HomeMy WebLinkAboutBLD97-179City of Port Townsend
Building and Community Development
540 Water Street
PoR Townsend, WA 98368
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2256 RAINIER ST
Parcel No: 955900012
Project:
-CONTRACTOR/OWNE
JAIME KOZELISKY
Issued: 10/29/97
Lot: 12 Block:
PERMIT # BLD97-00179
WNE
HAMILTON HEIGHTS, LLC.
1140 140TH AVE NE #D
BELLEVUE, WA 98005
rrw~w, v~.av~~u
New single family residential: Install 1414 sq. ft. manufactured home with 240 sq. ft. garage and 126 sq. ft. porch
City Contact: JLZ Construction TypelOcc Use/Occ Load
Type o(work: NEW Construction Occupancy
Type of use: SF Type 1: Group t: load 1:
Census Category: 101 Type 2: Group 2: Load 2:
Estimated Value: $fi0,000.00
Type 3; Group 3: Load 3:
' Zoning:
SI Code: PUD
Type 4;
Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~~ -Stem Wall
TEMP EROSION & SDM'T CON -Forms
Insp-See Special Conditions #~ -Reinforcement
FOOTINGS -Anchor Bolts
Insp-See Special Conditions ~~ -Vents
-Setbacks -Crawl Access
-Footings -Alt BWP HOldown Hdwr
-Forms SLAB
-Reinforcement Insp-See Special Conditions
-Porch/Deck Bay Piers -Setbacks
-LIFER; -Forms
FOUNDATION ~,~, }, _ ~ ~. , ; ~ ~; i ~^ ? J -Slab
;p-See Special Conditions # -Reinforcement
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
City of Port Townsend 640 Water Street -
Port Townsend, WA 98388
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2256 RAINIER ST Issued: 10!29197
Parcet No: 95590D012 Lot: 12 Block:
Project: PERMIT # BLD97-00179
Inspection Date Inspector Inspection Date Inspector
-Steel Support Piers Z ~ ~ -Roof
FLOOR FRAMING -Attic Venting
Insp-See Special Conditions ~- -Weather Resistive Barrier
-Girders VAPOR BARRIER
-Positive Connection -Crawl Space - 6 Mil Poly
-Treated Wood to Concrete DRYWALL NAILING
PLUMBING -Walls
Insp-See Special Conditions # -Ceiling
Insp-See Special Conditions ~. -Garage/House Occ. Separation
Insp-See Special Conditions ~ DRAINAGE
Insp-See Special Conditions ~~p Insp-See Special Conditions ~-
Insp-See Special Conditions ~~ -Per Master Plan
Insp-See Special Conditions .ff~~ FINAL
-Water Supply Insp-See Special Conditions ,~f~g
-Gas Supply ~~ A L/C~H~ Insp-See Special Conditions.pE~
-Hose Bibs (bckflw pro. regd) Final-House Number
-Pipe Insulation Final-Plumbing
MECHANICAL Final-Mechanical/Heating
Insp-See Special Conditions ,# Final-Smoke Detectors
Insp-See Special Conditions ~~ Final-Public Works Sign-Off
-Duct Insulation Final-LPG (Fire Dept. y~gyp~j~gg
-Whole House Fan Final -Electrical (L&I)
FRAMING ' Final -Building
Insp-See Special Conditions # Jr
Insp-See Special Conditions ~~
-Walls
-Alternate Braced Wall Panel
Call 48 hours before you dig for utility line locates
1-800-424-5555
I
Page 2 of 4
City of Port Townsend 640 Water Street
Port Townsentl, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST 8E ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2256 RAINIER ST Issued: 1o/z9/s7
Parcel No: 955900012 Lot: 12 Block:
Protect: PERMIT # BLD97-00179
SPECIAL CONDITIONS /RESTRICTIONS
1 . HOURS: Outdoor construction activities on the site shall be limited to the hours of 7:30 a.m. to
6:00 p.m. Monday through Friday, and prohibited on weekends and national holidays.
2. TESC: Per Hamiltion Heights Mater Plan and Department of Ecology Best Management
Practices.
3. FOOTINGS: Applies to garage/porch only.
4. FOUNDATION: Applies to garage only.
5. SALB: Proposed 4" slab for garage okay; reinforced concrete slab for home requires minimum
4 1/4" slab.
6. FLOOR FRAMING: Applies to site-built porch only.
7. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
PLUMBING: Main shut-off valve to be installed in water supply piping prior to connection to
home. Valve shall be full-flow type (gate or ball valve); minimum 3/4" diameter, same as
supply pipe.
9. PLUMBING: Freeze protection (insulation) required for water supply pipes outside and in crawl
space.
10. PLUMBNG: Pressure test required; water pressure at 100 psi for 15 minutes.
11 . PLUMBING: Water heater pressure relief valve drain shall extend outside of skirting, w/elbow
down and terminate between 6" and 24" above ground.
12. PLUMBING: Horizontal runs in drainage system shall be sloped minimum 1/4" per foot.
13. MECHANICAL: Whole house exhaust fan timer shall be set to operate for 2 4-hour periods per
day unless central exhaust fan is set to run continuously.
14. MECHANICAL: Dryer exhaust shall be vented to the outside. Extension into crawl space
requires venting through skirting with no dips; follow dryer manufacture>'s instructions.
Moisture exhaust ducts shall not exceed total combined vertical and horizontal length of 14
feet with 2 90-degree elbows.
15. FRAMING: All elements of alternate braced wall panel require inspection prior to cover.
16. FRAMING: Alteration insignia for garage/porch shall be posted on home at inspection time.
17. DRAINAGE: Alt water drains piped to outside shalt drain away from home; ground to slope
away from home for minimum 5 feet @ 1/2 "per foot.
18. FINAL; Pier supports and anchors per manufactured home installation manual require
inspection prior to skirting.
19. FINALISKIRTING: No holes or gaps greater than 1/4" allowed in skirting. Crawl space
ventilation per manufacturer's specs or 1/i50 (14 req'd.), located on at least two opposing sides
to provide for cross ventilation. Crawl space access required: one (1) per section or as
required by manufacturer, minimum 18" x 24".
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend P ~ ownsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD °-~
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2256 RAINIER ST Issued: 10/29/97
Parcel No: 955900072 Lot: 12 Block:
Project: PERlUIIT # BLD97-00179
GENERAL CONDITIONS
1. A separate electrical permit is required far any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
Waterman 1. Ke1z Building
181 Qulnry Streel. Suite 301
Port Tow~uend. WA 98166
Phone: 3603793206 Fss 3603796973
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD97-00179R-1
Job Address: 2256 Rainier Street
Total Occupant Load:
Owner: Hamilton Heights LLC
Issued: 2/19//99 Parcel Number: 955900012
Zoning: RR=II Type: VV=N Occupancy: R-3/U-1
Nature of Work: Engineered detail for 16"BWP
Contractor: Same as Owner
GENERAL CONDITIONS APPLY:
SEPARATE PERMITS REOUIItED:
• Framing
FINAL
Final -Building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept
• GENERAL CONDITIONS
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Pagel of 2
u
Waterman & Kati Huild[ng
181 Quiney Street, Suile 301
PoR Towoeend. WA 98368
Phone: 360-3793208 Paz360J79-6921
GENERAL CONDITIONS
free of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
.construction is complete. Applicant is responsible far protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required aker inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3.
A minimum of twenty-four hours notice is required Public Works approval must be received prior to
scheduling the Buildin¢ Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
• 8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Paget of 2