Loading...
HomeMy WebLinkAbout9205-04Watuman ~ KalzHudding I81 Quincy St[tet, Suite 301 Port2owmenQ WA 98368 Phone: (360)379-3206 Fu: (360)379-6923 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD92O5-04 R-) Issued: lOt . 99 Parcel Number: 948303105 Job Address: 1071 Landes Ct. Zoning :R=II Type: V/NR Occupancy: R-3/U-1 Total Occupant Load: <10 Nature of Work: Revise deck and covered porch. Owner: Callahan, Earnev Contractor: Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: REQUIRED INSPECTIONS APPROVED/DATE • Footings 1'6" X 10" square poured concrete- w/ 2 # 2 re- steel EW. Framing Double 2"X12" @ the S.E. corner Truss to rafter connection w/ 5/8" bolt Final House Numbers Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Pmnit q BLD4305-04R-1 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection ofadjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection. report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A 7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for anon- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within-one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates • I-800-424-5555 Page 2 of 2 ~ C S T Y O F PORT T O WN S EN D BUILDER'S PERMIT & INSPECTION RECORD (See Instructions on Attached Sheet) THIS CARD MUST BE POSTED AT CONSTRUCTION SITE CALL 385-2294 FOR INSPECTION Permit Humber Callahan. Ernie Issued 5/6/92 Treas. No. Jab Address 1071 Landes Court Zoning R-1 Type 5-N Occupancl R-3 Nature of Work R~~ i 1 ~I paw hnme Dse of Buiidinq(sj Dwel 1 i na o'me7 Farn ACt Callahan, 7r. Contractor Same a s Owner *NEW ENERG'1 CODE* 1. GROUNDWORK: Plumbing Inspector Date 2. FOOTINGS/SL.ABS: Setbacts ~~ Forms ~" Reinforcement L~ Slab_ Inspector~- 1•[~`'t.--' Date ~ -~ - ~'~ r,;~Cl i` 3. FOONDATION MALL: Forayer Reinforcement- Weather Praafinq~~ ~- Yents_ Cravl Acess_ Insnect~ ~. ~' Date "' , ~ ~( c 4. fI00R FBANING:. Girders- Joists- Bridging Shield Under Posts- Positive PostJGirder Connect Girder/Concrete-1/2"_ Treated Wood to Concrete- anchor Bolts v/Washers- Inspector Date 5. PLDlR3IHG: Drains- Yents_ Traps- Clean-outs ' Water Supply- Gas Supply-+;F__ ' ' : ,' , n i v(: ~ j Inspector `- , Date ~ ~ -• r ~, ,~, 4" '6. NECBAffiCAL: Furnace- Erhaust_ Heat Ducts- Inspector Date i. FBANING: Walls- Ceiling ~ Roof Veers ~ Windovs_ C.,. In Wall Pepetrations_ Chimmey Straps- Inspector J~. ~ Date ~ ' `" F._ % ,/. a. INSDLATION: Floor ' Wall _' Ceiling` Baffles 4. Inspector I ^ ~~ Date ~ ^ ~ !' 9. DRYWALL HAILING: Walls- Ceiling- Inspector Date r ,. ~;iik l , ~ `~ , ~~ .~:, ~~~ ' ~~g/~ ~ / Inspector /S 10. DRAINAGE: Required; attached ~ Date3 i 19~ FINAL INSPECTION: Buildinq_/ Plumb. Nech/heating Smoke Det. L~~ House No. v ****FIRE HYDRANT AT 10th AND HILL STREETS****Inspector ~ i Date e ~ ~ ~r C a 1 1 4 8 hours before you d i g ~E'o r utility line locate s 1- 8 0 0- 4 Z 4- 5 5 5 5