BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS. MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4095 JACKMAN ST
Parcel No: 933302501
Project:
Inspection Date Inspector
DRYWALL NAILING f `7 ;~%(1
FA,~" ~;
Insp-See Special Conditions ~ ~
-Walls
-Ceiling
-Interior Braced Wall Panels
-Garage/House Occ. Separation
FINAL
Insp-See Special Conditions
Final-House Number
Final-Plumbing ~
al-Mecha nica I/Heating
Final-Insulation Certificate
Final-Vapor Barrier Cert.
Final-Smoke Detectors
Final-Public Works Sign-Off
Final-LPG (Fire Dept.)
Final -Building ~ ~~~ ~~
Issued: 11 /10/97
Lot:
PERMIT #
Block:
BLD97-00150
SPECIAL CONDITIONS /RESTRICTIONS
1 . Outdoor constructicn activities shall be limited to the hours of 8:00 a.m. to 6:00 p.m. and
prohibited on weekends and national holidays.
2. TESC: Temporary erosion control measures shall be implemented on site as-needed per
engineered plan for Lynnesfield.
3. FOUNDATION: Holdowns required at garage wall comer per ABWP detail.
4. SLAB: 4" anchor bolts required for IBWP on garage slab; see Sheets 1 8 3 of 3.
5. FLOOR FRAMING: IBWP require double floorjoists under if parallel, blocking between joists
if perpendicular.
6. PLUMBING: Pressure reducing valve required if water pressure exceeds 80 psi.
i
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend 540 Water Street v
Port Townsend, WA 98366
Building and Community Development ~
BUILDER'S PERMIT AND INSPECTION RECORD a
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4095 JACKMAN ST Issued: 11/10/97
Parcel No: 933302501 Lot: Block:
Protect: PERMIT # BLD97-00150
SPECIAL CONDITIONS /RESTRICTIONS
7. FRAMING: All elements of braced wall panels, ie. interior, exterior & alternate, require
inspection prior to cover.
8. DRYWALUNAILING: IBWP shall be spaced not greater than 25 feet o.c.; IBWP located along
walk-in closet wall and master bedroom wall require t3' panels both sides due to greater-than-4'
offset between end panels located at closet & pantry (see Sheet 1!3).
9. FINAL: Check with ColettelPW Engineering on infrastruction bond condition: Infrastructure
shall be completed prior to final of fourth SF dwelling.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
\J
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
City of Port Townsend 549 Water Street
Port Townsend, WA 96368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 4095 JACKMAN ST
Parcel No: 933302501
Project:
-CONTRACTOR/OWNE
CAMPBELL CONSTRUCTION
120 CURTIS STREET
PORT HADLOCK, WA
New single family dwelling (1620) with attached garage/shop.
Issued: 11/10/97
Lot: Block:
PERMIT # BLD97-00150
WNER-
CHARLES HOUGH
5005 LANDES
PORT TOWNSEND, WA 98368
City Contact: JLZ Construction TypelOcc UselOcc Load
Type of work: NEW Construction Occupancy
Type of use: SF Type t: 5N Group 1: R-3 Load 1: 5
Census Category: 101 Type 2: Group 2: U-1 load 2: 4
Estimated Value: $142,183.20
Type 3:
Group 3: Load 3:
Zoning: R-II
Type 4: Group 4: Load 4:
SI Code:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions J -Stem Wall
TEMP EROSION & SDMT CON -Forms
Insp-See Special Conditions ~a -Reinforcement
FOOTINGS I ~ fL ~~ -Anchor Bolts
-Setbacks -Vents
-Footings -Crawl Access
-Forms -Beam Pockets
-Reinforcement -Alt BWP Holdown Hdwr
-Interior Footing SLAB
-Porch Bay Piers Insp-See Special Conditions
-LIFER IZ L ~~ -Setbacks
FOUNDATION -Anchor Bolts
p-See Special Conditions ~,~ FLOOR FRAMING I ~ ~,~ ~ ~°(7~
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
City of Port Townsend Port o`;~ge dtWA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION 71ME
Call 385-2294 For Inspection
Site Address: 4095 JACKMAN ST Issued: 11/10/97
Parcel No: 933302501 Lot: Block:
Protect: PERMIT # BLD97-00150
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions ~)f - -Source Specific Fan
-Girders -Environmental Air Exhaust
-Joists -Efficiency
-Blocking -18" A.F.F.
-Shield Under Posts FRAMING
-Int. Braced Wall Supports Insp-See Special Conditions ~
-Positive Connection -Walls.
-Girder to Concrete -Alternate Braced Wall Panel
-Beam Pockets -Ceiling
-Treated Wood to Concrete -Roof
-Anchor Bolts & Washers -Attic Venting
-FDN Vents tZ~Z~ 7 -Windows: Egress
PLUMBING 1 ~~ ~ ~ -Window U Value
Insp-See Special Conditions ~(P -Window Safety Glazing
-Rough-In (D-V-T & Cln Outs) -Air Seal
-Water Supply -Fresh Air Intake (Window)
-Gas Supply -Door U Value
-Hose Bibs (bckflw pro. regd) 2, f~j 9 -Fire Blocking
-Pipe Insulation -Weather Resistive Barrier
-Water Heater INSULATION
-18" A.F.F. -Floor (R-19)
-Seismic Restraint -Wall (R-19) 1 ~ c~~
MECHANICAL -Ceiling (R-30)
-Furnace -Baffles
-Heat Ducts VAPOR BARRIER
-Duct Insulation `~ cl ~ -Paint
-Whole House Fan -Crawl Space - 6 Mil Poly
Call 48 hours before you dig for utility line locates
1-800-424-5555
I~
Page 2 of 4
City of Port Townsend ~~ ~~''~, ~1t1~=~ ~
I P G Certificate Of Inspection
Mechanical Permit No.:
Building Permit No.: ~~ 'O~
Installatton Type: New ^ Container Change Only
Installation Data:
• Historical District Determination: .%~/~
• U.B.C. Use Classificatio.,n~ - 3
• Elements: f~ontainer(s) ~ Piping Appliance(s)
• ContainerSize/Type: .~oD ~ /~s~e (/G~
• Container Serial No.: O/2¢2 ~ 75 T d) ~ ' Z
• Container Mfr. Date: ! 99 ~- j
• Other tank(s) Type, Size, SB: ti0//E tP ~
• Test Pressure,Type: ~Ofs~.~//~ ~~..~
• Appliance Mfr.(s)/Model/SN: Pbt P~
B.ey4.+/7' F~ie//ACF: ~u n,.t/0 36 ~ 8U D,eR~ PE (uG~
• f~,¢.90FOk'D syH~7z= 7YU/'r •' S!i i a 3 itlOal ~ - - --- -• -
Appliance Location(s): GLJ?AGE
Listing{s):.4GA 'A-Gf}
Miscellaneous:
Inspection Elements:
• Container(s)
• Ptping
• Regulator(s)
• Apurtenances
• Setbacks
• Appliance(s)
• Other
JZl Approved
^ Conditional Approval:
Not approved:
p~ ' z_2 98
Inspected t3y: i'~~-~ ~/n'L-~ Date: ~ /~ /.~~'-
Port Townsend Fue Deparanent -LPG Inspection Form - 05/12/98