HomeMy WebLinkAboutBLD97-070, ~ City of Port Townsend
Building and Community Development
540 Water Street
Port Townsend, WA 98368
BUILDER'S PERMIT AND INSPECTION RECORD
~`
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1205 GISE
Parcel No: 948307303
Project:
Issued: 6/19197
MIT ~ BLD97
STAPH CONSTRUCTION
PO BOX 212
HADLOCK, WA 98339
New single family dwelling (2620 sq ft)
MICHAEL J PEARCE
2333 SHERIDAN
~
. ~ City Contact:
~
Type of work: NEW
Type. of use: SF
.`C Census Category:
~ Estimated Value: $205,913.66
Zoning: R-II
SI Code:
.^
u/~ Cal! 48 hours before ou di for utili Ilne locates
R'A W G Gr42 ~jTt~! Y g tY
~ (L ' ~5 7/3~~9 ~ 1-800-424-5555
Construction TypelOCC tlse/OCC Load
Construction Occupancy
Type is SN Group 1: R-3 Load 1:
Type 2: Group 2: U-t Load 2:
Type 3: Group 3: Load 3:
Type 4: Group 4: Load 4:
9
3
SPECIAL CONDITIONS/RESTRICTIf~NS APPLY -SEE LAST PAGE
~'~~ i REQUIRED INSPECTIONS
coon Dat _... _Inspector Inspection Date I Inspector
PLUMBING ~ Zvi ~ ~ f Anchor Bolts 770 ~S
o'~i .
-Vents
-1 Or E-l0 u-IO 7 ~ s- P7 k~ La -Crawl Access
-Beam Pockets 02 t"~o5"f ~
Forms -Waterproofing
Reinforcement FLOOR FRAMING f~ ;: ~~.,. ~ I
nsp-See Special Conditions ~} i ~ ;
nterior Footing
-Porch/Deck Bay Piers Insp-See Special Conditions ,#Z
~-LIFER ( ~ ~ ~C~-- ~;C, -Girders
FOUNDATION ~M~ ~r
-Stem Wall ~ -~ -Joists
-Blocking
-I
-Forms -Int. Braced Wall Supports _~
:einforcement - f' -Positive Connection E
Page 1 of 3
City of Port Townsend POtTownsendeWA 98368 w
Building and Community Development `
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1205 GISE
Parcel No: 948307303
Issued: 6119!97
lock:
Project: I'(# BL D97-0007 0
Inspection
i Date Inspector Inspection ate Inspector
~
'-Treated Wood to Concrete
W Z3 S J
~'
-Window U Value
~
I-Anchor Bolts & Washers -Window Safety Glazing
-FDN Vents -~ ` c /~~ ~ -Air Seal
PLUMBING -Door U Value
-Rough-In (D-V-7 & Cln Outs) G -Rafter/Truss Pos. Conn. ~
~,-Water Supply ~~- -Fire Blockin
-Gas Supply - Bather esistive Barrier ~~ ~l ~~
'-Hose Bibs (bckflw pro. regd) -lab (R10) Cl ? /~ .T
-Pipe Insulation (~ i-6 „ (~ -Floor (R-19) ~ G
'-Pressure Reduction Valve -Below GD Wall (R-19)
',-Water Heater -Wall (R-19)
'MECHANICAL 4.. ~ -Ceiling (R-30)
-Furnace -Baffles
~-Exhaust VAPOR BARRIER ~ ~ ~' !~
j-Heat Ducts
~-Combustion Air -Paint
DRYWALL NAILING
4 ~ ~,.~'
-Remote Manifolded Fresh Air -Walls I
-Duct Insulation -Ceiling
-Source Specific Fan -Interior Braced Wall Panels
-Heat Source Equip. & Controls -Garage/House Occ. Separation
iFRAMING d . G e( 'b L -Enclosed Space Under Stairs
!Jnsp-See Special Conditions ~ 4j
-Walls ~ gjpA~ WAw p,4NkU` o ~
~ G FINAL
Insp-See Special Conditions ~ (; ~ 4
-Blk'g for GWB IBW Panels ~ t r ~ ~ ~ Final-House Number
-Roof ~ Final-Plumbing
-Attic Venting Final-Mechanical/Heating
~_-
~-Windows: Egress _
Final-Insulation Certificate
~ 6 ~-~
~
Call 48 hours before you dig for utility line locates
1-800-424-5555
~~
Page 2 of 3
City of Port Townsend Port ownsendtWA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1205 GISE
Parcel No: 948307303
Project:
Inspection Date Inspector;
Final-Vapor Barrier Cert. ~ a,' ~:
Final-Smoke Detectors
Final-Public Works Sign-Off
,Final-LPG (Fire Dept.)
.Final -Building
Issued: 6119197
L ~ Block:
~p21-~'tT LD97-00070
SPECIAL CONDITIONS /RESTRICTIONS
1 . FLOOR FRAMING: Inspect crawl space for framing prior to cover. Remaining floor system
may be inspected at Framing Inspection.
2. FLOOR FRAMING: Double joists, blocking, beam or wall required under interior braced wall
sections.
3. FRAMING: See note on approved plans for engineered requirements for house/garage
common wall. All engineered elements require inspection prior to cover.
4. FINAL: Letter from mechancial contractor stating certification for fresh air damper per
WSVIAO.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3