Loading...
HomeMy WebLinkAboutBLD97-197City of Port Townsend .P n ownsendeWA 98368 ' Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4779 MASON ST Parcel No: 951904113 Project: -CONTRACTOR/OWNE ROBERT FITZPATRICK 4606 MAGNOLIA STREET PORT TOWNSEND, WA 98368 Issued: 12!30/97 Lot: Block: PERMIT # BLD97-00197 OWNE B & D VENTURES P- O- BOX 1466 PORT TOWNSEND, WA 98368 Residential:~Construct new house (1850 sq. ft.) with 470 sq. ft. garage, porch and decks. City Contact JZ ConstruMion TypelOcc UselOcc Load Type of work: NEW Construction Occupancy Type of use: SF Type t: SN Group 1: R-3 Load 1: 6 Census Category: 101 Type 2: Group 2: U-1 Load 2: 2 Estimated Value: $152,163.14 Type 3: Group 3: Load 3: Zoning: R-1 51 Code: Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector Insp-See Special Conditions ~~ -LIFER TEMP EROSION & SDM'T CON FOUNDATION Insp-See Special Conditions#~, Insp-See Special Conditions .o-'3 -Silt Fence Insp-See Speciat Conditions ~prf -Drive Off Mat -Stem Wall -Sweep Paved Surtaces -Forms FOOTINGS -Reinforcement -Setbacks -Anchor Bolts -Footings -Vents -Forms -Crawl Access -Reinforcement -Lat. Restraint Holdown Hdwr -Interior Footing -Alt BWP Holdown Hdwr ~Orch Bay Piers FLOOR FRAMING r U Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 5 City Of Port -~OVNt7S@t7C~ 540 Water Street L YY ~7 .Port Townsend, WA 98368 t Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4779 MA50N ST Issued: 12/30/97 Parcel No: 951904113 Lot: Block: Protect: PERMIT # BLD97-00197 Inspection Date Inspector Inspection Date Inspector Insp-See Special Conditions ~,E~- Insp-See Special Conditions ~~o ~ Insp-See Special Conditions #~~ Insp-See Special Conditions ~~~ -Joists Insp-See Special Conditions ~/a -Blocking Insp-See Special Conditions #~3 -Int. Braced Wall Supports Insp-See Special Conditions #~ -Positive Connection -Walls -Treated Wood to Concrete -Engineered Shear Walls -Anchor Bolts 8 Washers -Alternate Braced Wall Panel JT (~ -FDN Vents ~ l ~ -Blk'g for GWB IBW Panels PLUMBING -Seismic Anchors Insp-See Special Conditions .~E -Ceiling -Rough-In (D-V-T & Cln Outs) -Roof -Water Supply -Attic Venting -Gas Supply -Windows: Egress -Hose 6' s (b w Qroy regd) ~ S ~ -Window U Value -Pipe hisu1atio ~ -Window Safety Glazing -Water Heater -Air Seal -Seismic Restraint -Fresh Air Intake (Window) MECHANICAL -Door U Value -LPG Heater -RafterlTruss Pos. Conn. -Combustion Air -Fire Blackin -Whole House Fan -Wea her Re g 'er S -Source Specific Fan 3 S IN$ULATIOPt, -Environmental Air Exhaust Insp-See Speci 1 FRAMING -Floor (R-30) Insp-Se,~,Spe ' I o i ions ~8 -Under WH (R-10) ~~ f},p~?> Insp-See Spec l o itlons ,~9 -Wall (R-19) Call 48 hours before you dig for utility line locates 1-800-424-5555 I f 1 J Page 2 of 5 City of Port Townsend ,Port ownsendeWA 98366 Building and Community Development i BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4779 MASON ST Parcel No: 951904113 Project: Inspection Date Inspector -Ceiling (R-38) -Baffles S 1~ ` (~' VAPOR BARRIER -Paint 'f 6 -Crawl Space - 6 Mil Poly DRYWALL NAILING Insp-See Special Conditions ,~~~ -Walls -Ceiling -Interior Braced Wall Panels arage/House Occ. Separation ~ (8 Cf (mil FINAL ~ ~BS Final-House Number Final-Plumbing Fina I-Mechanical/Heating Final-Insulation Certificate Final-Vapor Barrier Cert. Final-Smoke Detectors Final-Public Works Sign-Off Final-LPG (Fire Dept.) Final -Building Issued: 12/30/97 Lot: PERMIT # SPECIAL CONDITIONS /RESTRICTIONS Block: BLD97-00197 1 . ALL ELEMENTS OF BRACED WALL PANELS (BWP) REQUIRE INSPECTION PRIOR TO COVER. lam I Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 5 City of Port Townsend .P T w~~~d wneasea Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD _ THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME • Call 385-2294 For Inspection Site Address: 4779 MASON ST Issued: 12/30/97 Parcel No: 951904113 Lot: Block: Project: PERMIT # BLD97-00197 SPECIAL CONDITIONS !RESTRICTIONS 2. TESC: Applicant/contractorsholl install temporary erosion control measures as required during construction. Measures shall include but are not limited to installation of silt fencing and graveled construction entrance. The public right-of-way, specifically Mason Street, shall be kept clean. Tracking of mud and debris from the site will not be allowed. Failure to comply with this condition will result in all work on the site being stopped. Areas disturbed by construction activity which are not to be covered by permanent impervious surtaces (e.g., parking, walkways, driveways, porches) shall be landscaped or reseeded within seven days of reaching final grade. Once construction is completed, the site must be permanently stabilized with seeding, plantings, sodding, etc. Applicant is responsible for protection of adjacent properties. 3. FOUNDATION: See Sheet 516 for STHD holdown locations. 4. FOUNDATION: See Sheet 5/6: 7/16" OSB w/ 6d nails @ 6" o.c. edges and 12" o.c. field required when wood fdn. wall is under or within 4' of braced walls. 28" CS18 Simpson strap tie down detail required ~ 4' o.c. for non-braced wood fdn. walls. 5. FLOOR FRAMING: See Sheet 4/6 for engineering: continuous blocking between joists required where interior braced wall panels (IBWP) run perpendicular to joists. Doubled joists required under IBWP running parallel to joists. 6. FLOOR FRAMING: See page 1 of General Notes in engineering design talcs regarding framing. 7. PLUMBING: If water pressure exceeds 80 psi pressure reducing valve is required. 8. FRAMING: See General Notes in engineered design talcs re: wall framing. 9. FRAMING: See Sheet 616 for header sizes. 10. FRAMING: See Sheet 4/6 for braced wall panel details e.g., block all panel edges, bottom plate nailing, etc. 11 . FRAMING: Minimum .60 U-factor required for windows with efficiency of heating appliance unknown. 12. FRAMING: See Sheet 4/6, braced wall Tine between dining room/foyer and living room, far solid 2 x 6 blocking requirement between bottom chords of trusses for drag strut. 13. ROOF FRAMING: Engineered truss plan required on-site ~ inspection time. Top chord members to be sized for 30 psf snow load per engineering. 14. ROOF FRAMING: Exterior wall-to-roof connections: Simpson H-1 w/ 8d nails typical each rafter or truss. Install Simpson CS18 tie straps over ridges where rafters are used ~ 48" o.c. spacing. Use 6 10d nails per tie strap per engineering; see sheet 4/6. 15. INSULATION: Values on plans are higher than those required for compliance (see WSEC non-electric heat application). 16. DRYWALL: See Sheet 4/6 for IBWP locations; 5d nails ~ 4" o.c. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 5 City of Port Townsend 640 Water Street . Port Townsend, WA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4779 MASON ST Parcel No: 951904113 Project: GENERAL CONDITIONS Issued: 12/30/97 Lot: Block: PERMIT # aLD97-00197 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 5 of 5