Loading...
HomeMy WebLinkAboutBLD97-002' City of Port Townsend ~Wa<"S4"` Port Townsend, WA 98768 r Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2426 SEAVIEW DR Parcel No: 993800015 Project: -CONTRACTOR/OWNE NELSON ~ FOSTER 31 COMBS PLACE PORT TOWNSEND, WA 98368 Issued: 2/14/97 lot: Block: ~ R A IT Jt BLD97-00002 STEVE RAFOTH 140 FIR CIRCLE PORT HADLOCK, WA 98339 New Single Family Residence (2665 sq ft), garage (639 sq ft), entry porch (58.5 sq ft), and back porch (411 sq ft) Ciy Cortiacl: JLZ Construdlon TypelOCC UsdOa Load Type of work NEW Construction Occupancy Typs of use: SF _ Type 1: SN Group t: RJ Load 1: 8 Cerreue Category. 101 Type 2: Group 2: U-t load 2 3 Estimated VaWa: 5250.000.00 Type 3: Group 3: Load 3: . ZaNng: SI Cade: R1 Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspection Date Inspector, TEMP EROSION 8 SDMT CON orms ~~ Insp-See Special Conditions .2 -y~ ~, ~_ ~~ -Reinforcement j FOOTINGS ~ -Anchor Bolts , -Setbacks -Vents -Footings -Crawl Access -Forms -Beam Pockets -Reinforcement -Lat. Restraint Holdown Hdwr -Interior Footing , ~d • - FLOOR FRAMING Q -Porch Bay Piers - -Girders -LIFER .y ~ 1 ~% S -Joists FOUNDATION 7~, `~ ~1' ~~J -Bridging t^~o-See Special Conditions -Shield Under Pasts .; Wall ~ -Positive Connection Ca114a hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 City of Port Townsend 640 WaterSt<eet Port Townsend, WA 98168 Building and Community Development `+. BUILDER'S PERMIT AND INSPECTION RECORD _ ~- THIS.CARD 8_APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2426 SEAVIEW DR Issued: 2/74/97 Parcel No: 993800015 Lot: Block: Project: B LD97-00002 Inspection Date Inspector In e i n Date Inspector -Giber to Concrete , / -INa -Beam Pockets -~ - -Treated Wood to Concrete FRAMING 5.23.97 S -Anchor Bolts & Washers Insp-See Special Conditions -FDN Vents Insp-See Special Conditions PLUMBING y, Z 3,k~ S -Walls -Rough-In -Lateral Restraint Panet -Vents -Seismic Anchors -Traps -Ceiling -Drains -Roof S$ GI ~'ZS' ~ -Clean-Outs -Attic Venting -Water Supply -Windows -Hose Bibs (Vacuum Break) -Window U Value -Pipe Insulation 7 b [, -Window Safety Glazing -Pressure Reduction Valve r ~ - 'r Seal -Water Heater resh Air Intake (14findew) ~ ~„~ ~{I -18" A.F.F. atterlTruss Pos. Conn. MECHANICAL .23 -G-j -Fire Blocking -Furnace -Firestopping -Exhaust INSULATION 5 •Z$ • ~ 7 1Z5 -Solid Fuel Appliance lnsp-See Special Conditions -Combustion Air -Floor CR-30) -Fresh Air ~{~ Zy C~ ail (R•19) -Seismic Restraint -Ceiling (R-30) -Duct insulation -Baffles -Whole House Fan VAPOR BARRIER Source Specific Fan -Paint Ca1148 hours before you dig for ' i ine loc~tas--~ 1-800-424-55 ~ (c_ r Pegezora S S 3t~• R7 Gity of Port Townsend Building and Community Development s,o weeer sweet Port Townsend, WA 88368 BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2426 SEAVIEW DR Parcel No: 993800015 Project: Inspection Date Inspector -Crawl Space - 6 Mil Poly ~; ,,L ~; ~',r DRYWALL NAILING - -Walis -Ceiling -Garage/House Occ. Separation ~ DRAINAGE ~ '. C,. ~,,: X ~ ~ ca_P ~ r r -Engineered Plan /~ FINAL ~ .~ ~._ ~ r ;' ' ~ - `^ Final-House Number f, Final-Building ~'IumtNng 4 : r: ~' ,~,i., Final=MechanicaUHeating Final-Insulation Certificate Final-Vapor Barrier Cert. ~ ~ ,. Final-Smoke Detectors : ' C. r1-, Fina6Public Wo n-Off ~ ~ ~-~~" -` ~,/, Final-Fin: pt. Sign-Off ~~ ~ \ Issued: 2H4/97 Lot: Block: PERMIT # BLD97-00002 ~' INT. 131n1P ri ElitiQlt~t)s~ off. ~ AS Ftza~t ~ ve:f~ I~6. t,-rrz/ rrrD L ~i3q~ SPECIAL CONDITIONS i RESTRICTIONS t . TESC: Applicant shalt submit an engineered erosion control and stormwater drainage plan prior to framing inspection. In the interim, applicant shall comply with the attached Small Parcel Minimum Requirements #1-4. 2. FOUNDATION: Engineered hold down schedule shown on foundation plan; location of hold downs indicated on floor plan. 3. FRAMING: Hold-Harmless Agreement shall be recorded and engineered erosion control and starmwater drainage plan to be submitted and approved prior to framing inspection per Shoreline Exemption LUP96-00082. 4 . FRAMING: See engineered shear wall schedule on floor plan. Shear load detail shown on last page of plans, Typical Section, for interior shear wail located at warkshop/garage. INSULATION: R-30 floor insulation speed on plans; R-19 required. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 City of Port Townsend ~°W°`°r~`~` Port Townsend, WA 88368 Building and Community Development - BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST QE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2426 SEAVIEW DR Issued: 2H4/97 Parcel No: 9938000f5 lot: Block: Project: BLD97-00002 PERMIT # GENERAL CONDITIONS 1. A separate electrical pertnk is required for any electrical work. 2. Reinspections are required after any cortections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. A-t building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 r Page 4 of 4