HomeMy WebLinkAboutBLD97-184City of Port Townsend Port ownsendtWA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1205 29TH ST Parcel No: 957901201 Project: -CONTRACTOR/OWNE WILSON CONSTRUCTION 240 MOA HILL ROAD PORT TOWNSEND, WA 98388 -PROJECT DESCRIPTIO Single Family Residence: Remodel & Addition City Con[act: JLZ Type of work: ADD Construction Type of use:. SF Type 1: SN Census Category: 101 Type 2: Estimated Value: $19,315.06 Type 3: Zoning: R-II Type 4: 51 Code: Construction TypelOcc UselOcc Loatl Occupancy Group 1: R-3 Load 1: Group Z: Load 2: Group 3: Load 3: Group 4: load 4: 4 SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date ' Inspector Inspection Date Inspector Insp-See Special Conditions -Crawl Access DEMOLITION FLOOR FRAMING Insp-See Special Conditions -Joists FOOTINGS -Anchor Bolts & Washers -Setbacks -FDN Vents I-Footings PLUMBING -Reinforcement -Rough-In (D-V-T ~ Cln Outs) !-Porch/Deck Bay Piers -Water Supply FOUNDATION -Gas Supply -Stem WaII -Hose Bibs (bckflw pro. regd) -Reinforcement -Pipe Insulation -Anchor Bolts -Pressure Reduction Valve ents -Water Heater Issued: 1130/98 ~ BLD97-00184 MATT OLSON 1205 29TH PORT TOWNSEND, WA 98388 Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 0( 3 City of Port Townsend Port otwnsend tWA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Cal{ 385-2294 For Inspection Site Address: 1205 29TH ST Parcel No: 957901201 Project: Inspection Date Inspector Inspection Date inspector -Seismic Restraint Final-Plumbing MECHANICAL Final-MechanicaUHeating -LPG Heater Final-Vapor Barrier Cert. (-Source Specific Fan Final-Smoke Det. Througout FRAMING Final-LPG (Fire Dept.) -Walls Final -Building -Roof '-Attic Venting -Window Safety Glazing '-Air Seal ~ ~ -Door U Value i ~-Rafter/Truss Pos. Conn. -Weather Resistive Barrier INSULATION -Floor (R-t 9) ~-Wall (R-19) -Ceiling (R-30) -Baffles ~ -Fill Exposed Cavities ~ VAPOR BARRIER -Paint -Crawl Space - 6 Mil Poly DRYWALL NAILING -Walls -Ceiling FINAL Final-House Number Issued: 1!30/98 Lot: Block: ~G t-r-k~ BLD97-00184 Call 48 hours before you dig for utility fine locates 1-800-424-5555 • Page 2 of 3 City of Port Townsend Port ownsend tWA 96368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1205 29TH ST Parcel No: 957901201 Project: SPECIAL CONDITIONS /RESTRICTIONS Issued: 1130198 Lot: k: j~~i,{i-(~ BLD97-0 184 TEMPORARY EROSION & SEDIMENT CONTROL (TSEC): Permitee/contractor to install temp. erosion control measures as required during construction. Measures to include but not limited to installation of silt fencing and graveled construction entrance. Public right-of-way shall be kept clean. Tracking of mud and debris from the site not allowed. Failure to comply will result in all work being stopped. DEMOLITION: All construction debris to be deposited in approved areas in accordance with local, state and federal laws. PLUMBING: Pressure Reducing Valve required if water pressure greater than 8D psi. GENERAL CONDITIONS • 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. CaII for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 C~ i