HomeMy WebLinkAboutBLD97-148City of Port Townsend
Building and Community Development
540 Water Street
Port Townsend. WA 98368
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2526 CREST AVE
Parcel No: 955800101
Project:
HAMILTON HEIGHTS, LLC.
1140 140TH AVE NE #D
BELLEVUE, WA 98005
Issued: 1011/97
Lot: Block:
PERMIT # BLD97-00148
WNER--'
HAMILTON HEIGHTS, LLC.
1140 140TH AVE NE #D
BELLEVUE, WA 98005
Residential -New manufactured home w/ attached garage
City Contact: JLZ Construction Type/Occ UselCCC Load
Type of work: NEW Construction Occupancy
Type of use: SF Type 1: SN Group 1: R-3 Load 1: 4
Census Category: 712 Type 2: Group 2: U-1 Load 2: 1
Estimated Value: $60,000.00 Type 3: Group 3: Load 3:
Zoning: PUD
Type 4:
Group 4: Load 4:
SI Code:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
RFCJt1IRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions .~E~ -Forms
TEMP EROSION 8 SDMT CON -Reinforcement
Insp-See Spectral Conditions .tea -Anchor Bolts
FOOTINGS -Vents
Insp-See Special Conditions # 3 ~~ '"- ~ ~;~; -;' -Crawl Access
-Setbacks ~~ -Alt BWP Holdown Hdwr
-Footings ~ SLAB ti'
-Forms Insp-See Special Conditions #~/'
-Reinforcement / -Setbacks ~
-Porch Bay Piers -Forms ~ ~
FOUNDATION ~ ~ -Slab ~
sp-See Special Conditions # -Reinforcement ~
em Wall -Steel Piers
Call 4$ hours before you dig for utility line locates
1-800-424-5555
Page t of 4
City of Port Townsend Port oxnsend `WA 9668
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2526 CREST AVE Issued: 10H/97
Parcel No: 955800101 Lot: Block:
Protect: PERMIT # BLD97-00148
Inspection Date Inspector Inspection Date Inspector
PLUMBING VAPOR BARRIER
Insp-See Special Conditions ~~ -Crawl Space - 6 Mil Poly
Insp-See Special Conditions ~ DRYWALL NAILING
Insp-See Special Conditions ~ ~ -Walls
Insp-See Special Conditions ~ 9 -Ceiling
Insp-See Special Conditions ,~~p -Garage/House Occ. Separation
Insp-See Special Conditions ~ ~/ DRAINAGE
-Water Supply Insp-See Special Conditions .#~6
-Gas Supply -Per Master Plan
-Hose Bibs (bckflw pro. regd) FINAL
-Pipe Insulation Insp-See Special Conditions ~f~
-Water Heater Insp-See Special Conditions #~
-Seismic Restraint Final-House Number
MECHANICAL Final-Plumbing
Insp-See Special Conditions ~~Z Final-MechanicaUHeating
lnsp-See Special Conditions ~f /3 Final-Smoke Detectors
-Duct Insulation ~~ Qj Final-Public Works Sign-Off
-Whole House Fan Final-LPG (Fire Dept.)
FRAMING Final -Electrical (L81)
Insp-See Special Conditicns ~ Final -Building F
Insp-See Special Conditions ~~S
-Walls
-Alternate Braced Wall Panel
-Roof
-Attic Venting
-Air Seal
-Weather Resistive Barrier
I
Call 48 hours before you dig for utility line locates
1-800-424-5555
. 1
Page 2 of 4
City of Port Townsend Port ownsendtWA 96368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2526 CREST AVE Issued: 1011197
Parcel No: 955800101
Project: PE~MiT # BLD97-00148
SPECIAL CONDITIONS /RESTRICTIONS
1 . HOURS: Outdoor construction activities on the site shall be limited to the hours of 7:30 a.m. to
6:00 p.m. Monday through Friday, and prohibited on weekends and national holidays.
2. TESC: Per Hamilton Heights Master Plan and Department of Ecology Best Management
Practices.
3. FOOTINGS: Applies to garage/porch only.
4. FOUNDATION: Applies to garage only.
5. SLAB: 4" slab for garage okay; reinforced concrete slab for home requires minimum 4 1/4"
slab.
6. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
~7. PLUMBING: Main shut-off valve to be installed in water supply piping prior to connection to
home. Valve shall be full-flow type (gate or ball valve); minimum 3/4"diameter, same as
supply pipe.
8. PLUMBING: Freeze protection (insulation) required forwater supply pipes outside and in crawl
space. ,$b
9. PLUMBING: Pressure test required; water pressure at-~psi for 15 minutes.
10. PLUMBING: Water heater pressure relief valve drain shall extend outside of skirting, w/ elbow
down and terminate between 6" and 24" above ground.
11 . PLUMBING: Horizontal runs in drainage system shall be sloped minimum 114" per foot.
12. MECHANICAL: Whole house exhaust fan timer shall be set to operate for 2 4-hour periods per
day unless central exhaust fan is set to run continuously.
13. MECHANICAL: Dryer exhaust shall be vented to outside. Extension into crawl space requires
venting through skirting with no dips; follow dryer manufacturers instructicns. Moisture
exhaust ducts shall not exceed total combined vertical and horizontal length of 14 feet with 2
90-degree elbows.
14. FRAMING: Factory-built parch per manufacturers specs.
15. FRAMING: Alteration insignia for garage shall be posted on home at inspection time.
16. DRAINAGE: All water drains piped to outside shall drain away from home; ground to slope
away from home for minimum 5 feet @ 1/2" per foot.
17. FINAL: Pier supports and anchors per manufacturers installation instructions require
inspection prior to skirting.
18. FINAUSKIRTING: No holes or gaps greater than 1/4" allowed in skirting. Crawl space
ventilation per manufacturer's specs or 11150, located on at least two apposing side to provide
for cross ventilation. Crawl space access required: one (1) per section or as required by
manufacturer, minimum 18" x 24".
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend Port ownse d`WA 88768
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2526 CREST AVE Issued: 10/1197
Parcel No: 955800101 t- Block:
Pro;ect: PE MIT # BLD97-00148
GENERAL CONDITIONS ~
1. A separate electrical permit is required for any electrical work.
2. Reinspedions are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
L_J
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 0( 4