HomeMy WebLinkAboutBLD02-274 CITY OF PORT TOWIVSEND Watttman &KalzHuilding 181 Qumry SbeH, SuiOe 301 Port Towmend, WA 98368 Phone:(3ao~379-3zos Pax:(36o~assabn CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION STTE Ca11 3 85-22 94 for Inspection Permit Number: BLDOZ-274 Issued: 01/13/03 Parcel Number: 958 900 002 Job Address: 4967 Mason Street Zoning: R-I Type: V_N Occupancy: R-3/U-1 Total Occupant Load: ti/2 Nature of Work: Construct single-family residence with attached ¢araee Owners: Jack and Marsha Hensel dba Hensel Investments Contractor: Seven Bridees Prouerty. LLC - SEVENBP983JD GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMTTS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 • ~: Outside construction activities shall be limited to Monday through Friday 7:00 a.m. to 6:00 p.m. and prohibited on weekends and national holidays REQUIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2&MIP03-004 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks ~ Footings 0 G . ~~ Forms ~~, o ~ _~ ~ Reinforcemen ~_~_,. Interior Footings ~ -~ _ Porch/Deck Piers-~---~" ~- _ ~ ~- UFER ~~ ~ ~ ~L~ (j ~ ' ~~_ (>~ Call 48 hours before you dig for utility line locates I-800-424-5555 Page 1 of 5 PamitBBLD02-]74~ ~ REQUIRED INSPECTIONS APPRnVF,nmATF. FOUNDATION Stem Wall Forms ~ / ~ ( , , Reinforcement ~, / Anchor Bolts & BP washers Vents -14 required ,,1 ~' Crawl Access [ d' Alternate Braced Wall Panel Holdowns FLOOR FRAMING ~ Joists -engineered BCI plan shall be on-site at time of ~, S Inspection l ~ ~ 0 Beams Blocking 2i 1 ~ _~p~ Positive Connections ~ /" V Treated Wood to Concrete Beam Pockets PLUMBING: Rough-In (D-V-T & Clean outs) Water Supply up a e ammer es er cot es ~s w Hose Bibs (backflow protection required) Pipe Insulation (R 3) _ l Pressure Reduction Valve if > 80 psi ~ ~ij(, Water Heater 1 _/ R-10 under ¢ ~ /L~/ Seismic Restraint -strap tank @ 113 points 18" A. F. F. Pressure relief valve drain to exterior, terminate 6" - 24" above ground • Call 48 hours before you dig for utility line locates 1-800.424-5555 Page 2 of 5 P~;~ s Blum-a~a RFfITTTRF.TI TNCPF.f'TTnNS APPROVEB/DATE • I~ MECHANICAL-- -- -- - - - - - - ~ ~+ ~°u D f ~ P~ t a z o Electric Heat Pump Manufacturer's installation instructions to be on-site @ time of inspection. Ducts & Duct Insulation -Supply/fresh air ducts in conditioned space: R-4; heating ducts in unconditioned space: R-8 Whole House Ventilation -P~/ "~ t~ 1 Z$ 6 3 HVAC Integrated Fresh Air ~D~ T' Smooth Duct minimum Terminal Element - 8" Clock timer on furnace fan Other than motorized damper requires letter of certification for flow rates. LPG Fireplace -provide specs on-site Source Specific Fans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) FRAMING Walls Cei mg oor -engineered BCI plans to be on site O I~ ~4 Ire 30 oof-Engineered truss lan to be on site at inspection Blocking Truss & Rafter Positive Connections ~ Roof Venting - eave and ridge vents Windows -escape ,oJ~-J ' Windows -safety glazing Windows Ufactor - .40 or better for unlimited glazing F~ / D f I a3 ~ NFRC window sticker must be on windows & ~ I Z~ doors at inspection time Fresh Air Intake - HVAC Integrated option Doors U-Factor - .20 or better/Rated doors @ garage/house Air Seal Fire Blocking Weather Resistive Barrier INS TION o - alls (R-21) Ceiling (R-38) Vapor Bamer: paint ~_,y..~ y, ._(.,(~ , ~ '~D L D l ' Baffles 1/~' ~ 6 mil black poly • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of S REQUIRED INSPECTIONS Pawn s shat-na APPROVED/DATE DRY WALL NAILING '1 ~~_ Interior braced wall panels (~~ ~N y ~ lt- Walls Ceiling Garagelfiouse Occupancy Separation ]J n~ /_ r(~ l7' ~I (~lti~ Enclosed Usable Space under Stairs FINAL Public Works Sign-Off LPG House Numbers - 5" minimum Plumbing Mechanical/Iieating Vapor Barrier Paint Certificate Insulation Certificate Fresh Air Certification for Integrated System Smoke Detectors Final -Building GENERAL CONDITIONS 1. Contractors' Working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils eaposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc, once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report correMions are completed 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected For Public Works inspection ca11385-2294. A 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. Call 48 hours before you dig for utility line locates 1-800.424-5555 Page 4 of 5 _ rye s aiom•r~a 8. All building permits ezpire if no progress has been made within sia months, or if no inspections are done by the Building Department within ane year. Call for st least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Call 48 hours before you dig Tor utility lice locates 1-800-424-5555 Page 5 of S 4 •