HomeMy WebLinkAboutBLD97-083City of Port Townsend 540 Water Street Port Townsend, WA 99368 Building and Community Development i BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 675 ROOT Parcel No: 974100705 Project: Issued: 719197 Lot: Block: PERMIT # BLD97-00083 WNE JIM CARLSON 84 PENNY LANE PORT TOWNSEND, WA 98368 -CONTRACTOR/OWNE JIM CARLSON 84 PENNY LANE PORT TOWNSEND, WA 98368 Residential - Construct a home (1984 sq ft), with a garage (576 sq ft), decks (180 sq ft) and porch (48 sq ft) City Contact: JLZ Construction 7ypelOcc UselOcc Load Type of work: NEW Constntction Occupancy Type of use: SF Type 1: SN Group 1: R-3 Load 1: 7 Census Category: 101 Type 2: Group 2: U-1 Load 2: 3 Estimated Value: $159,815.52 Type 3: Group 3: Load 3: Zoning: R-11 SI Code: Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector FOOTINGS - ,- ,~' i -Reinforcement s ~ ~~ :_ Insp-See Special Conditions ~ -Anchor Bolts -Setbacks % -Vents -Footings ~~ -Crawl Access -Forms -Lat. Restraint Holdown Hdwr -Reinforcement FLOOR FRAMING rJ /r `j' -Interior Footing % Insp-See Special Conditions / -Porch/Deck Bay Piers -Girders -LIFER '~ " - ~ Joists FOUNDATION -Blocking Insp-See Special Conditions -Shield Under Posts r -Stem Wall ~ / -Positive Connection ~ rms ~ -Girder to Concrete - ~ / r Call 48 hours before you dig for utility line locates 1-800-424-5555 Page t of 3 City of Port Townsend 640 Water Street ~ Port Townsend, WA 98368 , r Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 675 ROOT Issued: 719/97 Parcel No: 974100705 ot:~ p ./~ Block: Project: PE~IVIIT tt BLD97-00083 Inspection Date Inspector Inspection Date Inspector -Treated Wood to Concrete rj /~ Q -Window Safety Glazing a~ -~ -Anchor Bolts & Washers -Air Seal -FDN Vents -Door U Value PLUMBING -~ ~ Fire Blocking a -Rough-In (D-V-T 8 Cln Outs) Bather Resistive Barrier -Water Supply INSULATION a Ct~ -Hose Bibs (bckflw pro, regd) -Floor (R-30) -Pipe Insulation -Wall (R-19) -Water Heater -Ceiling (R-38) -Seismic Restraint -Baffles MECHANICAL VAPOR BARRIER -Remote Manifolded Fresh Air -Paint -Duct Insulation -~ -Crawl Space - 6 Mil Poly -Whole House Fan ~ ~ o~b DRYWALL NAILING -Source Specific Fan -Walls -Environmental Air Exhaust -Ceiling FRAMING a -~ ~ -Garage/House Occ. Separation Insp-See Special Conditions -Enclosed Space Under Stairs -Walls FINAL -Braced Wall Panels Final-House Number -Lateral Restraint Panel Final-Plumbing -Seismic Anchors Final-Mechanical/Heating -Ceiling Final-Insulation Certificate -Roof Final-Vapor Barrier Cert. -Attic Venting Final-Smoke Detectors -Windows: Egress Final-Public Works Sign-Off -Window U Value Final -Building 1L Call 48 hours before you dig for utility line locates 1-800-424-5555 ~ ~ Page 2 of 3 ' City of Port Townsend 540 Water Street i Port Townsend, WA 98568 1 Building and Community Development ~, BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 675 ROOT Issued: 7/9/97 Parcel No: 974100705 Lot: Block: Project: ~ERMIT ~ BLD97-00083 SPECIAL CONDITIONS !RESTRICTIONS 1 . FOOTINGS: See engineering specs and page three of plans for engineered footing detail. 2. FOUNDATION: See engineering specs and plans for location and details for holdowns and anchor bolts. 3. FLOOR FRAMING: Doubled BCI floorjoists required at kitchen wall; see page 1 of plans. 4. FRAMING: See plans for engineered details regarding floor/wall/roof sheathing and nailing, blocking and roof ties. """Contractor shall verify UBC height measurement at less than 30 feet.""' GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. • 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 t CITY OF PORT TOWNSEND BUILDER'S PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number BLD97-83R-1 Issued 6130197 Treas. Job Address 675 Root Zoning R-2 Type V-N Occupancy R-31U-1 Nature of Work Residential-Fdn Onlv Use of Building(s) Single Familv Dwelling wlGarage Owner Jim Carlson Contractor Jim Carlson Const.. Inc. NOTE: THIS IS A FOUNDATION ONLY PERMIT. SUBSEQUENT STRUCTURE MUST BE COMPATIBLE WITH THIS FOUNDATION DESIGN. Approved/Date FOOTINGS _ d.K. ~~ ~, ~`-~ ~J Setbacks, Reinforcement, Interior Footings UFER ~~ ~C~L G, ~y ~ FOUNDATION WALLS ~~j ~ ~Q/GJ~ Stem Walls, Reinforcement, Anchor Bolts, Vents, Crawl Access ~ ~ In, , VV w ~ 7 ~ ~~O G GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are completed. 3. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of i