BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2510 CREST AVE
Parcel No: 955800101
Project:
-CONTRACTOR/OWNE
OWNER CONSTRUCTION SERVICES
PO BOX 40376
BELLEVUE, WA 97015376
Issued: 6113!97
Lot: Block:
PERMIT ~` BLD97-00082
WNE
HAMILTON HEIGHTS LLC
1140 140TH AVE NE #D
BELLEVUE, WA 98005
Residential -Place 1335 sq. ft. manufactured home on full slab with 120 sq. ft. factory-built porch.
City Contact: JLZ Construction TypelOce UselOee Load
Type of viork: NEW Construction occupancy
Type of use: SF Type t: SN Group 1: R3 load 7: 5
Census Category: 112 Type 2: Group 2: Load 2:
Estimated Value: 518,120,80
Type 3: Group 3: Load 3:
Zoning: PUD
- SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
TEMP EROSION & SDMT CON Insp•See Special Conditions
Insp-See Special Conditions -Water Supply
-Vents -Hose Bibs (bckflw pro. regd)
-Crawl Access -Pipe Insulation
SLAB . Z . '~ ~ -Water Heater
Insp-See Special Conditions -Seismic Restraint
-Setbacks MECHANICAL
-Forrns Insp-See Special Conditions
-Slab Insp-See Special Conditions
-Reinforcement -Duct Insulation ~ - cG.;
PLUMBING FRAMING
Insp-See Special Conditions Insp-See Special Conditions
sp-See Special Conditions -Air Seal
Call 48 hours before you dig for utility line locates
` " `•'- ` ' ' 1-800-424-5555
,"
Page 1 of 3
City of Port Townsend water Street ^
PoR Townund, WA 88388
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2510 CREST AVE
Parcel No: 955800101
Project:
Inspection Date Inspector
VAPOR BARRIER
-Crawl Space - 6 Mil Poly Q Q ''
DRAINAGE
Insp-See Special Conditions
-Per Master Plan
FINAL
Insp-See Special Conditions
Insp-See Special Conditions
Final-House Number
Final-Plumbing
Final-Mechanical/Heating
Final-Smoke Detectors
Final-Public Works Sign-Off
Final -Electrical (L&I)
Final -Building G)
SPECIAL CONDITIONS /RESTRICTIONS
Issued: 8113/97
Lot:
PERMIT #
Block:
BLD97-00082
1 . TESC: Per the Hamilton Heights Master Plan
2. SLAB: Reinforced concrete slab requires minimum 4 1/4" slab.
3. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
4. PLUMBING: Main shut-off valve to be installed in water supply piping prior to connection to
home. Valve shall be full-flow type (gate or ball valve); minimum 3/4"diameter, freeze
protection required.
5. PLUMBING: Horizontal runs in drainage system to be sloped minimum 1/4" per foot.
B . MECHANICAL: Whole house exhaust fan timer set to operate for 2 4-hour periods per day
unless central exhaust fan is set to run continuously.
7. MECHANICAL: Dryer exhaust vented to outside; through floor into crawlspace requires
venting through skirting with no dips.
8. FRAMING: Factory-built porch per manufacturer's specs.
Call 48 hours before you dig for utility line locates
1-800-424-5555
r1
LJ
Page 2 of 3
City of Port Townsend 540 Water Street
Port Townsend, WA 98568
Building and Community Development.
i BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2510 CREST AVE Issued: 6/13!97
Parcel No: 955800101 Lot: ~ Block:
Project: PERMIT 1`e' BLD97-00082
SPECIAL CONDITIONS 1 RESTRICTIONS
9. DRAINAGE: All water drains piped to outside shall drain away from home; ground to slope
away from home for minimum 5 feet ~ 1/2" per foot.
10. FINAUSKIRTING: No holes or gaps greater than 1/4" allowed in skirting. Crawl space
ventilation per manufacturer's specs or 11150 located on at least two opposing sides to provide
for cross ventilation. Crawl space access req'd, one (1) per section; minimum 18" x 24".
11 . FINAL: Supports and anchors per manufacturer's installation instructions; ridge beam column
supports to be located directly under columns.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
• 4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call far et least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555