HomeMy WebLinkAboutBLD97-060City of Port Townsend PortyTownsend, WA 88768
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 600 CLIFF ST
Parcel No: 989800006
Project:
HERITAGE CONSTRUCTION
12014 20TH STREET SE
EVERETT, WA 98205
-PROJECT DESCRIPTIOrt
Commercial: 3200 S.F. Dental Clinic
Issued: 6/13/97
Lot: Block:
P~~~ ~T ~ BLD97-00060
-OWNE
EDWARD SAVIDGE
1304 SIMS WAY
PORT TOWNSEND, WA 98368
City Contact: JLZ Construction TypelOcc UselOcc Load
Type of work: NEW Construction Occupancy
Type of use: COM Type 1: SN Group 1: B Load 1: 24
Census Category. 324 Type 2: Group 2: Load 2:
Estimated Value: $299,962.00
Zoning:
PUO Type 3: Group 3: Load 3:
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
r
L
Inspection Date Inspector Inspection Date Inspec r
TEMP EROSION & SDMT CON -Vents
Insp-See Special Conditions ~~ -Crawl Access
FOOTINGS (~ 2 -Lat. Restraint Holdow dwr ~~ ~ i~ ~
-SetbacksN-? S-aa, e- ,,w-s FLOOR FRAMING
-Footings Insp-See Special Conditions ~3
-Reinforcement -Girders
-Interior Footing -Joists
-LIFER -Blocking
FOUNDATION -Positive Connection
Insp-See Special Conditions #-2,- -Treated Wood to Concrete
-Stem Wall -FDN Vents
inforcement PLUMBING Z j i ~~ i~ ;'~
.nchor Bolts Insp-See Special Conditions #9
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page t of 3
City of Port Townsend P n ownse atwasasss
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD ~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 600 CLIFF ST Issued: 6/13/97
Parcei No: 989800006 Lot: Block:
Project: PERMIT # BLD97-00060
Inspection Date Inspector Inspection Date Insp ctar
-Rough-In (D-V-T & Cin Outs) Insp-See Special Conditions ~ Z 4
-Water Supply 2 ~? i Insp•See Special Conditions #~
- as Supply ~~ VAPOR BARRIER 2 Z 1 Q
-Hose i s (bckflw pro. regd) Insp-See Special Conditio s ¢fB
-Barcier-Free Required DRYWALL NAILING j L c~
-Pipe Insulation -Fire Rated Walls
-Pressure Reduction Valve T-BAR GRID CEILING
-Water Heater PARKING
MECHANICAL Z LANDSCAPING
-Furnace LIGHTING
-Heat Ducts MOTORS
-Remote Manifolded Fresh Air FINAL
-Duct Insulation Insp-See Special Conditions ~~a
-Source Specific Fan Insp-See Special Conditions ~~
-Heat Source Equip. & Controls Final-House Number
FRAMING Z ~ Final-Plumbing
Insp-See Special Conditions ~.e~! Final-MechanicaUHeating
Insp-See Special Conditions ~ f' Final-Insulation Certificate
-1 Hour Wall Final-Vapor Barrier Cert.
-Roof Final-Public Works Sign-Off
-Attic Venting Final-Barrier Free Access
-Window U Value Final-Fire Dept. Sign-Off
-Air Seat Final -Electrical (L&1)
-Door U Value Final -Building
-RafterlTruss Pos. Conn.
-Fire Blocking
INSULATION
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
City of Port Townsend P rtYTownsendtWA 98388
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 600 CLIFF ST Issued: 6!13!97
Parcel No: 989800006 Lot: Block:
Project: PEEMIT #~ BLD97-00060
SPECIAL CONDITIONS /RESTRICTIONS
1 . TEMP ERO & SEDM'T CONTL: See approved plans for Best Management Practices per
PTMC Engineering Design Standards. May require inspections PRIOR to any constriction.
2. FOUNDATION: See approved engineered pains for holdown type and location. 518" AB's
32" O.C. (3/4" AB's @ 32" O.C. @ P1.4 -see sheet S-1).
3. FLOOR FRAMING: Girder beams are DF #1.
4. FRAMING: All engineered elements constructed in the field require inspection prior to cover,
such as, holdowns and shear wall schedules, diaphram boundary nailing of blocking at
plateleave lines, top plate splices and drag connections.
5. FRAMING: Medical gas room (#116) requires 1 hour fire resistive construction for separation
from B occupancy.
~6. INSULATION: Medical gas room (#1 t6) separated from conditioned space per Nonresidential
Energy Code(NREC).
7. INSULATION: Insulation inspection as required by NREC.
8. VAPOR BARRIER: Vapor barrier certification required.
9. PLUMBING: 1" diameter service lines required per engineer.
10. FINAL: Compliance is required with attached Engineering Design Standard Detail T-16 (Curb
Ramps) to provide a landing from the ramp to the sidewalk.
11 . FINAL: Compliance is required with attached Engineering Design Standard Detail T-17
(Driveway Installation).
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
~~