HomeMy WebLinkAbout35th St. Jackman to Haines Waterline Extensions~ h US Ln M 4 y SEE DETAIL STA 7 +28 LC a U WATERMAIIV EXTENSION nnnnnnnn nn n. VL10D L7D0L7D 1 i, L' X1.11, L' 1J 1 ' t../ 1 i, . 1 L J L 1 d lT 1 1 N ~ N L O CA TED IN SECTION 3, TOWNSHIP 30 NORTH, RANGE 1 WEST, W.M. , tI N CITY OF POR T TO'WNSEND Q o NQ EXISTING GROUND + o SURFACE Q , 1) A PRECONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE START OF CONSTRUCTION. 2) ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY OF PORT TOWNSEND STANDARDS, THE CURRENT EDITION OF THE STATE WATERLINE PROFILE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL 510 CONSTRUCTION, AND ANY PROJECT — SPECIFIC SPECIAL PROVISIONS OR CONDITIONS AND REQUIREMENTS. 3) TEMPORARY EROSION CONTROL MEASURES ARE REQUIRED AND SHALL COMPLY WITH THE STORMWATER CODE, CHAPTER 5 OF THESE STANDARDS AND WSDOT /APWA SPECIFICATION 1 -07.15 AS FOLLOWS: A) EROSION CONTROL PLANS SHALL BE SUBMITTED TO THE CITY, APPROVED HORIZONTAL SCALE 1 " = 100' VERTICAL SCALE 1 " = 10' ANY SOIL ON THE SITE. SUBMITTAL AND APPROVAL OF THESE PLANS SHALL PRECEDE ANY CONSTRUCTION ACTIVITY ON THE SITE. 500 B) ALL PERMANENT STORAGE AND RETENTION /DETENTION AREAS USED AS PART OF THE TEMPORARY EROSION CONTROL AND WATER POLLUTION /FLOOD ACTIVITIES AND CONVEYANCE SYSTEMS SHALL BE CLEANED OF ALL SILTS, SAND AND OTHER MATERIALS FOLLOWING COMPLETION OF CONSTRUCTION AND THE PERMANENT FACILITIES SHALL THEN BE COMPLETED INCLUDING PERMANENT INFILTRATION AREAS. 4) HORIZONTAL AND VERTICAL CONTROLS /DATUM AS ADOPTED BY THE CITY SHALL BE USED, UNLESS APPROVED OTHERWISE. 5) THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING UNDERGROUND LOCATE AT 490 1- 800 - 424 -5555 A MINIMUM OF _48 HOURS PRIOR TO ANY EXCAVATION WORK. 6) ALL NON— FERROUS PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" TO 18" UNDER THE FINAL GROUND SURFACE. THE MARKER TAPE SHALL BE 4" WIDE MINIMUM PLASTIC NON— BIODEGRADABLE, METAL CORE OR BACKING MARKED AND COLOR CODED FOR THE UTILITY TO BE MARKED AND WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. IN ADDITION TO TRACER TAPE, FORCE MAINS AND CURVED MAINS SHALL HAVE A 14 GAUGE COATED COPPER WIRE, WRAPPED AROUND THE PIPE, BROUGHT UP, COATING STRIPPED, AND TIED OFF AT THE VALVE STEM 0R ,, MANHOLE RING. THE TAPE AND WIRE SHALL BE FURNISHED AND INSTALLED BY THE' CONTRACTOR. 3' MIN COVER OVER 7) TEMPORARY STREET PATCHING MAY BE ALLOWED WITH THE APPROVAL OF THE CITY ENGINEER. TEMPORARY STREET PATCHING SHALL BE AS DESCRIBED IN CHAPTER 6. V'IVD THE CONTRACTOR SHALL PROVIDE A TRAFFIC CONTROL PLAN(S) FOR REVIEW DATUM ELEY APPROVAL BY THE CITY ENGINEER IN ACCORDANCE WITH THE MANUAL ON TOP OF PIPE FILL AS REQUIRED NEW 8" PVC C900 MAIN TRENCH PER 2 8 +06, 7 +00 6 +00 5 +00 B NEW SERVICE r METER AND VALVE`l STA 8+ 15 SEE DETAIL 2 STA 8 +25 2 NEW HOME U? LEGEND f wV i WATER VALVE Ott WATER METER 1 W11 NEW FIRE HYDRANT EXISTING 1' CONTOUR w WATER MAINZF: 1 P UNDERGROUND POWER EASEMENT LINE 50 25 0 50 100 J Y THIS PROJECT IS LOCATED IN SECTION 3, TOWNSHIP 30 NORTH, RANGE 1 WEST, W. M., IN THE CITY OF PORT TOWNSEND. ON THE UNREDUCED DRAWING THIS RECTANGLE dS ONE INCH SQUARE D /01 /30 /S03 /YESBERGER /WATER2.DWG HORIZONTAL SCALE 1" =50' VERTICAL SCALE 1" = 5' 4 +00 REVISIONS DETAIL NUMBER DETAIL REFERENCES DATE DESCRIPTION BALLOON REFERENCES TO DETAILS INCLUDE TWO NUMBERS. THE BOTTOM NUMBER IS THE NUMBER2OFTHEPAGEWHERETHEDETAILMAYBEFOUND. THE TOP NUMBER IS THE NUMBER OF THAT DETAIL. PAGE NUMBER 3 +00 2 +00 1+00 cKol 3 +0 2+00- 00 1 P P 35TH STREET 45° ELBOWS W/ 5THRUSTBLOCKINGPER2 l r 33RD STREET NOTES 0 475.00 iNIFORM TRAFFIC CONTROL DEVICES (MUTCD). Ntr' Tc 9) THE CONTRACTOR SHALL HAVE A COPY OF THE APPROVED PLANS AND PERMITS r'T THE CONSTRUCTION SITE AT ALL TIMES. ntS, 10) SPECIAL STRUCTURES SHALL BE INSTALLED PER PLANS AND MANUFACTURERS' RECOMMENDATIONS. 0 +00 11) ALL DISTURBED AREAS SHALL RECEIVE TEMPORARY AND PERMANENT EROSION CONTROL IN THE FORM OF VEGETATION ESTABLISHMENT SUCH AS GRASS SEEDING. A MEANS SHALL BE ESTABLISHED TO PROTECT THE PERMANENT STORM DRAIN Ll SYSTEM PRIOR TO ESTABLISHMENT OF THE PERMANENT EROSION CONTROL MEASURES. THESE METHODS SHALL BE INCLUDED IN THE EROSION AND SEDIMENT CONTROL PLANS IN ACCORDANCE WITH CHAPTER 5 OF THESE STANDARDS 12) CONSTRUCTION WORK HOURS SHALL BE RESTRICTED TO 7 A.M. T M' P. M. CO TRACTOR TO FIELD CONFIRM MONDAY THROUGH FRIDAY, UNLESS OTHERWISE APPROVED IN WRITING. CATION OF EXISTING END OF WATER MAIN FOR 13) THE CITY PUBLIC WORKS INSPECTOR SHALL BE NOTIFIED A MINIMUM OF INSTALLATION OF 8" GATE 24 HOURS IN ADVANCE OF THE NEED FOR AN INSPECTION. EVERY EFFORT WILL VALVE AT START OF EXTENSION , BE MADE TO ACCOMMODATE SAME —DAY INSPECTIONS IF THE CITY IS NOTIFIED BEFORE 8 AM. 14) ALL PUBLIC WORKS INSPECTIONS SHOULD BE SCHEDULED BETWEEN THE HOURS PER 3 OF 7.•30 AM AND 3:30 PM. 1%1aT-,.-S JAN 1 2000 r) tq0/ 1VxV1 l I,IA Z M 4 i( L/ n!E - - - - - _ - - - - -- - - - - Uri ,r o.W. 7a N / g / —.r S 4yo-4eA- m N . e CALL 48 HOURS BEFORE YOU DIG 1 -800- 424 -5555 FOR UNDERGROUND UTILITY LOCATE SERVICE COVER PLAN AND PROFILE APPROVED N017CE: Plans are approved axs+t kW Orr Nrors of omissions. AM w * must ' pass inspection in conformance, with ap oti0rltr Datt: Porn* rr PT SHEET I OF GENERAL CONDITIONS THE FOLLOWING TEXT IS TAKEN DIRECTLY FROM THE CITY OF PORT TOWNSEND ENGINEERING DESIGN STANDARD MANUAL: 1) A PRECONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR TO THE START OF CONSTRUCTION. 2) ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE CITY OF PORT TOWNSEND STANDARDS, THE CURRENT EDITION OF THE STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL 510 CONSTRUCTION, AND ANY PROJECT — SPECIFIC SPECIAL PROVISIONS OR CONDITIONS AND REQUIREMENTS. 3) TEMPORARY EROSION CONTROL MEASURES ARE REQUIRED AND SHALL COMPLY WITH THE STORMWATER CODE, CHAPTER 5 OF THESE STANDARDS AND WSDOT /APWA SPECIFICATION 1 -07.15 AS FOLLOWS: A) EROSION CONTROL PLANS SHALL BE SUBMITTED TO THE CITY, APPROVED BY THE CITY, AND IMPLEMENTED BY THE CONTRACTOR PRIOR TO DISTURBING ANY SOIL ON THE SITE. SUBMITTAL AND APPROVAL OF THESE PLANS SHALL PRECEDE ANY CONSTRUCTION ACTIVITY ON THE SITE. 500 B) ALL PERMANENT STORAGE AND RETENTION /DETENTION AREAS USED AS PART OF THE TEMPORARY EROSION CONTROL AND WATER POLLUTION /FLOOD ACTIVITIES AND CONVEYANCE SYSTEMS SHALL BE CLEANED OF ALL SILTS, SAND AND OTHER MATERIALS FOLLOWING COMPLETION OF CONSTRUCTION AND THE PERMANENT FACILITIES SHALL THEN BE COMPLETED INCLUDING PERMANENT INFILTRATION AREAS. 4) HORIZONTAL AND VERTICAL CONTROLS /DATUM AS ADOPTED BY THE CITY SHALL BE USED, UNLESS APPROVED OTHERWISE. 5) THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING UNDERGROUND LOCATE AT 490 1- 800 - 424 -5555 A MINIMUM OF _48 HOURS PRIOR TO ANY EXCAVATION WORK. 6) ALL NON— FERROUS PIPE AND SERVICES SHALL BE INSTALLED WITH CONTINUOUS TRACER TAPE INSTALLED 12" TO 18" UNDER THE FINAL GROUND SURFACE. THE MARKER TAPE SHALL BE 4" WIDE MINIMUM PLASTIC NON— BIODEGRADABLE, METAL CORE OR BACKING MARKED AND COLOR CODED FOR THE UTILITY TO BE MARKED AND WHICH CAN BE DETECTED BY A STANDARD METAL DETECTOR. TAPE SHALL BE TERRA TAPE "D" OR APPROVED EQUAL. IN ADDITION TO TRACER TAPE, FORCE MAINS AND CURVED MAINS SHALL HAVE A 14 GAUGE COATED COPPER WIRE, WRAPPED AROUND THE PIPE, BROUGHT UP, COATING STRIPPED, AND TIED OFF AT THE VALVE STEM 0R ,, MANHOLE RING. THE TAPE AND WIRE SHALL BE FURNISHED AND INSTALLED BY THE' CONTRACTOR. 480 7) TEMPORARY STREET PATCHING MAY BE ALLOWED WITH THE APPROVAL OF THE CITY ENGINEER. TEMPORARY STREET PATCHING SHALL BE AS DESCRIBED IN CHAPTER 6. V'IVD THE CONTRACTOR SHALL PROVIDE A TRAFFIC CONTROL PLAN(S) FOR REVIEW DATUM ELEY APPROVAL BY THE CITY ENGINEER IN ACCORDANCE WITH THE MANUAL ON 0 475.00 iNIFORM TRAFFIC CONTROL DEVICES (MUTCD). Ntr' Tc 9) THE CONTRACTOR SHALL HAVE A COPY OF THE APPROVED PLANS AND PERMITS r'T THE CONSTRUCTION SITE AT ALL TIMES. ntS, 10) SPECIAL STRUCTURES SHALL BE INSTALLED PER PLANS AND MANUFACTURERS' RECOMMENDATIONS. 0 +00 11) ALL DISTURBED AREAS SHALL RECEIVE TEMPORARY AND PERMANENT EROSION CONTROL IN THE FORM OF VEGETATION ESTABLISHMENT SUCH AS GRASS SEEDING. A MEANS SHALL BE ESTABLISHED TO PROTECT THE PERMANENT STORM DRAIN Ll SYSTEM PRIOR TO ESTABLISHMENT OF THE PERMANENT EROSION CONTROL MEASURES. THESE METHODS SHALL BE INCLUDED IN THE EROSION AND SEDIMENT CONTROL PLANS IN ACCORDANCE WITH CHAPTER 5 OF THESE STANDARDS 12) CONSTRUCTION WORK HOURS SHALL BE RESTRICTED TO 7 A.M. T M' P. M. CO TRACTOR TO FIELD CONFIRM MONDAY THROUGH FRIDAY, UNLESS OTHERWISE APPROVED IN WRITING. CATION OF EXISTING END OF WATER MAIN FOR 13) THE CITY PUBLIC WORKS INSPECTOR SHALL BE NOTIFIED A MINIMUM OF INSTALLATION OF 8" GATE 24 HOURS IN ADVANCE OF THE NEED FOR AN INSPECTION. EVERY EFFORT WILL VALVE AT START OF EXTENSION , BE MADE TO ACCOMMODATE SAME —DAY INSPECTIONS IF THE CITY IS NOTIFIED BEFORE 8 AM. 14) ALL PUBLIC WORKS INSPECTIONS SHOULD BE SCHEDULED BETWEEN THE HOURS PER 3 OF 7.•30 AM AND 3:30 PM. 1%1aT-,.-S JAN 1 2000 r) tq0/ 1VxV1 l I,IA Z M 4 i( L/ n!E - - - - - _ - - - - -- - - - - Uri ,r o.W. 7a N / g / —.r S 4yo-4eA- m N . e CALL 48 HOURS BEFORE YOU DIG 1 -800- 424 -5555 FOR UNDERGROUND UTILITY LOCATE SERVICE COVER PLAN AND PROFILE APPROVED N017CE: Plans are approved axs+t kW Orr Nrors of omissions. AM w * must ' pass inspection in conformance, with ap oti0rltr Datt: Porn* rr PT SHEET I OF R J 8" GA' BLIND FLANGE W/ THRUST BLOCKING BLIND FLANGE w / njo/ /cT Ql nl-vwl- C900 PVC MIN 3 " CROSS UST BLOCKING 1 VALVES AND CROSS 2 ® 35th AND JACKMAN SCHEMATIC ONLY — NO SCALE 8" C900 PVC MAIN SADDLE TAP FOR SINGLE SERVICE 1" DOMESTIC LINE 5 MIN PER 7 MIN CLEARAN 2 8 "x8 "x6" TEE W/ O THRUST BLOCKING 8" GATE VALVE PFs,,, , W/ THRUST BLOCKING FIRE HYDRANT BLIND FLANGE W/ PER 2 THRUST BLOCKING 6" GATE VALVE 2 END OF MAIN EXTENSION 2 DETAIL SCHEMATIC ONLY — NO SCALE CAST IRON VAt VE BOX 18" x 24' WITH LID MARKED WATER 2" IRON BODY GATE VALVE, MUELLER A- 2360 -08, OR 1 1/2 GRINNEL BRASS HAND GATE VALVE, G -3000, OR EQUIVALENT -c STREET ELS. CORP STOP INLET IRON PIPE THREAD OUTLET FOR STREET EL CONNECTION, EQUAL TO MUELLER #H9969, OR EQUIVALENT MAIN LINE + SERVICE SADDLE WITH SST BAND TAP SIZE AS REQUIRED ROMAC MODEL #2002S, OR EQUIVALENT STANDARD CONCRETE METER BOX 3 BACK OF CURB 2" GALVANIZED CAP BLOCKING 2" GALVANIZED PIPE TO FIT.— 2" 90' ELBOW --/ 1/2 C.Y. GRAVEL - BACKFILL FOR DRAIN. COVER GRAVEL WITH 15# FELT ROOFING MATERIAL. 3 2" BL0WOFF2 SCHEMATIC ONLY — NO SCALE THIS PROJECT IS LOCATED IN SECTION 2, TOWNSHIP 30 NORTH, RANGE 1 WEST, W. M., IN THE CITY OF PORT 70WNSFND_ ON THE UNREDUCED DRAWING THIS RECTANGLE IS ONE INCH SQUARE 01/30/S03 /YESBERGER /WATER2.DWG HORIZONTAL SCALE VERTICAL SCALE 12" MIN. WA RMAIN EXTENSION PREPARED FOR.- YESB'ERGER MUELLER CENTURY FIRE HYDRANT TWO 2 1/2" MAX 4", NST PORTS MIN 3 3" 7 CU. FT. MIN WASHED GRAVEL PASSING 1 -1 2" AND RETAINED ON 1 /4" MESH FOR DRAIN CONCRETE BLOCKING TO " "• "`x; BE PLACED AGAINST UNDISTURBED SOIL (TYP) TO BE PLACED " AGAINST UNDISTURBED SOIL (TYP) 16" X 8" X 4" MIN CONCRETE BLOCK MJ WITH RESTRAINT 3/4" ALL THREAD ROD- BLIND FLANGE 1 45' BEND 221 /2' BEND v 0A BLIND FLANGE NST STEAMER PORT 4" STORTZ ADAPTER 18" MIN, 28" MAX 90' BEND VALVE -BOX CAST IRON TEE, MEGA -LUG WITH 6" FLANGE SIDE OUTLET CONCRETE BLOCKING 6" GATE VALVE FL X MJ) 6" DUCTILE IRON PIPE CLASS 52 CEMENT LINED OR C -900 PVC LT PLI TEE BLIND FLANGE OR SMALLER SIZE PIPE L GATE VALVE 11 1/4' BEND CROSS THRUST BLOCK - TABLE MIN. BEARING AREA AGAINST UNDISTURBED SOIL SQUARE FEET 1 PIPE SIZE 0 FT2 Q FT2 FT2 a FT2 @ FT2 Q FT2, 4" 3 1 1 1 1 NONE 6" 4 4 2 1 1 NONE 8" 7 6 4 2 1 4 10" 11 10 6 3 2 6 12" 16 14 9 5 3 9 14" 22 19 12 6 3 12 16" 29 25 16 8 4 16 18" 36 31 20 10 5 20 20" 45 39 24 13 6 24 22" 54 47 29 15 8 29 24" 64 56 35 18 9 35 28" 87 76 48 24 12 48 30" 101 87 55 28 14 55 36 175 78 40 20 78 42" 197 125 71 107 55 27 107 48" 257 23 140 71 36 140 NOTES: 1. BEARING AREA OF CONCRETE THRUST - BLOCK BASED ON 200 PSI PRESSURE AND SAFE SOIL- BEARING LOAD OF 2,000 POUNDS PER SQUARE FOOT. 2. AREAS MUST BE ADJUSTED FOR OTHER PIPE SIZES, PRESSURES, AND SOIL CONDITIONS. 3. CONCRETE BLOCKING (CLASS 3000) SHALL BE CAST IN PLACE AND HAVE A MINIMUM OF 1/4 SQUARE FOOT BEARING AGAINST THE FITTING. 4. BLOCK SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING OF JOINT. 5. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL TEST PRESSURE UNDER ALL CONDITIONS OF SERVICE. 6. MINIMUM ROD DIAMETER SHALL BE 3/4" ASTM A -307 WITH 36KS1 YIELD STRENGTH. 5 THRUST BLOCKING2 SCHEMATIC ONLY — NO SCALE SEE N01E 2 GUARD POST O BREAK Al FLANGE I GUARD POST 18" rte SEE NOTE 1 low ELEVATION PLAN FIRE HYDRANT GUARD POST SEE NOTES 1 AND 2) 4 FIRE HYDRANT2 SCHEMATIC ONLY — NO SCALE PVC WATER MA /NS SHALL BE AWWA C900, PIPE BEDDING FOR PVC WATER CL 150 WITH SAME OUTSIDE DIMENSIONS AS MAINS SHALL BE CLEAN SAND /GRAVEL, r DUCT /LE IRON PIPE. JOINTS SHALL BE RUBBER FREE FROM ORGANIC MATERIAL AND RING & THICKENED BELL. SOLVENT WELD MEETING THE FOLLOWING GRADATION: GLUED) JOINTS SHALL NOT BE USED. JOINTS SH,4LL CONFORM TO ASTM D 3139 USING A SIEVE 9 PASSING RESTRAINED RUBBER GASKET CONFORMING TO SIZE (BY WEIGHT) ASTM F447. PIPE SHALL BE INSTALLED, TESTED, DISINFECTED AND OTHERWISE COMPLY WITH THE REQUIREMENTS OF SECTION 7 -11 OF THE WSDOT 314" 100STANDARDSPECIFICATIONS. PIPE FITTINGS AND 318" 70 — 100VALVESSHALLCOMPLYWITHSECTIONS9- 30.2(5) ,#4 55 — 100AND9 -30.3 RESPECTIVELY, OF THE WSDOT STANDARD SPECIFICATIONS. VALVES SHALL BE #10 35 — 95 INSTALLED PER SECTION 7 -12. "EARS" ON VALVE #20 20 — 80 BOXES SHALL BE ALIGNED WITH THE AXIS OF THE #40 10 — 55 PIPE. ALL VALVES SHALL HAVE RESILIENT SEATS. #100 0 — 10 200 0 — 3 TRENCH BACKF /LL TO BE SELECT NATIVE MATERIAL IN NON TRAFFIC AREAS AND CLEAN PIT RUN GRAVEL IN TRENCH WALLS MAY BE SLOPED TRAFFIC AREAS, TRENCH BACKF/LL TO BE MOUNDED BACK ABOVE ELEV OF PIPE 2" IN NON TRAFFIC AREAS TO ALLOW FOR SETTLEMENT. BEDDING (BOTH SIDES) PLACE 10 GA (MIN) INSULATED, \ TRENCH WALLS SHALL SOLID CORE COPPER LOCATE WIRE BE VERTICAL BELOW ALONGSIDE PIPE IN BOTTOM OF DITCH. ` THIS ELEVATION BRING WIRE UP INTO VALVE BOXES 1 11 AND LEAVE SMALL COIL. PLACE BLUE 3 LIFTS, EACH COMPACTED POLYETHYLENE MARKING TAPE WITH 6" TO 909 PRIOR TO PLACE — FOIL CORE DETECTABLE) IN TRENCH 12' — 18" BELOW + MENT OF SUBSEQUENT LIFT SURFACE OF GROUND. PIPE OD SINGLE 3" (MIN COMPACTED 30 " DEPTH) LIFT MAX) PIPE BEDDING FOR PVC WATER MAINS PER SPECS ABOVE, PLACED AS SHOWN PIPE INVERT TO BE 3.0' BELOW THE DESIGN ELEV OF THE CENTERLINE OF THE ADJOINING STREET OR 3.0' BELOW PROPOSED FINAL GROUND ELEV., WHICHEVER IS LOWER. PIPE BEDDING SHALL BE COMPACTED TO 909 OF MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D 1557 (MODIFIED PROCTOR). TRENCH BACKF/LL SHALL BE COMPACTED TO 959. WHERE MORE THAN 309 OF BACKF /LL MATERIAL IS RETAINED ON A 314" SIEVE, SUCH RETAINED MATERIAL SHALL BE DISCARDED AND THE PROCTOR TEST PERFORMED ON THE REMAINING MATERIAL. 6 PVC WATER MAIN TRENCH 2 SCHEMATIC ONLY — NO SCALE REVISIONS DETAIL NUMBER DETAIL REFERENCES CALL 48 HOURS BEFORE YOU DIG DATE DESCRIPTION 4 BALLOON REFERENCES TO DETAILS INCLUDE TWO NUMBERS. THE BOTTOM NUMBER IAITHE NUMBER 1 —8OO- 424 -5555OFTHEPAGEWHERETHEDETAILMBEFOUND. THE TOP NUMBER IS THE NUMBER OF THAT DETAIL. PACE NUMBER - FOR UNDERGROUND UTILITY LOCATE SERVICE CARSON PVC METER BOX MODEL ##1419, OR EQUIVALENT SHUT OFF WITH LOCK WING GROUND KEY 110 COMPRESSION MUELLER MODEL 825170, OR EQUIVALENT SERVICE PIPE - TYPE K COPPER CORP STOP INLET IRON PIPE THREAD OUTLET FOR 110 COMPRESSION CONNECTION, EQUAL TO MUELLER #H- 15028, OR EQUAL SERVICE SADDLE WITH SST BAND TAP SIZE AS REQUIRED ROMAC MODEL #101S, OR EQUIVALENT ICUSTOMER RESPONSIBILITY i i 6 "MIN PROPERTY LINE 2'MAX 3/4 FEMALE FLARE I J * STOUBEOUT CHECK VALVE BED WITH PEA GRAVE OR WASHED ROCK X TO PROVIDE POSITIVE / DRAIN OUT OF BOX *5E8%3 /4" METER NOTE: 1. A PRESSURE REDUCING VALVE INSIDE A SEPARATE METER BOX IS RECOMMENDED WHERE STATIC PRESSURE IS GREATER THAN 80 PSI. 2. PRESSURE REDUCING VALVES SHALL BE INSTALLED ON CUSTOMERS PROPERTY AT LEAST 3' FROM THE WATER METER BOX. 3. SIZE OF FITTINGS AND TAP SIZE SHALL BE AS REQUIRED FOR THE TYPE OF SERVICE. 4. * INDICATES ITEMS TO BE INSTALLED BY CITY. SINGLE SERVICE TAP2 SCHEMATIC ONLY — NO S(-AI F APPROVED NOT /CE: Plans are approved excepting any errors or omissions. All work must pass inspection in conformance with ab all app cab jeZod enlations Date Permit No By: CONSTRUCTION DETAILS tNlilRVE IN LAND SURVEYING WETLAND DELINEATION DEVELOPMENT CONSULTING rr SHEET 2 OF 2 P.O. Box 2199 935 N 5th Ave. Sequim, WA 98382 360) 681 -2161 NOTES: 1 GUARD POSTS SHALL BE 6' LONG, 8 "IN DIAMETER PRECAST CONCRETE OR 6' LONG, 6" DIAM SCH 40, CONCRETE FILLED CLASS 52 STEEL PIPE. PAINTED WITH TWO COATS OF "RUST— O —LEUM" NO. 2766, HI GLOSS YELLOW PAINT. 18" 2 TOP OF GUARD POST SHALL BE LEVEL WITH TOP OF FIRE HYDRANT OR 30" IF NOT ON LEVEL GROUND. s" 3 VALVE MARKER POST SHALL BE 42" PORTABLE TRAFFIC 42" I I DELINEATOR POST W /TWO REFLECTOR STRIPS. THEY SHALL BE FURNISHED NEW AND UNUSED AND BURIED 24" I I DEEP, TO LEAVE 18" EXPOSED AS A MARKER POST I I THE LETTER "V" AND THE DISTANCE TO THE VALVE I I SHALL BE STENCILED ON THE POST WITH 2" HIGH I NUMERALS, WITH BLACK ENAMEL PAINT. L J 4 VALVE MARKER POSTS SHALL BE INSTALLED FOR ALL VALVES LOCATED IN UNIMPROVED OR UNPAVED AREAS. VALVE MARKER POST VALVE MARKER POSTS SHALL BE SET IN A SAFE AND REASONABLY CONSPICUOUS LOCATION. SEE NOTES 3, 4 AND 5) 5 VALVE MARKER POSTS ARE NOT REQUIRED FOR AUXILIARY HYDRANT VALVES. PVC WATER MA /NS SHALL BE AWWA C900, PIPE BEDDING FOR PVC WATER CL 150 WITH SAME OUTSIDE DIMENSIONS AS MAINS SHALL BE CLEAN SAND /GRAVEL, r DUCT /LE IRON PIPE. JOINTS SHALL BE RUBBER FREE FROM ORGANIC MATERIAL AND RING & THICKENED BELL. SOLVENT WELD MEETING THE FOLLOWING GRADATION: GLUED) JOINTS SHALL NOT BE USED. JOINTS SH,4LL CONFORM TO ASTM D 3139 USING A SIEVE 9 PASSING RESTRAINED RUBBER GASKET CONFORMING TO SIZE (BY WEIGHT) ASTM F447. PIPE SHALL BE INSTALLED, TESTED, DISINFECTED AND OTHERWISE COMPLY WITH THE REQUIREMENTS OF SECTION 7 -11 OF THE WSDOT 314" 100STANDARDSPECIFICATIONS. PIPE FITTINGS AND 318" 70 — 100VALVESSHALLCOMPLYWITHSECTIONS9- 30.2(5) ,#4 55 — 100AND9 -30.3 RESPECTIVELY, OF THE WSDOT STANDARD SPECIFICATIONS. VALVES SHALL BE #10 35 — 95 INSTALLED PER SECTION 7 -12. "EARS" ON VALVE #20 20 — 80 BOXES SHALL BE ALIGNED WITH THE AXIS OF THE #40 10 — 55 PIPE. ALL VALVES SHALL HAVE RESILIENT SEATS. #100 0 — 10 200 0 — 3 TRENCH BACKF /LL TO BE SELECT NATIVE MATERIAL IN NON TRAFFIC AREAS AND CLEAN PIT RUN GRAVEL IN TRENCH WALLS MAY BE SLOPED TRAFFIC AREAS, TRENCH BACKF/LL TO BE MOUNDED BACK ABOVE ELEV OF PIPE 2" IN NON TRAFFIC AREAS TO ALLOW FOR SETTLEMENT. BEDDING (BOTH SIDES) PLACE 10 GA (MIN) INSULATED, \ TRENCH WALLS SHALL SOLID CORE COPPER LOCATE WIRE BE VERTICAL BELOW ALONGSIDE PIPE IN BOTTOM OF DITCH. ` THIS ELEVATION BRING WIRE UP INTO VALVE BOXES 1 11 AND LEAVE SMALL COIL. PLACE BLUE 3 LIFTS, EACH COMPACTED POLYETHYLENE MARKING TAPE WITH 6" TO 909 PRIOR TO PLACE — FOIL CORE DETECTABLE) IN TRENCH 12' — 18" BELOW + MENT OF SUBSEQUENT LIFT SURFACE OF GROUND. PIPE OD SINGLE 3" (MIN COMPACTED 30 " DEPTH) LIFT MAX) PIPE BEDDING FOR PVC WATER MAINS PER SPECS ABOVE, PLACED AS SHOWN PIPE INVERT TO BE 3.0' BELOW THE DESIGN ELEV OF THE CENTERLINE OF THE ADJOINING STREET OR 3.0' BELOW PROPOSED FINAL GROUND ELEV., WHICHEVER IS LOWER. PIPE BEDDING SHALL BE COMPACTED TO 909 OF MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D 1557 (MODIFIED PROCTOR). TRENCH BACKF/LL SHALL BE COMPACTED TO 959. WHERE MORE THAN 309 OF BACKF /LL MATERIAL IS RETAINED ON A 314" SIEVE, SUCH RETAINED MATERIAL SHALL BE DISCARDED AND THE PROCTOR TEST PERFORMED ON THE REMAINING MATERIAL. 6 PVC WATER MAIN TRENCH 2 SCHEMATIC ONLY — NO SCALE REVISIONS DETAIL NUMBER DETAIL REFERENCES CALL 48 HOURS BEFORE YOU DIG DATE DESCRIPTION 4 BALLOON REFERENCES TO DETAILS INCLUDE TWO NUMBERS. THE BOTTOM NUMBER IAITHE NUMBER 1 —8OO- 424 -5555OFTHEPAGEWHERETHEDETAILMBEFOUND. THE TOP NUMBER IS THE NUMBER OF THAT DETAIL. PACE NUMBER - FOR UNDERGROUND UTILITY LOCATE SERVICE CARSON PVC METER BOX MODEL ##1419, OR EQUIVALENT SHUT OFF WITH LOCK WING GROUND KEY 110 COMPRESSION MUELLER MODEL 825170, OR EQUIVALENT SERVICE PIPE - TYPE K COPPER CORP STOP INLET IRON PIPE THREAD OUTLET FOR 110 COMPRESSION CONNECTION, EQUAL TO MUELLER #H- 15028, OR EQUAL SERVICE SADDLE WITH SST BAND TAP SIZE AS REQUIRED ROMAC MODEL #101S, OR EQUIVALENT ICUSTOMER RESPONSIBILITY i i 6 "MIN PROPERTY LINE 2'MAX 3/4 FEMALE FLARE I J * STOUBEOUT CHECK VALVE BED WITH PEA GRAVE OR WASHED ROCK X TO PROVIDE POSITIVE / DRAIN OUT OF BOX *5E8%3 /4" METER NOTE: 1. A PRESSURE REDUCING VALVE INSIDE A SEPARATE METER BOX IS RECOMMENDED WHERE STATIC PRESSURE IS GREATER THAN 80 PSI. 2. PRESSURE REDUCING VALVES SHALL BE INSTALLED ON CUSTOMERS PROPERTY AT LEAST 3' FROM THE WATER METER BOX. 3. SIZE OF FITTINGS AND TAP SIZE SHALL BE AS REQUIRED FOR THE TYPE OF SERVICE. 4. * INDICATES ITEMS TO BE INSTALLED BY CITY. SINGLE SERVICE TAP2 SCHEMATIC ONLY — NO S(-AI F APPROVED NOT /CE: Plans are approved excepting any errors or omissions. All work must pass inspection in conformance with ab all app cab jeZod enlations Date Permit No By: CONSTRUCTION DETAILS tNlilRVE IN LAND SURVEYING WETLAND DELINEATION DEVELOPMENT CONSULTING rr SHEET 2 OF 2 P.O. Box 2199 935 N 5th Ave. Sequim, WA 98382 360) 681 -2161