HomeMy WebLinkAboutBLD97-152City of Port Townsend Port otwnsendtWA 98368
Building and Community Development
• BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1428 MONROE ST
Parcel No: 984601204
Project:
-CONTRACTOR/OWNE
TOWNSEND BUILDERS
210 TAYLOR STREET
PORT TOWNSEND, WA 98368
Issued: 10117/97
Lot: Block:
PERMIT # BLD97-00152
WNE
BRUCE FREELAND
1428 MONROE
PORT TOWNSEND, WA 98368
-PftOJtG I UtSI:FCIr I Ivl~
Residential: Interior remodel and repair of roof, chimney, windows, doors & first floor framing as needed due to rot.
City Contact: JLZ
Type of work: REP
Type of use: SF
Census Category: 434
Estimated Value: $17,500.00
Zoning: R-II
SI Code:
Construction 7ypelOcc Use/Occ Load
Construction Occupancy
Type 1: 5N Group 1: R-3 Load t:
Type 2: Group 2: load 2:
Type 3:
Type 4:
Group 3: Load 3:
Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions #~ MISCELLANEOUS
FLOOR FRAMING Mud Sill Replacement
Insp-See Special Conditions ~a Dry Rot Stud Replacement
-Joists FINAL
FRAMING Insp-See Special Conditions ~3
-Roof Final-House Number
-Air Seaf Final-Smoke Det. Througout
-Door U Value O Final -Building
CHIMNEYS ~.~ ~ ~ ~~~
-Chimney Reinforcement
-Chimney Straps
INSULATION
I Exposed Cavities
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page t of 2
City of Port Townsend Part ownsend[WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1428 MONROE ST Issued: 70/17/97
Parcel No: 984601204 Lot: Block:
Pro;e°t: PERMIT # BLD97-00152
SPECIAL CONDITIONS /RESTRICTIONS
1 . Work per scope of permit only; separate permit required for additional work. Demolition work
requires debris to be disposed of in accordance with state and local ordinances and
regulations. Separate electrical permit required for electrical work.
2. FLOOR FRAMING: First floorjoists may require replacement due to age deterioration and rot.
3. FINAL: Smoke detectors (SD) required throughout house per'94 UBC: SD's in each bedroom
and in hallways/areas outside bedrooms with minimum one detector on each floor. Inspection
required.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555