Loading...
HomeMy WebLinkAboutBLD97-176City of Port Townsend 540 Water Street Port Townsend, WA 98568 Building and Community Development • BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 3853`294 For Inspection 3;'f- ;.- Site Address: 1428 MONROE ST Issued: 1117197 Parcel No: 984601204 Project: Lot: Block: PERMIT # BLD97-00176 WNE BRUCE FREELAND 1428 MONROE STREET 379-6992 -CONTRACTOR/OWNE TOWNSEND BUILDERS, INC. 210 TAYLOR STREET PORT TOWNSEND, WA 98368 Residential: Reinforce existing foundation. City Contact: JLZ Construction 7ype/Occ UselOCC Load Type of work: REP Construction Occupancy Type of use: SF Type 1: SN Group t: R-3 load 1: Census Category: 575 Type? Group 2: Load 2: Estimated Value: $33,000.00 Type 3: Group 3: load 3: Zoning: R-II SI Code: Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector FOUNDATION Steel Angles Insp-See Special Conditions ~~ Steel Plates Insp-See Special Conditions #~„ Clips lnsp-See Special Conditions #3 Nailing Insp-See Special Conditions ~-cf Final-House Number Insp-See Special Conditions #~ Final-Building -Stem Wall -Reinforcement -Anchor Bolts ~ ~jd.4L -Lat. Restraint Holdown Hdwr FINAL Insp-See Special Conditions #'(~ ~-See Special Conditions # 7 Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 City of Port Townsend PartvTownsend[WA 98388 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1428 MONROE ST Issued: 11/7/97 Parcel No: 984801204 Lot: Block: Protect: PERMIT # BLD97-00176 SPECIAL CONDITIONS /RESTRICTIONS 1 . FOUNDATION: 5 1/2 sack concrete speed. 2. FOUNDATION: See engineered plans for holdown locations: STHDRJI4 speed with 2 #4 resteel w/ 18" legs ~ each side of holdown. 3. FOUNDATION: #4 x 8" resteel ~ 30" o.c. top & bottom of fdn. walls "A"; epoxy grout into existing fdn. wall - 4. FOUNDATION: #4 vertical bars @ 15" o.c. 8 #4 horizontal bars @ 12" o.c. for both "A" & "B" foundation walls. ' 5. FOUNDATION: #4 x 18" resteel @ 30" o.c. with minimum 3" embedment, epoxy grout into existing slab. 6. FINAL: Foundation Wall Section "A": 3" x 3" x 3116" x 8' steel angles required w! 10d x 1 1/2" nails @ 4" o.c.. Minimum length of steel angles should be 8' with 3 sections per 30' wall length. Also, 3/16" x 12" x 8' plate required with 10d nails staggered ~ 3" o.c. & 1/2" x 2 1/2" welded stud (bolt) ~ 36" o.c. 7. FINAL: Foundation Wall "B": Simpson A23 clips required ~ 16" o.c. for joist blocking/subfloor connection. 5/8" anchor bolts speed ~ 4' o.c. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call far at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 ar 2