HomeMy WebLinkAboutBLD97-122City of Port Townsend Building and Community Development 540 Water Street Part Townsend, WA 98368 BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4820 MAGNOLIA Parcel No: 951904001 Project: -CONTRACTOR/OWNE TERHUNE HOMES PO BOX 97 POULSBO, WA 98370 Issued: 11/10/97 Lot: Black: PERMIT # BLD97-00122 WNE THERESA CAIN 1035 12TH STREET PORT TOWNSEND, WA 98358 New single family dwelling (2165 sq ft), garage (459 sq ft), porch (204 sq ft). City Contact: JLZ Construction TypelOcc UselOcc Load Type of work NEW Construction Occupancy Type of use: SF Type 1: 5N Group 1: R-3 Load 1: 7 Census Category: 213 Type 2: Group 2: U-1 Load 2: 2 Estimated Value: $172,211.92 Type 3: Group 3: Load 3: Zoning: R-I .. SI Code: Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector Insp-See Special Conditions .~f~ -Stem Wall 2t ~(, `h ~Ay , TEMP EROSION & SDM'T CON -Forrns Insp-See Special Conditions #j -Reinforcement FOOTINGS ~ I~b C~ -Vents - -Setbacks -Crawl Access Ia GV -Footings -Lat. Restraint Holdown Hdwr -Forms SLAB -Reinforcement Insp-See Special Conditions ~~ -Interior Footing -Setbacks -Porch Bay Piers -Reinforcement -LIFER -lat. Restraint Holdown Hdwr FOUNDATION FLOOR FRAMING ~ r ~ i y.i ~?~ }See Special Conditions ,#'3 Insp-See Special Conditions #~' Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 City of Port Townsend 640 Water Street Port Townsend, WA 98368 A Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME a Call 385-2294 For Inspection Site Address: 4820 MAGNOLIA Issued: 11/10/97 Parcel No: 951904001 Lot: Block: Project: PERMIT ~ BLD97-00122 Inspection Date Inspector Inspection Date Inspector -Girders Insp-See Special Conditions ,~ .Joists Insp-See Special Conditions ~g -Blocking Insp-See Special Conditions #9 -Shield Under Posts Insp-See Special Conditions ~~0 -Int. Braced Wall Supports -Walls -Positive Connection -Engineered Shear Walls -Treated Wood to Concrete -Alternate Braced Wall Panel -Anchor Bolts & Washers -Blk'g for GWB IBW Panels -FDN Vents -Seismic Anchors PLUMBING .~ ~ -Ceiling Insp-See Special Conditions #'~ -Roof -Rough-In (D-V-T & Cln Outs) -Attic Venting -Water Supply -Windows: Egress -Hose Bibs (bckfhv pro. regd) -Window U Value ~ -Pipe Insulation -Window Safety Glazing -Water Heater -Air Seal Z ~ -18" A.F.F. -Fresh Air Intake Make-up Air -Seismic Restraint -Door U Value MECHANICAL 2 ~ -Fire Blocking -Heat Pump -Weather Resistive Barrier -Heat Ducts INSULATION -Duct Insulation -Floor (R-19) -Whole House Fan -Under WH (R-10) -Source Specific Fan -Wall (R-19) t/ -Environmental Air Exhaust -Ceiling (R-30) -Efficiency -Baffles ~ FRAMING 'L ~ VAPOR BARRIER Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 n City of Port Townsend Po TownserndeWA 98388 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4820 MAGNOLIA Parcel No: 951904001 Project: Issued: 11/10197 Lot: PERMIT # Inspection Date Inspector) Insp-See Special Conditions ~-~~ -Crawl Space - 6 Mil Poly DRYWALL NAILING ~ ~~ O~ 7 -Walls -Ceiling -Interior Braced Wall Panels -Garage/House Occ. Separation -Enclosed Space Under Stairs FINAL Final-House Number al-Plumbing final-Mechanical/Heating ~ Final-Insulation Certificate Final-Vapor Barrier Cert. Final-Smoke Detectors Final-Public Works Sign-Off Final -Building ~/' i Block: BLD97-00122 SPECIAL CONDITIONS 1 RESTRICTIONS 1 . Alternate Braced Wall Panels ~ garage end walls and all engineered details require inspection prior to cover. 2. TESC: Owner/contractor shall install erosion control measures as needed during construction. Measures may include but are not limited to graveled construction access, covering of exposed soils, silt fencing, sweeping impervious surfaces, etc. 3. FOUNDATION: See Sheet 2/7, front west wall of house, for holdown (STHDBRJ) locations and 30" steel angle at corner. 4. SLAB: See Sheet 2/7 for holdown (STHD10) locations and steel angles at garage wall corners. 5. FLOOR FRAMING: 5/6" anchor bolts required for SW1 per engineered plan; see Sheet 3/7 for shear wall locations. ~. PLUMBING: Pressure reducing valve required if water pressure exceeds 80 psi. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 n City of Port Townsend P T wnsendtWA 98366 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 4820 MAGNOLIA Issued: 11H0/97 Parcel No: 951904001 Lot: Block: Pro;ed: PERMIT # BLD97-00122 SPECIAL CONDITIONS /RESTRICTIONS 7. FRAMING: Blacking at panel edges required for all interior and exterior shear walls. 8. FRAMING: See Sheef 1/7 for SW1 nailing, etc. of west front waft of main floor. 9. FRAMING: See Sheet 4/7 for upper floor beam-to-top plate strapping. 10. FRAMING: 4 x 10 porch header speed ~ DF #1. 11 . VAPOR BARRIER: Required; no vapor barrier speed on plans. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4