HomeMy WebLinkAboutBLD97-139City of Port Townsend Po TownsendtWA 98388
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 336 43RD ST
Parcel No: 933302013
Project:
Issued: 9119197
Lot:
fT #
Block:
BLD97-00139
DENNIS COOPER I~ 2~6j -~~
336 43RD ST <_ ,;- --
PORT TOWNSEND, WA 98368
Residential -Construction of a new garage (640 sq ft)
CATHERINE, KANE
336 43RD ST
PORT TOWNSEND, WA 983683329
City Contact: Construcflon Type/Occ UsdOce Load
Type of vrork NEW Construc8on Occupancy
Type of use: SF Type f: SN Group 1: U-1 Load 1: 2
Census Category.
Type 2:
Group 2: Load 2:
Estimated Value: $t6,972.80
Type 3: Group 3: Load 3:
Zoning: R-II
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
GROUNDWORK PLUMBING -Walls
Insp-See Special Conditions #~ -Alternate Braced Wall Panel
gtp,g -Roof
Insp-See Special Conditions ~~ -Door(s)
-Setbacks FINAL
-Forms Insp-See Special Conditions #
-Monolithic Slab/Fdn Insp-See Special Conditions ~-~
-Reinforcement Final-House Number
-Anchor Bolts Final -Building
-Alt BWP Holdown Hdwr /'
~~i~r IYt~~PI'~u~ `~~
"
~
-LIFER ~,~ ~ f/
4 1~ ~
I
u-t
~ ~I~ ~0? ~ ~z (.f Ci.I~LY -
4MING
I~~~sp-See Special Conditions ~3
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
City of Port Townsend 540 Water Street
Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 336 43RD ST Issued: 9/19/97
Parcel No: 933302013 Lot: Block:
Protect: PERMIT # BLD97-00139
SPECIAL CONDITIONS /RESTRICTIONS
1 . GROUNDWORK PLUMBING: Rough out water closet and sink drain, waste and water supply
for future completion. Additional permit required.
2. SLAB: One corner of garage to have 13 lin. ft. of 6" stem wall, 18" high; inspection required.
3. FRAMING: All elements of Alt. Braced Wall Panel require inspection prior to cover.
4. FINAL: Recorded Restrictive Covenant required prior to final.
5. FINAL: Recorded Hold Harmless Agreement required prior to final.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active,
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
\J
~~