HomeMy WebLinkAboutBLD97-187I~
4
City of Port Townsend P ~ o`W~Send, WA 96166
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
• THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4910 MAGNOLIA ST
Parcel No: 951904004
Project:
TERHUNE HOMES
PO BOX 97
POULSBO, WA 98370
Issued: 1/15/98
Lot: 5, 6 Block: 40
P p~ll- # BLD97-00187
ROBERT CRAMER
4601 COLUMBIA STREET
VANCOUVER, WA 98663
Residential: Construct single family residence (1733 sq. ft.) with 48D.5 sq. ft. garage, porch and deck.
City Contact: JLZ ConstruMion TypelOcc Use/Occ Load
Type of work: NEW Construction Occupancy
Type of use: SF Type 7: SN Group 1: R-3 Load 1: 6
Census Category: 107 Type 2: Group 2: U-t Load 2: 2
Estimated Value: $158,402.59
Type 3: Group 3: Load 3:
Zoning: R-I
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~~ -Porch/Deck Bay Piers
Insp-See Special Conditions #~ - FE " ~~'
TEMP EROSION & SDM'T CON FOUNDATION ~, •~ ~ / ~,
Insp-See Special Conditions #~ Insp-See Special Conditions ~3
-Silt Fence -Stem Wall
-Drive Off Mat -Forms
-Sweep Paved Surtaces -Reinforcement
FOOTINGS 2•~ °rz ,~ ~~; -Anchor Bolts
-Setbacks -Vents
-Footings -Crawl Access
-Forms -Beam Pockets
-Reinforcement -Alt BWP Holdown Hdwr
tenor Footing FLOOR FRAMING [( ~ ~ ~5
Call 48 hours before you dig for utility line locates J~j~:
1-800-424-5555 ~~~•
Page 1 of 4
City of Port Townsend 54U Water Street
Port Townsend, WA 88366
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME '•
Call 385-2294 For Inspection
Site Address: 4910 MAGNOLIA ST Issued: 1115/98
Parcel No: 951904004 Lot: 5, Block: 40
Protect: PERN~IT # BLD97-00187
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~ FRAMING
-Girders -Walls
-Joists -Alternate Braced Wall Panel
-Blocking -Ceiling
-Int. Braced WaII Supports -Roof
-Positive Connection -Attic Venting
-Girder to Concrete -Windows: Egress
-Beam Pockets -Window U Value
-Treated Wood to Concrete -Window Safety Glazing
-Anchor Bolts & Washers -Air Seal
-FDN Vents -Door U Value
PLUMBING -Rafter/Truss Pos. Conn.
Insp-See Special Conditions #S' -Fire Blocking
-Rough-In (D-V-T & Cln Outs) -Weather Resistive Barrier ~'
-Water Supply INSULATION
-Gas Supply -Floor (R-19)
-Hose Bibs (bckflw pro. regd) +-~ ~ -Under WH (R-10)
-Pipe Insulation -Wall (R-19)
-Pressure Reduction Valve -Ceiling (R30)
-Water Heater -Baffles c`
-18" A.F.F. VAPOR BARRIER
-Seismic Restraint -Paint
MECHANICAL -Crawl Space - 6 Mil Poly
-Duct Insulation y DRYWALL NAILING
-Whole House Fan -Walls
-Source Specific Fan -Ceiling
-Environmental Air Exhaust -Interior Braced Wall Panels
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
City of Port Townsend Port wnsend eWA 98968
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION 51TE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4910 MAGNOLIA ST
Parcel No: 951904004
Project:
Inspection Date Inspector
-Garage/House Occ. Separation
FINAL ~S- $ /~ ~,
Final-House Number
Final-Plumbing
Final-Mechanical/Heating
Final-Insulation Certificate
Final-Vapor Barrier Cert.
Final-Smoke Detectors
Final-Public Works Sign-Off
Final-LPG (Fire Dept.)
"''seal -Building
SPECIAL CONDITIONS /RESTRICTIONS
\ Issued: 1/15/98
Lot: 5, 6
PERMIT #
Block: 40
BLD97-00187
1 . SETBACKS: 20' setback required at front and rear yards for structures or elements (e.g.,
guardrails) which exceed a height of 30" above grade.
2. ALL ELEMENTS OF BRACED WALL PANELS (BWP) REQUIRE INSPECTION PRIOR TO
COVER.
3. TESC: Applicant/contractorsholl install temporary erosion control measures as required
during construction. Measures shall include but are not limited to installation of silt fencing and
graveled construction entrance. The public right-of-way shall be kept clean. Tracking of mud
and debris from the site will not be allowed. Failure to comply with this condition will result in
all work on the site being stopped. Areas disturbed by construction activity which are not to be
covered by permanent impervious surtaces (e.g., parking, walkways, driveways, porches) shall
e landscaped or reseeded within seven days of reaching final grade. Once construction is
completed, the site must be permanently stabilized with seeding, plantings, sodding, etc.
Applicant is responsible for protection of adjacent properties.
4. FDN: HPAHD22 holdowns speed on plans require 8" foundation wall.
5. FLOOR FRAMING: Interior Braced Wall Panels (IBWP) require double joists under.
6. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend Po T wnsend, WA 88368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4910 MAGNOLIA ST Issued: 1/15198
Parcel No: 951904004 Lot: 5, 6 Block: 40
Protect: PERMIT # BLD97-00187
GENERAL CONDITIONS
A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 or 4