATION: Crawl girder end post/fdn. wall requires positive connection or use beam pocket. 4. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required. 5. DRAINAGE: Infiltration per approved master plan dated 9/16!97 by ADA Engineering. Contact the Engineering Department for inspection. 6. FINAL: Protective barrier required for garage appliances located in vehicle path of travel. (UMC 308.1) 7. FINAL: Contact the Engineering Department for inspection and approval of infrastructure requirements prior to scheduling final inspection. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Lr ~ ly ~~ ~ ~ ~ T ~ ~ S ~. n ~ aor! Townsend,~wa asses Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD ;i THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1132 20TH Issued: 5H 9/98 Parcel No: 948308903 Lot: Block: Pro;ed: PERMIT # BLD98-00028 GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy: 4. All building perTnits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. f~ Call 48 hours before you dig for utility line locates 1-800-424-5555 P~eaora