HomeMy WebLinkAboutBLD97-038
~ _' " City of Port Townsend
' Building and Community Development
610 Water street
Port Townsend, WA 88568
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1010 57TH ST
Parcel No; 972905101
Project:
--CONTRACTOR/OWNE
BOB LITTLE LITTLE 8. LITTLE
3534 MCNEILL STREET
PORT TOWNSEND, WA 98388
Issued: 4121197
Lot: Block:
PERMIT # BLD97-00038
WNE
GLEN E ARCHER
101D 57TH ST.
PORT TOWNSEND, WA 98368
Residential -Remodel existing bath and closet with addition of 334 sq ft of conditioned space for a total of 550 square
feet new space.
Cdy Contact: JLZ Construction TypelOec UsefOCC Load
Type of work: ADD Construction Occupancy
Type of use: SF Type 1; Sk Group 1: R~ Loatl t: 2
Census Category: 434 Type 2: Group 2: Losd 2:
Estimated Value: 540,000.00
Type 3: Group 3: Load 3:
Toning: R-I
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
DEMOLITION -Reinforcement
Insp-See Special Conditions ~ -Anchor Bolts
FOOTINGS 7' Zz • ~'~ ZS -Vents
Insp-See Special Conditions ~~ -Crawl Access
-Setbacks -Alt BWP Holdown Hdwr
-Footings FLOOR FRAMING ~ -j ,
w
-Forms -Girders
-Reinforcement -Joists
-Interior Footing -Shield Under Posts ~
-LIFER Nrt' -Positive Connection ,•
FOUNDATION -z~j-q~ ~ -Girder to Concrete l ~
-Stem Watl -Treated Wood to Concrete f
;ms -Anchor Bolts & Washers
Call 48 hours before you dig for utility line locates
1-800-424-5555
i
Page 1 of 3
City of Port Townsend
Building and Community development
spa Water Street 1- ~ - Z
Port Townsend, WA 88368
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUC710N SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1010 57TH ST Issued: 4121/97
Parcel No: 972905101 Lot: Block:
Pro;ed: PERMIT # 13LD97-00038
Inspection ate Inspector Inspection Date Inspector
-FDN Vents -Wall (R-19)
PLUMBING ,Z -Ceiling (R30)
Insp-See Special Conditions ~~ -Baffles
-Rough-In (D-V-T & Cln Outs) VAPOR BARRIER
-Water Supply -Paint
-Gas Supply ~- -Crawl Space - 6 Mil Poly
-Hose Bibs (bckflw pro. regd) DRYWALL NAILING
MECHANICAL Insp-See Special Conditions #~-
-Furnace ~~GG~Y'~G -Walls
-Fresh Air ~ ~ -Ceiling
-Dud Insulation ~} -Interior Braced Wall Panels
-Source Specific Fan C~ . ~9. ~7 S FINAL
-Environmental Air Exhaust Final-House Numher
FRAMING 7 ~ Final-Building
Insp•See Special Conditions ~y Final-Plumbing
-Walls Final-MechanicatiHeating
-Alternate Braced Wall Panel Final-Insulation Certificate
-Ceiling Final-Vapor Barrier Cert.
-Roof Final-Smoke Det. Througout
-Attic Venting Final-Fire Dept. Sign-Off
-Window U Value p ~~ -LPG
-Window Safety Glazing
-Air Seal
-Fire Blocking
-Weather Resistive Barrier
INSULATION
-Floor (R30)
Call 48 hours before you dig for utility line locates
1-800,424-5555
Page 2 or 3
City of Port Townsend saa water Street
Port TownserM, WA 98366
! ~
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1010 57TH ST Issued: Mz1/s7
Parcel No: 972905101 Lot: Block;
Proje~: PERMIT ## BLD97-00038
SPECIAL CONDITIONS /RESTRICTIONS
1 . DEMOLITION: Demolition covered under permit #MIS97-00010
2. FOOTINGS: Extended footing required for post, typical, if no beam pockets.
3. PLUMBING: If water pressure exceeds 80#, pressure reduction valve required.
4. FRAMING: Blocking required for horizontal joints at interior braced wall panel.
5. DRYWALL NAILING: Nailing ~ 7" o.c. for interior braced wall panel.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
>~
-_ i /
Y ` i