Loading...
HomeMy WebLinkAboutBLD97-044' City of Port Townsend 640Wetef$ie`` Port Townsend, WA 96368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1370 MC CLELLAN Issued: 5/9/97 Parcel No: 948315301 Lpot: Block: Project: PEPMIT~ ~ BLD97-00044 -CONTRACTOR/OWNE NEIL CAVETTE PO BOX 1953 PORT TOWNSEND, WA 98368 NEIL CAVETTE PO BOX 1953 PORT TOWNSEND, WA 98368 Residential -New single family dwelling (1208 sq ft) with garage, porch and deck City Contact JLZ Construetlon Type/Occ UselOcc Load Type of work: NEW Construction Occupancy Type of use: SF Type 1: SN Group 1: R3 Load 1: 4 Census Category: t °1 Type 2: Group 2: U-t Load 2: 2 Estimated Value: $99,038.92 Type 3: Group 3: Load 3: Zoning: R-III SI Code: TYPe 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector TEMP EROSION & SDM'T CON -Reinforcement Insp-See Special Conditions -Anchor Botts FOOTINGS vi. (~ . l 7 /~ S -Vents -Setbacks -Crawl Access -Footings -Beam Pockets -Forms -Alt BWP Holdown Hdwr -Reinforcement FLOOR FRAMING Gl .~(p.c~~ ~, -Interior Footing -Girders -Porch/Deck Bay Piers ~loists -LIFER -Blocking FOUNDATION 5 ,' -Positive Connection Stem Wall -Girder to Concrete .~ms -Beam Pockets Call 48 hours before you dig for utility line locates 1-800-424-5555 Page t of 3 540 Water SUeat ~ City of Port Townsend Port Townsend, wA 98368 ' Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1370 MC CLELLAN Issued: 5!9/97 Parcel No: 948315301 Lot: Block: Protect: p~R11AiT ~E 13LD97-00044 Inspection Date Inspector Inspection Date Inspector -Treated Wood to Concrete -Air Seal -Anchor Bolts 8 Washers -Door U Value -FDN Vents -Fire Blocking PLUMBING -Weather Resistive Barrier Insp•See Special Conditions INSULATION -Rough-In (D-V-T 8 Cln Outs) 6~/p-C~ -Floor (R-30) -Water Supply ~~T ./Z.G~ f21 -Wall(R-19) •~~G~'7 S -Hose Bibs (bckflw pro. regd) ~~? ~S -Ceiling (R-38) QK -g~6 -water Heater -Baffles .~? ~ 7 ~J' -18" A.F.F. APOR BARRIER MECHANICAL /6_9 -Paint -Furnace Crawl Space - 6 Mil Poly -Remote Manifolded Fresh Air DRYWALL NAILING -Seismic Restraint -Walls -Dud Insulation -Ceiling -Whole House Fan -Interior Braced Wall Panels -Source Specific Fan -Garage/House Occ. Separation -Environmental Air Exhaust FINAL FRAMING Final-House Number Insp-See Special Conditions Final-Building -Walls fN1 ~P g61~L Final-Plumbing -Alternate Braced Wall Panel /Q~g~ ~~ Final-MechanicaUHeating -Ceiling ~ Final-Insulation Certificate -Roof iy~gSC`z • /Z-~ ,~C Final-Vapor Barrier Cert. -Attic Venting _-/p~~'J $ Final-Smoke Detectors -Window U Value FinahPublic Works Sign-Off -Window Safety Glazing Call 48 hours before you dig for utility line locates 1-800-424-5555 i Page 2 of 3 ` City of Port Townsend Port ownxnd, WA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 1370 MC CLELLAN Issued: 5/9197 Parcel No: 948315301 Lot: Block: Project: PERMIT # BLD97-00044 SPECIAL CONDITIONS I RESTRICTIONS 1 . TESC: See engineered plan. 2. PLUMBING: If water pressure exceeds 80 psi, pressure reduction valve required. 3. FRAMING: Blacking required for horizontal GWB joints ~ interior braced wall panels. GENERAL CONDITIONS 1. A separate electrical permit is required far any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. .4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 or 3 ~ Y 1~I `J • w