HomeMy WebLinkAboutBLD98-025? City of Port Townsend ~wovnsend`wasasca
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1110 20TH ST
Parcel No: 948308903
Project:
-CONTRACTOR/OWNE
ItCCHA
9265 BAYSHORE DRIVE
SiLVERDALE, WA 98383
Issued: 5/21198
t Block:
PERMIT # BLD98-00025
OWNE
PATRICIA FINNIGAN
1110 - 20TH STREET
PORT TOWNSEND, WA 98368
-PROJECT DESCRIPTIO
Residential: Construct 1232 sq. ft. home with 320 sq. ft. garage, entry parch and patio.
City Contact: JZ Construction TypUOcc UselOcc Load
Type ofwork: NEW Construction Occupancy
Type of use: 8FR Type 1: SN Group 1: R-3 Load 1: 4
Census Category: 101 Type 2: Group 2: U-1 Load 2: 1
Estimated Value: $100,209.28
Type 3: Group 3: Load 3:
Zoning: R-II
.
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~ -Stem Wall
TEMP EROSION & SDM'T CON -Forms
Insp-See Special Conditions a. -Reinforcement
FOOTINGS -Anchor Bolts i
~-Setbacks -Vents ~~ '~`~ ~ Y (,~
-Footings -Crawl Access 1~T~~,~L ~
-Forms -Beam Pockets
-Reinforcement -Alt BWP Haldown Hdwr ~- ~, ~ ~~
-Interior Footing FLOOR FRAMING
-Porch Bay Piers Insp-See Special Conditions ~ ,
-LIFER ~ C~ -Girders ~ ~.1
FOUNDATION ,~ /'~ -Joists
a-See Special Conditions ~ 3 -Blocking
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
City ®~ i. Oi 7L ToYY~J~61~ 540 WaownsendWA 88368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
. Call 385-2294 For Inspection
Site Address: 1110 20TH ST Issued: 5/21/98
Parcel No: 948308903 Block:
Pro;ect: PE~M1T # gLD98-00025
Inspection Date Inspector Inspection Date Inspect
-Shield Under Posts ~ rf ~ ~ -Windows: Egress
-Positive Connection ~' -Window U Value
-Girder to Concrete -Window Safety Glazing
-Beam Pockets N -Air Seal
-Treated Wood to Concr e ~ 7 !~8 nob ~ -Fresh Air Intake (Window)
-Anchor Bofts & Washers -RafterlTruss Pos. Conn.
-FDN Vents -Fire Blocking
PLUMBING IZ -Weather Resistive Barrier
Insp-See Special Conditions INSULATION
-Rough-In (D-V-T & Cln Outs) -Floor (R-30)
i
-Water Supply -Under WH (R-10)
-Hose Bibs (bckflw pro. regd) -Wall (R-79) 7i (ld
-Pipe Insulation -Ceiling (R-38)
-Water Heater -Baffles
-Seismic Restraint VAPOR BARRIER
MECHANICAL -Paint
Insp-See Special Conditions ~(P -Crawl Space - 6 Mil Poly
-Duct Insulation DRYWALL NAILING Z
-Whole House Fan ~ -Walls
-Source Specific Fan -Ceiling
-Environmental Air Exhaust -Interior Braced Wall Panels
FRAMING 2 ~ q -Garage/House Occ. Separation
-Walls -Enclosed Space Under Stairs
-Alternate Braced Wall Panel FINAL
-Ceiling Insp-See Special Conditions
-Roof Final-House Number
-Attic Venting Final-Plumbing
Call 48 hours before you dig for utility fine locates
1-800-424-5555
1
J
J
Page 2 of 3
pity of ~'ar~ ~t~w~s~r~d
Building artd Community Development
6d0 Water Street
Port Townsend, WA 88368
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1110 20TH ST Issued: 5121198
Parcel No: 948308903 Lpot: Block:
Project: PERM~~ ~ BLD98-00025
Inspection Date :' Inspector
Final-Mechanical/Heating
Final-Insulation Certificate
Final-Vapor Barrier Cert. /
Final-Smoke Detectors ~ i
LFinal-Public Works Sign-Off ' ,
Final -Building ~ ~~./~Z ~~ Y
SPECIAL CONDITIONS /RESTRICTIONS
t . ALL ELEMENTS OF BRACED WALL PANELS REQUIRE INSPECTION PRIOR TO COVER.
.2. TESL: Applicant to install erosion control measures per attached details (see Minor
Improvement Permit) and per approved engineered drainage plan.
3. FOUNDATION: Crawl girder end post/fdn. wall requires positive connection or use beam
pocket (3" bearing, typ.).
4. FLOOR FRAMING: Crawl girder end posUfdn, wall requires positive connection or use beam
pocket.
5. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
6. MECHANICAL: Protection of appliances required when located in garage path-of-travel.
7. FINAL: Contact the Engineering Office far inspection and approval of Public Works
requirements prior to scheduling final inspection.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
Z. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call far at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
\J
Call 48 hours before you dig for utility line locates
1-800-424-5555