Loading...
HomeMy WebLinkAboutBLD02-282 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDQZ-282R-2 Issued: 06/06/03 Parcel Number: 948 308 201 Job Address: 1625 17th Street Zoning: RR=II Type: VV=N Occupancy: RR=3 Total Occupant Load: N/C Nature of Work: Revision #2• en2ineerine for braced wall aanel at second story bedroom #3 Owners: Aliva & Michael Scanlon Contractor: Vernon Garrison - VERNOGC06208 GENERAL CONDITIONS APPLY: See last aaee SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 NOTE: For all other inspections, refer to original permit BLD02-282 RE UIRED INSPECTIONS APPROVED/DATE FRAMING -per engineerrrrg 0~ ~~03 Building Permit. #02-282R-2 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of .this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. TheBuilding Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year, Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. CITY OF PORT TOWNSEND • CONSTRUCTION PERNIIT & INSPECTION RECORD THTS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD02-282R-1 Issued: 02/10/03 Parcel Number: 948 308 201 Job Address: 162517th Street Zoning: RR=II Type: VV=N Occupancy: R;3 Total Occupant Load: N/C Nature of Work: Revision #1: Increase retaining wall height to 9 feet. Owners: Aliya & Michael Scanlon Contractor: Vernon Garrison - VERNOGC06208 GENERAL CONDITIONS APPLY: See last page SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 RF.fITITRF.n TNSPF.CTTONS APPROVED/DATE FOOTINGS -per attached engineering Setbacks Footings Forms Reinforcement FOUNDATION - ald elements of engineering require inspection prior to cover a Stem Wall ~~:: ~ ,~}~ ~ c°'~ ~ ~ Forms ~~~ ~~ ~ ~~~` ~ ~ Reinforcement • Building Pmnil p02-2g2R-I GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies Doted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works aoaroval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval arior to making changes in the field. CoataM the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Watumm & KMZBuilding 181 Qumry S4ee[, Suite 301 Port Toumund, WA 98368 Phone: (360)379.37A8 Fsx: (360)385.7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION STTE Call 385-2294 for Inspection Permit Number: BLDO2-282 Issued: 02/04/03 Parcel Number: 948308201 Job Address: 1625 17th Street Zoning: RR=II Type: VV=N Total Occupant Load: 4 Occupancy: R-3 Nature of Work: Construct Sinele family residence Owner: Alive &: Michael Scanlon Contractor: Vernon Garrison VERNOGC06208 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 Street and Utility Development Permit n ~J REQUIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See General Condition No. 2 & attached erosion control details Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site GROUNDWORK PLUMBING Pressure Test Pipe Joints Exposed Pipe Bedding Trap Seal Protection for floor drains (if applicable) FOOTINGS Setbacks ~ ~~ 7~ (~S ~u SS.~y~ y'~-• GL- Footings Fyn. ~~ ~,,~,'(~~~ Forms Reinforcement UFER Porch/Deck Pier Footings • Ca11 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 ranmxBtnm-zsz' REQUIRED INSPECTIONS APPRnVF.>7/nATF. FOUNDATION Stem Wall Forms Reinforcement Anchor Bolts & Washers ABWP Holdoxms Beam Pockets Waterproofing SLAB Interior Footings Reinforcement O ~ r• Zi-a3 , PLUMBING: Rough-In (D-V-T & Clean outs). Gas Supply , Water Supply Water Hammer Arrestor (a~ clothes and dishwasher Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi Water Heater/Boiler R-10under Seismic Restraint Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL LPG Fireplace Boiler -installation instructions shall be on-site at time of inspection Whole House Fan - @ utility room Source Specific Fans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) FRAMING Walls -see notes on,~loor plan, F-2, for possible lateral engineering l ' F~~ ~~G ~•- O}~ ~~a3 ~ F oor Beams Floor joists -Engineered I joist plan to be on-site at time of inspection ~~~~_'~ ""~~~ ~_ tr(~~c~ Hydronic Tubing Blocking Treated Wood to Concrete Positive Connections Anchor Bolts & Washers ~~ Ca1148 hours before you dig for utility line locates 1-800.424-5555 Psge 2 of 4 RFf)TiTRF,>) TNSPF.('TTnNS Permit#BLD02-282 APPROVED/DATE FRAMING (continued) Ceiling/Roof -engineered truss plan to be o»-site at time of 'nspection cuss Positive Connection Blocking Roof Venting - @ eave & ridge Skylights Windows -escape Windows U-factor - .40 or better NFRC window sticker must be on windows, skylights and doors Air Seal Fresh Air Intake (Window or Wall Ports required) Doors U-factor - .20 or better Fire Blocking Weather Resistive Barrier INSULATION Floor (R_30) ______..-__-- Walls - R-21) ~ ~Z jD3 ~'K Ceiling - R- - -______. -- -_ _ ._ _ Baffles _ Vapor Barrier: paint DRY WALL NAILING Walls eiling ©l~~ ~~f`l~a~ v Enclosed Usable Space under Stairs (if applicable) FINAL Public Works Sign-Off LPG " a ~ ~ ~~~~~;~~ ti ,~~. `~~ ~ ' ~ - minimum House Numbers - 5 ~ Plumbing ___ Mechanical/Heating Insulation Certificate Vapor Barrier Paint Certificate Smoke Detectors Final -Building 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Permit#BLDOS•382 ~~ 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 3852294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. So~7s shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and. all defiaencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits ezpire if no progress has been made within sia months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800.424-5555 Page 4 of 4