Loading...
HomeMy WebLinkAbout51st & Sheridan Utility ImprovementsI I I, BLK BLK I I EILK 30 I I I 29 I 63rd STRfiBT — O 8 6 4 'c I 8 6 4 LK 19 LtJ1 I I I EILK I I I K LL11 I I R0 I I I 1 ( I ao 0 40 lamaZ ' 1 inch 80 M I II 5 3 1. (r1 5 3 1 1 2nd STU" 4 z - - _ LIST OE SHEETS: 8 6 4 2 ( 8 6 4 2O Q , BLK 1 TITLE 18 I I 171 I I 16 I 2 51st STREETSHEET2 ' I I 3 SHERIDAN STREET 7 5 3 1 S I 4 DETAILS 3 S 3 1 5 GRANT STREET 6 CROSS SECTIONS61stMIT - 8 6 4 2 8 6 BLK 7 BLK e 6 WETLAND BUFFER BLK 9 100 FT LINE I I I VICINITY MAP 8c INDEX TO SHEETS NTANA ADDITION, SEC. 34, T31 N, R 1 W, W.M. I . EXP. DATE: 05 / 05 / 06 REVISIONS ZONE REV DESCRIPTION DATE APPROVED GENERAL CONDITIONS: 1. A preconstruction meeting shall be held with the City prior to the start of construction. 2. All workmanship and materials shall be in accordance with the City of Port Townsend Standards, the current edition of theStateofWashingtonStandardSpecificationsforRoad, Bridge and Municipal Construction, and any project— specific provisionsorconditions, and requirements. 3. Temporary erosion control measures are required and shall comply with the stormwater code, Chapter 5 of City EDSStandardsandWSDOT /APWA Specification 1 -07.15 as follows: a) Erosion control plans shall be submitted to the City, approved by the City, and implemented by the contractorpriortodistrubinganysoilonthesite. Submittal and approval of these plans shall precede any construction activity' on thesite. b) All permanent storage and retention /detention areas used as part of the temporary erosion control and waterpollution /flood activities and conveyance systems shall be cleaned of all silts, sand, and other materials following completion ofconstructionandthepermanentfacilitiesshallthenbecompletedincludingpermanentinfiltrationareas. 4. Horizontal and vertical controls /datum as adopted by the City shall be used, uless approved otherwise. 5. The contractor shall be fully responsible for the location and protection of all existing utilities. The contractor shall verifyallutilitylocatonspriortoconstructionbycallingUndergroundLocateat1- 800 -424 -5555 a minimum of 48 hours prior to any excavation work. 6. All non — ferrous pipe and services shall be installed with continuous tracer tape installed 12" to 18" under the final ground surface. The marker tape shall be 4" wide minimum plastice non — biogradable, metal core or backing marked and color codedfortheutilitytobemarkedandwhichcanbedetectedbyastandardmetaldetector. Tape shall be Terra Tape "D" or approved equal. Inaddition to tracer tape, force mains and curved mains shall have a 14 gauge coated copper wire, wrappedaroundthepipe, brought up, coated stripped, and tied off at the valve stem or manhole ring. The tape and wire shall befurnishedandinstalledbythecontractor. 7. Temporary street patching may be allowed with the approval of the City Engineer. Temporary street patching shall be asdescribedinChapter6oftheEDS. 8. The contractor shall provided a traffic control plan(s) for review and approval by the City Engineer in accordance with theManualonUniformTrafficeControlDevices (MUTCD). 9. The contractor shall have a copy of the approved plans and permits at the construction site at all times. 10. Special structures shall be installed per plans and manufacturers' recommendations. 11. All distrurbed areas shall receive temporary and permanent erosion control in the form of vegetation establishment such as grass seeding. A means shall be established to protect the permanent storm drain system prior to establishment of the permanent erosion control measures. These methods shall be included in the erosion and sediment control plans in accordance with Chapter 5 of these Standards. 12. Construction work hours shall be restricted to 7 AM to 6 PM, Monday through Friday, unless otherwise approved in writing. 13. The City Public Works Inspector shall be notified a minimum of 24 hours in advance of the need for an inspection. Everyeffortwillbemadetoaccommodatesame —day inspections if the City is notified before 8 AM. GENERAL CONDITIONS - -- WATER 1. The City shall be given 72 hours notice prior to scheduling a shutdown of any portion of the water system. The existingvalvemustbepressuretestedtoCitystandardspriortoconnection. If an existing valve fails to pass the test, the contractor shall make the necessary provisions to test the new line prior to connection to the existing system or install a newvalve. 2. The existing valves shall only be operated by City employees during construction. 3. During the construction of mains and services, the contractor shall cap, plug, or secure the ends of such lines whenever the project is shut down at the end of the day so that contaminates will not enter the lines. 4. All lines) shall be chlorinated and tested in conformance with the standard specifications. Dechlorintation will be done bycontractor. 5. All water mains shall be staked for grades and alignment. GENERAL CONDITIONS - -- WASTE WATER (SEWER) 1. All work and materials shall conform to the City and WSDOT /APWA Standard Specifications. 2. The City shall be notified 72 hours prior to scheduling a diversion of flows in the wastewater system. 3. During construction of mains and services, the contractor shall cap, plug, or secure the ends of such lines whenever the project is shut down at the end of day so that contaminates will not enter the lines. 4. All lines shall be tested in conformance with the Standard Specifications. Prior to final acceptance of all installations, theCityreservestherighttoconductaninspectionsofallmainlinesbytheuseoftelevisionequipment. 5. The City construction inspector shall be notified a minimum of 24 hours in advance of the time that a service connectiontoanexistingmainisneededsothatCityinspectionmaybescheduledforthework. The inspector shall be present at thetimeofthetap. 6. Prior to backfilling, all sewer lines and appurtenances shall be inspected and approved by the City's inspector. Approval shall not relieve the contractor for correction of any deficiencies and /opr failure as determined by subsequent testing andinspections. It shall be the contactor's responsibility to notify the City for the required inspections. 7. Approximate locations of existing facilities have been obtained from available records and are shown for convenience. Thecontactorshallberesponsibleforverificationoflocationsandtoavoiddamagetoanyadditonalutilitiesnotshown. If conflicts with existing utilities arise during construction, the contractor shall notify the public works inspector and any changesrequiredshallbeapprovedbythePublicWorksDirectorpriortocommencementofrelatedconstructionontheproject. 8. All sewer main extensions within the public right —of —way or in easements must be staked by survey for line and gradepriortostartingconstruction. GENERAL NOTES: 1. ALL CONSTRUCTION SHALL COMPLY WITH THE CITY OF PORT TOWNSEND ENGINEERING DESIGN STANDARDS. 2. SURVEY CONTROL PER CITY (NAVD88) STD MON 21 & 23 FOR COORDINATES BASIS OF BEARING (NAD83/91); HORIZONTAL PER EE ANDERSON SURVEY FOR PORT TOWNSEND. ANDERSON A S BUILT — — OWNER: 06/16/06CIVILENGINEERSLizBERMAN SURVEYORS 510 57th Street MONTANA ADD DEVELOPMENT PORT TOWNSEND, WA 98368 INDEX MAP, ORT TOWNSEND., WA 98368 NOTES & DETAILS 360) 385 -0398 DRWN BY RwR DESIGN BY MJA SCALE DATE: FEB 28, '05; 04/27/05;05/23/'05 SHEET I OF 6 i y s"a6 I CONSTRUCTION NOTES: I 0 " „ 2 AC /2 CSTC /8 „ AGG BASE PAVEMENT 30 30 O2 INSTALL 2 "AC /6 "AB DRIVEWAY 12' WIDE (TYPICAL) 3 INSTALL STREET NAME AND STOP SIGNS E-4 W W I 4 INSTALL 8" PVC SEWER & 6" LATERAL LINES WU O 18QAU5INSTALL8” PVC WATER MAIN & APPURTENANCESOw _ t- 4 p I O INSTALL 8" ADS STORM DRAIN /CATCH BASIN U Q I2 oo ry X X I 7 INSTALL INFILTRATOR TRENCH - DOUBLE L = 50 FT X`p WW O I— ~W Wf--1 I ri- W06 8 INSTALL 1/4" CSTC/ 95% NATIVE BASE FOR TRAIL I z ow O 0 , I 9 INSTALL BIOFILTRATION SWALE PER DETAIL SHT. 5 0o p ° I 10 INSTALL SURVEY MONUMENT PER DETAIL T -22 Q Z W tn~ O ~ tD f. 0 o + Z Q _j LL W ry 0i CLEARING LIMIT LINE 7- Q Q 0 CD > •- U INSTALL SILT FENCE Lo 3 STREET NAME & L 3 z A I STEP SIGN °_ w o CD So = i 4o Q i I , I 00 U CD U I — — — — — S s ti I 2 30 50 I 1 30 Ll z 0 d- LEGEND: co CL) EXISTING CONTOUR 36 m NEW PAVEMENT BENCH MARK MON NO.22 CITY MONUMENT PLAN 57th ST ® GISE ST ELEV. 29.28 (NAD 1983) 12 d- o 13 PROFILE mmm Hor 1 20' Vert 1 "= 4' 529 LFT (CL MH TO 14 STUB) ANDERSON CIVIL ENGINEERS SURVEYORS ORT TOWNSEND., WA 98368 P7 w (360) 385-0398 EXP. DATE: 05 / 05 / 06 i C)` s I U II` z w m: LD wryD Q Q z tq W00E- 1 0o cyi w30S + +> U-) Lo LLJ 15 CO LO mmm B# S,8 F In CLI wW U) CD Lv D N-i Lrn IH r000 U l mm t,-o m a? r,i i L MLoLn I Lo Lo 40 301 005 SHEET 2 OF 6 T<L -n 11 ins inc L- V 1 L_ JJ 1 1 W Q 3 W H m I Ld 16. 1 W I 9 +6 100 BEt NEW PAVE ENTj200102040 LJ C') W55100CLF13030I- m 1 inch 20 ft. H M RELO ATE X OCK Y ON O Q3P4 = 3i1IINSTALLPATHPRIVATEPUPETYfcn •+ I I I C31 1Q -70, IRTX z SEE D E T A I [ S H T 4 , Co 0 - - - 1 - - - GD.Ql,D 1T.1n!_I. ..D _ q 1 cn j 1,t = 20' Q L= 281'; P TECT 5 I . I g LD o 1 z 1 XISTING REESI o YPICA OUB E -T PICAL O z W 1/ L_. CLEARING LIMIT LINE I n + W% 3 I 1 / ` INSTALL SILT FENCE _ _ L - 0 w In + I a' I N TEI R MOVE REE D i° J P4 5 I I od : ' I NLY NEC S Y / / `fi <a CD i 1% 11 2 I 4 T PICAL 6 FOR N W CO ST, /i -- + c~ Wo •- 1/ 3 STREE NAME 3 + n z In 00 WM 1 J – – I – – X57 I Y 9 – — j WM – – M / / 1 , ER DAN + I / I .. 1/ O ( . 1 W m~ yoIlo < 11111111 11 .Z - y N00 °58'19" Nr 259.9311 1 1 — 3 N00 °58'19" 259.93 14 l– - - -- - -- – – – -- ------ - - - - -- - - -- - - -- 1S Js. 1 f u u I o cY), _ •n in 9 l o + c / n / SHT 11 TN WM I – w JLjCoL j Z Z -O d- W WM / I I _ UCLEARINGLIMITLINEN z o INSTALL SILT FENCE cn Q W d- J 0 Co Co z o (~/ °- AW TYPICAL d' C' d= 00 C5 CO Co CD F- 3 0 30 1 CD CO QF- OUBLE I 4 „ q Q I 1 r A z - 1 I // I W H o TYPICAL 6 Q -+ o H o a tL WATER MET SCFUT EI ATERAL 3 3 0 3¢ o M —I s-- # 0 - I 00 pp U% 0 - 0'- U (y) F- LLJI00tvLL110 +60 00 END NEW PAV ENT cn L!7 LL IU o 1 I `' 3 I 53,65 CL FS f o 0 D 0 0IIC,1 M_ w w - .-, W I Co pqq I I I ] I C") -q(/) I -o COZ`O1 oMUQ ( o od- qp I ( Q1 o 14 a ao 11 w U (-- LL ( Lf') o Lj F- I- Q 00 o m Ln Ln 't- o 0 , m Ln Ln -, 0 0 LLJ 00 cr") CD o ( z o C C m ( d- -' + row d- 0 00 O of Cho50wN d- d- C3, m cJ- d- d- z z 50 60 w 60 0 (.0 Co CowCENTERLINEGRADEOFNE + U U m coW = w PAVEMENT - FINISH GRADE U I? w co 8" CLASS 00 o r\ N N Q Lij z _ PVC WATER; + •+ r U U w LLJ o p > 00 (V t1) 520 LFT; CoL? d ° + + I o — O mot- > O Q EXISTIN GROUND + N — . -- 024 N O V-) N CL F PAVEMENT — 4 /° 3 F T MIN, COVER S =• _ w rn O .UO00 o v — _ +d- 40 -• — -" S=.0050 5 0 5u 1 iii S_.0120 M . U J E- z L.L o 0 r2 8" PVC SEWER; 4 No °o o 7 ° w LU(D w N 534 L F T `.° °. : Ln 5:.0 40 00 o rn rn o 8 ADS ST RM _ CO okN DRAIN; 16 LFT o LEGEND: 0 o n/ 2 PROFILE 6 '-N H 00 4 i LLJ EXISTING CONTOUR 60 W C o o 00 L(7 H o r 1 "= 20' I-1 ANDERSON Lf7 00 ., NEW PAVEMENT Cr) Ln 117 01 Q - . CU _ of Vert 1 = 4 0 00 01 `0 P ° WA CIVILCIVIL ENGINEERS L(7 00 -I d- - - - Z & SUNOTE. OJ 0 .0 f\ RVEYORS BENCH MARK C C -E- ('7 MON NO.22 CITY MONUMENT PLAN SEE SHEET 2 FOR CONSTRUCTION NOTES E PORT TOWNSEND., WA - 9836857thST ® GISE ST 3 ) EXP. DATE: 05 / 05 / 06 360/ 85- 0398 ELEV. 29.28 (NAD 1983) 3.g ° N- d- d 40d- i5 PP- \ /T FT1 11 ins ins i v 1 L I u L; 2 3 j C I TORT 2, City of Port Townsend - Public Works Department Standard Detail OF 6" MIN 2' MAX 3/4 FEMALE X METER 3/4 BRASS STREET ELBOW ' PROPERTY LINE 1" COPPER, NYLON BALL VALVE, MUELLER H14265, IOREQUIVLENT6" BRASS NIPPLE METER BOX - - PE 12" BRASS NIPPLE CLOSE A , IPP'LE 1 3/4" BRASS 3/4" BULLNOSE TEE SEE WATER SERVICE 3/4 BRASS I CONNECTION - SINGLE STREET ELBOW 3/4 FEMALE X METER BACK OF WALK SET METER AND BOX TO FINISH GRADE) Date: April 1997 Wj D.% "'°^ "' Water Service Connection Double Approved By File: E: \eng_std\standard\water Detail: W -2 TORT rJ City of Port Townsend - Public Works Department Standard Detail I1 PLAN COVER PLAN COVER REMOVED e ie 4 -S 8 "R N n 3 8" 1 10 -1 2' 1` VARIES 9-1/2' ' 1-1/2'•2' OR 3 ") ' 3-1/13-R COVER SECTION 9' 2' MIN 5 -1 ASPHALT CONCRETE 4-3/4 "R 4 "R i4 EXTENSION SECTION NOTES TORT ,.0 City of Port Townsend - Public Works Department A Standard Detail BUN D OA 0FLANGE PLUG BLIND FLANGE C OA 90' BEND TEE TEE BLIND FLANGE OR SMALLER SIZE PIPE 45' BEND 0 O @' GATE VALVE 22 1/2' BEND 11 1/4' BEND CROSS THRUST BLOCK — TABLE MIN. BEARING AREA AGAINST UNDISTURBED SOIL 1• MONUMENTS IN NON PAVED AREAS SHALL BE PIPE SIZE A e, 1. 41' SQ i- ... 3" ABOVE GRADE. 0 FT' 4" Y 2• ALL MONUMENTS SHALL BE PRECAST CONC 1 1 1 NONE WITH REBAR AND 2 -1/2" DIA BRASS CAP. 4 4 e" • . MONUMENT CASE 3• MONUMENT CASE AND RISER SECTION SHALL NONE I 7 6 BE CAST IRON PER ASTM -A48. CLASS 30, 2 12'R 4 2 -1/2" DIA DOMED WITH BITUMINOUS COATING. 10 6 3 BRASS CAP 4• COVER SHALL BE DUCTILE IRON PER ASTM - 12" CONCRETE BASE 14 9 A536. GRADE 80- 55 -06. WITH BITUMINOUS 3 CLASS 4000) 14" 22 COATING. 12 6 12-MIN /8 REBAR S. LEGEND ON COVER SHALL BE 1/8' RAISED 29 25 8 INTEGRALLY CAST LETTERS 1' HIGH WITH 16 18" 31 A MIN FACE WIDTH OF 3/16 '. 10 1 5 a. 20" 45 39 24 PRECAST CONCRETE MONUMENT 24 22" 54 a ' CLASS 4000 CONC) 15 8 29 6" SQ 64 56 35 18 SECTION 35 28" 87 76 Date: April 1997 24 N" +" wd Survey Monument 87 55 28 14 55 36" 175 125 78 40 20 Approved By: 42" 197 171 107 55 27 107 Detail: T -22 257 223 140 File: E:\ eng_std\standard\transpo 36 140 FL X MJ) 16 "X8 "X4 "MIN CONCRETE BLOCK 6" DUCTILE IRON TORT ,.0 City of Port Townsend - Public Works Department A Standard Detail BUN D OA 0FLANGE PLUG BLIND FLANGE C OA 90' BEND TEE TEE BLIND FLANGE OR SMALLER SIZE PIPE 45' BEND 0 O @' GATE VALVE 22 1/2' BEND 11 1/4' BEND CROSS THRUST BLOCK — TABLE MIN. BEARING AREA AGAINST UNDISTURBED SOIL SQUARE FEET PIPE SIZE 0 FT' @ FT' FT' @ FT2 0 FT' 0 FT' 4" 3 1 1 1 1 NONE 6" 4 4 2 1 1 NONE 8" 7 6 4 2 1 4 t0" 11 10 6 3 2 6 12" 16 14 9 5 3 9 14" 22 19 12 6 3 12 16" 29 25 16 8 4 16 18" 36 31 20 10 1 5 20 20" 45 39 24 13 6 24 22" 54 47 29 15 8 29 24" 64 56 35 18 9 35 28" 87 76 48 24 12 1 48 30" 101 87 55 28 14 55 36" 175 125 78 40 20 78 42" 197 171 107 55 27 107 48" 257 223 140 71 36 140 NOTES: 1. BEARING AREA OF CONCRETE THRUST - BLOCK BASED ON 200 PSI PRESSURE AND SAFE SOIL- BEARING LOAD OF 2,000 POUNDS PER SQUARE FOOT. 2. AREAS MUST BE ADJUSTED FOR OTHER PIPE SIZES, PRESSURES, AND SOIL CONDITIONS. 3. CONCRETE BLOCKING (CLASS 3000) SHALL BE CAST IN PLACE AND HAVE A MINIMUM OF 1/4 SQUARE FOOT BEARING AGAINST THE FITTING. 4. BLOCK SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING OF JOINT. 5. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL TEST PRESSURE UNDER ALL CONDITIONS OF SERVICE. 6. MINIMUM ROD DIAMETER SHALL BE 3/4" ASTM A -307 WITH 36KSI YIELD STRENGTH. Date: April 1997 N' Da1i p""'"" Horizontal Thrust Blocks Approved By: File: E: \eng-std\standsrd\water Detail: W -8 Date: April 1997 Approved By: File: E :\eng_std\standard\water TORT rA City of Port Townsend - Public Works Department Standard Detail GUARD POST c--- SEE NOTE 2 O BREAK AWAY FLANGE o 0 36" 28" GUARD POST 18" J-7;4-L SEE NOTE 1 ELEVATION PLAN FIRE HYDRANT GUARD POST SEE NOTES 1 ANO 2) NOTES: 1 GUARD POSTS SHALL BE 6' LONG, 8 -IN DIAMETER 18" PRECAST CONCRETE OR G' LONG, 6' DIAM SCH 40, CONCRETE FILLED CLASS 52 STEEL PIPE. PAINTED WITH TWO COATS OF "RUST- O -LEUM" NO. 2766, HI GLOSS YELLOW PAINT. 42" 2 TOP OF GUARD POST SHALL BE LEVEL WITH TOP OF I FIRE HYDRANT OR 30" IF NOT ON LEVEL GROUND. I3 VALVE MARKER POST SHALL BE 42" PORTABLE TRAFFIC DELINEATOR POST W/TWO REFLECTOR STRIPS. THEY SHALL BE FURNISHED NEW AND UNUSED AND BURIED 24" DEEP, TO LEAVE 18" EXPOSED AS A MARKER POST THE LETTER "V' AND THE DISTANCE TO THE VALVE VALVE MARKER POST SHALL BE STENCILED ON THE POST WITH 2" HIGH NUMERALS, WITH BLACK ENAMEL PAINT. SEE NOTES 3, 4 AND 5) 4 VALVE MARKER POSTS SHALL BE INSTALLED FOR ALL VALVES LOCATED IN UNIMPROVED OR UNPAVED AREAS. VALVE MARKER POSTS SHALL BE SET IN A SAFE AND REASONABLY CONSPICUOUS LOCATION. 5 VALVE MARKER POSTS ARE NOT REQUIRED FOR AUXILIARY HYDRANT VALVES. Date: April 1997 -R-w- h Fire Hydrant Guard Post Ap ved By: and Valve Marker Post Approved By: Ti T Dot rY File: EAeng_std\standard\water Detail: -11 UPPER 6" 95% COMPACTION) OR MATCH EX, PVMT) PRIMARY .NEIGHBORHOOD CONNECTOR SAW CUT — TYPICAL FOR EXISTING PAVEMENT Geotextile FINAL SAND BEDDING LIFT 6" TO 12" ABOVE CROWN) 2% cross slope or crown NATIVE MATERIAL required for drainage COMPACTED TO 90% 4 MIN SAND BEDDING TYPICAL TRENCH IN PAVEMENT 1/4" compacted crushed rock (95% M.P.D)., 2 „ —4 NS Pit run (or any non— organic fill), 4 "--6" (may be reduced if adequate subgrade exists) Subgrade compacted to 95% M.P.D. AS BUILT - -- 0616/06 MONTANA ADD DEVELOPMENT WATER DETAILS 8c MISC. DETAILS SIZE FSCM NO. DWG NO. REV SCALE 20 DATE: FEB 28, '05: 04/27/05:05/23/'05 SHEET 4 OF 6 TORT r City of Port Townsend - Public Works Department DoT Standard Detail MUELLER CENTURY 4" NST STEAMER PORT FIRE HYDRANT 4" STORTZ ADAPTER TWO 2 1/2" MAX 4 ", NST PORTS MIN 3" 100 18" MIN, 28" MAX 3" VALVE -BOX 7 CU. FT. MIN WASHED GRAVEL PASSING 1 -1/2" AND RETAINED ON 1/0 MESH FOR DRAIN CAST IRON TEE, 5s:' rt MEGA -LUG WITH 6" FLANGE CONCRETE BLOCKING TO ' {' r' SIDE OUTLET BE PLACED AGAINST ' UNDISTURBED SOIL (TYP) ' 3 . • . :~ CONCRETE TO BE PLACED BLOCKING AGAINST UNDISTURBED SOIL (TYP) 6" GATE VALVE FL X MJ) 16 "X8 "X4 "MIN CONCRETE BLOCK 6" DUCTILE IRON PIPE CLASS 52 MJ WITH RESTRAINT CEMENT LINED OR C -900 PVC 3/4" ALL THREAD ROD Date: April 1997 Approved By: File: E :\eng_std\standard\water TORT rA City of Port Townsend - Public Works Department Standard Detail GUARD POST c--- SEE NOTE 2 O BREAK AWAY FLANGE o 0 36" 28" GUARD POST 18" J-7;4-L SEE NOTE 1 ELEVATION PLAN FIRE HYDRANT GUARD POST SEE NOTES 1 ANO 2) NOTES: 1 GUARD POSTS SHALL BE 6' LONG, 8 -IN DIAMETER 18" PRECAST CONCRETE OR G' LONG, 6' DIAM SCH 40, CONCRETE FILLED CLASS 52 STEEL PIPE. PAINTED WITH TWO COATS OF "RUST- O -LEUM" NO. 2766, HI GLOSS YELLOW PAINT. 42" 2 TOP OF GUARD POST SHALL BE LEVEL WITH TOP OF I FIRE HYDRANT OR 30" IF NOT ON LEVEL GROUND. I3 VALVE MARKER POST SHALL BE 42" PORTABLE TRAFFIC DELINEATOR POST W/TWO REFLECTOR STRIPS. THEY SHALL BE FURNISHED NEW AND UNUSED AND BURIED 24" DEEP, TO LEAVE 18" EXPOSED AS A MARKER POST THE LETTER "V' AND THE DISTANCE TO THE VALVE VALVE MARKER POST SHALL BE STENCILED ON THE POST WITH 2" HIGH NUMERALS, WITH BLACK ENAMEL PAINT. SEE NOTES 3, 4 AND 5) 4 VALVE MARKER POSTS SHALL BE INSTALLED FOR ALL VALVES LOCATED IN UNIMPROVED OR UNPAVED AREAS. VALVE MARKER POSTS SHALL BE SET IN A SAFE AND REASONABLY CONSPICUOUS LOCATION. 5 VALVE MARKER POSTS ARE NOT REQUIRED FOR AUXILIARY HYDRANT VALVES. Date: April 1997 -R-w- h Fire Hydrant Guard Post Ap ved By: and Valve Marker Post Approved By: Ti T Dot rY File: EAeng_std\standard\water Detail: -11 UPPER 6" 95% COMPACTION) OR MATCH EX, PVMT) PRIMARY .NEIGHBORHOOD CONNECTOR SAW CUT — TYPICAL FOR EXISTING PAVEMENT Geotextile FINAL SAND BEDDING LIFT 6" TO 12" ABOVE CROWN) 2% cross slope or crown NATIVE MATERIAL required for drainage COMPACTED TO 90% 4 MIN SAND BEDDING TYPICAL TRENCH IN PAVEMENT 1/4" compacted crushed rock (95% M.P.D)., 2 „ —4 NS Pit run (or any non— organic fill), 4 "--6" (may be reduced if adequate subgrade exists) Subgrade compacted to 95% M.P.D. AS BUILT - -- 0616/06 MONTANA ADD DEVELOPMENT WATER DETAILS 8c MISC. DETAILS SIZE FSCM NO. DWG NO. REV SCALE 20 DATE: FEB 28, '05: 04/27/05:05/23/'05 SHEET 4 OF 6 Q jsC Jill 2 U w L J ONU . o o + o s 0 3 - 11 +65, 0 C #1 END SEWER ON Oj In Q + z O l1 —+ I LI 0i U Ld 1 I 1 I ° x` T T 0,<\ ST. 1 S I 1 I m 1 GRANT ST. (vacated) 11 j 1s 1 O 13 14 I f CD CD IV% ww I 4 W >-- SZQ ry 3 11 - U, — " I W TYPICAL ff i ti j i IrN W C) z J LL ry LATERAL 3 30 t i u I i o ao i 1 '91 In Kv I 5U Grant St - 51st St to 53rd St NS 13 Q CENTER LINE GRADE OF NEW AS BUILT 06/16/06ANDERSON so 0 10 20 40 J. WAS o, CIVIL ENGINEERS CONSTRUCTION NOTES: 30 RANT O p" SURVEYORSOG PORT TOWNSEND, WA 98368 51 st St to 52nd St 7663 PLAN Sc PROFILE PORT TO WNSEND, WA 98368 50 I DRWN BY RWR I I z I O 2„ AC/2" CST( /8" AGG BASE PAVEM I W SCALE 20 DATE: NOV 10, 2005; 11/22/'05;1/03/'08 SHEEP 5 OF 6 i inch = zo tt. ry U 2LL- O INSTALL 2 AC /6 AB DRIVEWAY 12 WIDE (TYPICAL) o z i O NoRrx 1 = 20' I O3 INSTALL STREET NAME AND STOP SIGNS LLJ w 00 cn z w 0 0 m OU LLJ I z 3 I z I 4 INSTALL 8" PVC SEWER & 6" LATERAL LINESO LO J= W V J Oo L0 I---I E 00 LL- F-- L0 __I II 5 TO 10 SEE SHEET 2OQP4NCOCL 0 00 0 S==.01 48 00 w3 - 11 +65, 0 C #1 END SEWER ON Oj In Q + z O l1 —+ I LI 0i U Ld 1 I 1 I ° x` T T 0,<\ ST. 1 S I 1 I m 1 GRANT ST. (vacated) 11 j 1s 1 O 13 14 I f CD CD IV% ww I 4 W >-- SZQ ry 3 11 - U, — " I W TYPICAL ff i ti j i IrN W C) z J LL ry LATERAL 3 30 t i u I i o ao i 1 '91 In Kv I 30 XISTING GROUND N CL OF PAVEMENT 50 , SEE DETAIL SHEET 2 40 1 ft ditch; 311 Slope (TYP) 2 FT 4' AGG SHOULDER (TYPICAL); COMPACTED 7 7 5 5 2' WATER SERVICE PROVIDE 36' OVER CROSS _SECTION 30 CENTER LINE ELEVA TION INSTALL 6' SEWER LATERAL - 5' DEPTH 2 PL (TYPICAL) 1.5' INSTALL UTILITY TRENCH 2' WIDE/ 2' CONDUIT TYPICAL) BOTTOM EL.= 96.66 5U Grant St - 51st St to 53rd St NS 13 CENTER LINE GRADE OF NEW AS BUILT 06/16/06ANDERSONOWNER: E J. WAS o, CIVIL ENGINEERS PAVEMENT - FINISH GRADE RANT O p" SURVEYORSOG PORT TOWNSEND, WA 98368 51 st St to 52nd St 7663 PLAN Sc PROFILE PORT TO WNSEND, WA 98368 50 DRWN BY RWR 360) 385 -0398 z DESIGN BY MJA EXP. DATE: 05 / 05 /-0-6j SCALE 20 DATE: NOV 10, 2005; 11/22/'05;1/03/'08 SHEEP 5 OF 6 w o z r O w LLJ w 00 cn z w 0 0 m Co w CO CD U) LO Oo CD T- 00 o `_ LL- 0 00 0 S==.01 48 40 S= .0148 O w 6„ PVC SEWER; ry CO 265 LFT 0 U -Id- 30:E 0r z 1 0 LEGEND: 12 PROFILE00 rn oo 4 EXISTING CONTOUR 60 n Hor 1 = 20 NEW PAVEMENT Vert 1 „ = 4' BENCH MARK MON NO.22 CITY MONUMENT PLAN 57th ST ® GISE ST ELEV. 29.28 (NAD 1983) 30 XISTING GROUND N CL OF PAVEMENT 50 , SEE DETAIL SHEET 2 40 1 ft ditch; 311 Slope (TYP) 2 FT 4' AGG SHOULDER (TYPICAL); COMPACTED 7 7 5 5 2' WATER SERVICE PROVIDE 36' OVER CROSS _SECTION 30 CENTER LINE ELEVA TION INSTALL 6' SEWER LATERAL - 5' DEPTH 2 PL (TYPICAL) 1.5' INSTALL UTILITY TRENCH 2' WIDE/ 2' CONDUIT TYPICAL) BOTTOM EL.= 96.66 5U Grant St - 51st St to 53rd St NS 13 AS BUILT 06/16/06ANDERSONOWNER: J. WAS o, CIVIL ENGINEERS 5oBSRnAStreetG RANT STREET p" SURVEYORSOG PORT TOWNSEND, WA 98368 51 st St to 52nd St 7663 PLAN Sc PROFILE PORT TO WNSEND, WA 98368 DRWN BY RWR 360) 385 -0398 DESIGN BY MJA EXP. DATE: 05 / 05 /-0-6j SCALE 20 DATE: NOV 10, 2005; 11/22/'05;1/03/'08 SHEEP 5 OF 6