HomeMy WebLinkAboutBLD97-123City of Port Townsend Water Street
Port Townsend, WA 88368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 908 HASTINGS AVE
Parcel No: 957901406
Project:
-CONTRACTOR/OWNE
STAPH CONSTRUCTION
PO BOX 212
HADLOCK, WA 98339
Issued: 7129/97
Lot: Block:
PERMIT # BLD97-00123
WNE
FRANCIS THOMPSON
908 HASTINGS
PORT,TOWNSEND, WA 98368
Residential -Demo of old garage (520 sq ft) and construction of new (1152 sq ft).
City Contact: JLZ Construction Type/Occ UselOtt Load
Type of work NEW Construction Occupancy
Type of use: SF Type t: 5N Group 1: U-1 Load 7: 6
Census Category. 438 Type 2: Group 2: Load 2:
Estimated Value: $30,000.00
Type 3: Group 3: Load 3:
Zoning: R-II
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
FOOTINGS - c-I ,~~ (: Insp-See Special Conditions #/
-Setbacks -Walls
-Footings -Alternate Braced Wall Panel
-Forms -Ceiling
-Reinforcement -Roof
-LIFER ri r ~,~, ~ FINAL
FOUNDATION Final-House Number
-Stem Wall ~' Final -Building ~ ~ l ~ ~` '
-Forms ~
-Reinforcement
-Anchor Bolts
-Alt BWP Holdown Hdwr
iMING
Call 48 hours before you dig for utility line locates
1-800-424-5555
Paga 7 of 2
City of Port Townsend Water Street
Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 908 HASTINGS AVE Issued: 7129/97
Parcel No: 957901406 ~~~:~ ~~ ~ Block:
Project: BLD97-00123
SPECIAL CONDITIONS /RESTRICTIONS
1 . FRAMING: 16" centers required for 2 x 4 wall framing to accomodate T-1-11 siding. Interior
braced wall line in open floor plan not required due to combination of small size of building and
sheathing installed all walls and roof. Panel grade for siding must be Structural #1 to meet wall
bracing requirements.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2