Loading...
HomeMy WebLinkAboutBLD97-151City of Port Townsend Po Townsend`WA 98168 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 821 JEFFERSON STREET Issued: 10/14/97 Parcel No: 989710501 Lot: 2,4 Block: 56 Protect: PERMIT # BLD97-00151 -CONTRACTOR/OWNE TOWNSEND BUILDERS, INC. 210 TAYLOR STREET PORT TOWNSEND, WA 98368 WNER- D'AMICO PENEE MARIE 521 TAYLOR ST PORT TOWNSEND, WA 983685828 TRVJGI.I VCJlirt~f- i wig Foundation Only(1,080 sq. ft); connect to city sewer; 3/4" water meter (future permit). City Contact: JS Construction Type/Oec UselOCC Load Type of work MOV Construdlon Occupancy Type of use: SF Type 1: SN Group 7: R-3 load 1: Census Category: 540 Type 2: Group 2: Load 2: Estimated Value: $33,000.00 Type 3: Group 3: Load 3: Zoning: R-II Type 4: Group 4: Load 4: 51 Code: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector Insp-See Special Conditions ~ -Reinforcement (~ Insp-See Special Conditions ~~, ~ ~ o Q~ ~ -Walls TEMP EROSION & SDM'T CON -LIFER Insp-See Special Conditions 3 FINAL FOOTINGS . , n .~ ~-': _~ 1- Insp-See Special Conditions Insp-See Special Conditions ~~ -Setbacks -Reinforcement SLAB Insp-See Special Conditions (~ sp-See Special Conditions #' .onolithic Slab/Fdn Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 7 of 2 City of Port Townsend Port ownsendtWA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUS7 BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 821 JEFFERSON STREET Issued: 10/14/97 Parcel No: 989710501 Lot: 2,4 Block: 56 Protect: PERMIT # BLD97-00151 SPECIAL CONDITIONS /RESTRICTIONS 1 . FOUNDATION ONLY Permit: Subsequent structure must be compatible with this foundation design. 2. See page 10 of final geo-tech report dated 10/13/97 for construction monitoring by geo-technical engineer of geo-technical aspects of project. 3. TEMPORARY EROSION AND SEDIMENT CONTROL (TESC): Approved engineered TESC measures which can be installed prior to foundation work (e.g. along the side of the site and graveled construction entrance) must be installed and inspected by City Engineering office, 385-2413, prior to any foundation work. INSPECTION REQUIRED. Subsequent silt fencing at rear of building/on bluff to be installed immediately after grading/foundation work. INSPECTION REQUIRED. Engineered stormwater management plan to be submitted with subsequent permit for remodel of structure. 4. AUGERCAST PILING INSPECTION: Geotechnical engineer to be present during placement. Copy report to Building Department. 5. FOOTINGS & CASSIONS: Special Inspections per UBC Section 1701 required for all concrete work including cassions. Special Inspection inspectors and agencies must be listed in WABO Certification Register or be approved by the Building Department PRIOR to any Special Inspections. Owner and/or Owners Agent shall review and oversee correction of any and all deficiencies noted by required Special Inspections. Copy to Building Department all Special Inspection Reports. 6. SLAB: See approved engineered plans for details. Note: some A.B.'s @ 12" O.C. 7. WALLS: See approved engineered plans for details. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 ~. Page 2 of 2 Waterman Bc 1(atx Building City of Port Townsend 181 Quincy Street, Suite 301 Pnrt Townund, WA 98368 (360) 379-3208 Fai: 379-6921 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 821 JEFFERSON STREET Parcel No: 989710501 Project: CHURCH RELOCA -CONTRACTORIOWNE TOWNSEND BUILDERS, INC. 210 TAYLOR STREET PORT TOWNSEND, WA 98368 Issued: 10!19/98 _.__._ ~~ BLD97-151 R1 D'AMICO PENEE MARIE 521 TAYLOR ST PORT TOWNSEND, WA 983685828 -PROJECT DESCRIPTIO Rev No. 1--Complete work to set building on fdn: Frame & sheath F-1 walls; Erect steel girder & post system (includes ext. deck); Install holdowns (F-1 to concrete & F-2 framing to concrete wall or steel. City Contact: RNS Construction TypelOcc UselOcc Load Type of work: MOV Construction Occupancy Type of use: SF Type 1: SN Group 1: R-3 Load 1: Census Category: 540 Type 2: Group 2: Load 2: Estimated Value: 521,000.00 Type 3: Group 3: Load 3: Zoning: R-II Type 4: Group 4: Load 4: SI Code: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector Insp-See Special Conditions Insp-See Special Conditions FRAMING Final-House Number ~~ "~E~T P~+PRo~' R13o1~E ~~ hiol~l~- ~ ~sPeZTrorl l TI: l15 Insp-See Special Conditions ~ 2 Insp-See Special Conditions ~ Insp-See Special Conditions Insp-See Special Conditions ~IAL __ ~ _ Call 48~hou~s before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Waterman & Kett Building City of Port Townsend Port Tuawnuad, WAu,98368t Building and Community Development t~~379-3208 Fsz: 379-6923 BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME .Call 385-2294 For Inspection Site Address: 821 JEFFERSON STREET Issued: 10/19/98 Parcel No: 989710501 Lot: Project: CHURCH RELOCA ~(~ BLD97-151 R1 SPECIAL CONDITIONS /RESTRICTIONS 1 . FOUNDATION PERMIT ONLY: Resulting structure must be compatible with foundation design and must comply with all applicable codes. 2. SPECIAL INSPECTION REQUIREMENT: Required Special Inspection Reports to be copied to Building Department in a timely manner. Permit Holder or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by required special inspections, 3. FRAMING: See approved engineered plan's for details. All engineered elements require inspection prior to cover. 4. FRAMING: Special Inspection per UBC Sec 1701 required for Structural Steel and Welding. Special Inspector to be Washington licensed engineer or ICBO certified inspector ICBO certified inspector to either be listed in curcent edition of WABO "Agency and Inspector Register" or present ICBO credentials to Building Department PRIOR to pertorrning inspections 5. FRAMING: Special Inspection per UBC Sec 1701 required for High Strength Bolting. Special Inspector to be Washington licensed engineer or ICBO certified inspector. ICBO certified inspector to either be listed in curcent edition of WABO "Agency and Inspector Register" or present ICBO credentials to Building Department PRIOR to performing inspections. 6. FINAL: Structure to be placed on foundation per engineered plans. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Page 2 of 2