CITY OF PORT TOWNSEND
~ CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
CaU 385-2294 for Inspection
Permit Number: BLDO2-241R-1 Issued: 12/05/02 Parcel Number: 972 600122
Job Address: 3162 McClellan Zoning: RR=II Type: VV=N Occupancy:
Nature of Work: Construct 400 sa. ft. detached Garaee. and 60 sa. ft. site-built uorch. See BLD02-241 for
manufactured home.
Owner: Richard Tracv Contractor: Owner
GENERAL CONDTTIONS APPLY -SEE LAST PAGE
RE UIRED INSPECTIONS
APPROVED/DATE
TEMPORARY EROSION & SEDIMENT CONTROL
See General Condition No 2
SLAB/CONCRETE
Setbacks
Forms
Monolithic Slab/Foundation (gazage)
Reinforcement
Anchor Bolts
Porch Piers
Alternate Braced Wall Panel Holdown Hazdwaze
UFER
FRAMING
Engineered truss plan to be on-site at time of inspection
Walls
Treated Wood to Concrete
Ceiling/Roof
Windows
Attic Venting
Blocldng
Truss Positive Connection
Fireblocldng
Weather Resistive Barrier
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit#BLD07.7AYR-f
.~
REQUIRED INSPEC_'TinN~
DRYWALL/NAILING (:f applicable)
Walls
Ceiling
FINAL
Final -Building, see BLD02-241
e prR nvFnm a T>~
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
num r and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measwes shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measwes shall include installation of silt fencing and graveled
construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils exposed during
construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is compkke. Applicant is
responsible for protection of adjacent properties.
3. AR elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report correMions are completed.
6. The Building Department is unable to pass final inspection on yow project until Public Works
requirements have been completed and inspected For Public Works inspection call 385-2294. A
7. Final Inspections are required prior to octupaoty. A Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits expire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at k;ast one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Wolerman & Kate BWIMng
' 161 QWncy Scree; SWla 301
Port Toxceeod,WA 98368
~ Fhoce: 3603793208 Fez3603B6-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO2-241 Issued: 10/15/02 Parcel Number: 972 600122
Job Address: 3162 McClellan Street Zoning: RR=II Type: V_N Occupancy: RR=3
Total Occupant Load: 4 Nature of Work: Set new manufactured home: add landine.
Garace and porch to be deferred submittal.
Owner: Richard Tract/ Contractor: Owner -See General Conditon ill
****Installer: See Attached Installer Tae****
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
NOTE: Set-up manual shall be on-site at time of inspection.
RE UIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See general condition #2
Silt Fence as needed
Drive Off Mat to prevent sediment from leaving
the she
~'
~ ~ ~ ~--
~~ ~~ `b ~ ~
~ b ~
FOOTINGS/SLAB
Setbacks
~~l-
Forms
Reinforcement C7 0 -L.
. ~ ~i
' ~
Footings -minimum 4" per installation manual. ~
'w l
FLOOR FRADIING (prior to skirting) ~
b
'
Anchors `
Steel Support Piers -Load-stamped and installed ~
per mamrfacturer's installation mamral; clearance ~ ~~
~
of I8"min. from lowest point of I-beam and the
ground or footing for min. of 75% of area under
ll
/ 12"
h
l
i
ti
h
l Z
j
~
ome w
min. e
sew
ere un
ess
nsta
a
on ~
l 1 ~~ ~
\
marmad species; otherwise area around home
ailed to rovide runo aw om home.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Permit ilBLD07-241 ~~
REQUIRED INSPECTIONS APPROVF.TI/DATF,
~~'°~~~
6 k~e~
PLUMBING:
Water Supply -Main shut-off valve (port or ball valve)
installed in water supply piping prior to connection to 1 ))
`
home, min. '/s "diameter, same as supply pipe ~_ I4~
Pressure Reduction Valve if> 80 psi
Hose Bibs (backElow protection required)
Pipe Insulation -Outside & in crawl space
Pressure Test -100 p.s.i. for IS minutes
Pressure relief valve drain - to exterior of skirting,
"
" ~;~
C ~ ~ ~ ..
exhaust dawmvard between 6
and 24
above ground
Drainage Piping -sloped min. %s' per foot
MECHANICAL
~ -
Ducts & Duct Insulation ~
' ~
Dryer Exhaust -vented to outside. Extension into crawl ~ f~ ~-d
space requires venting through skirting with no dips;
follow dryer manufacturer's instructions; total combined
length of ducting not to exceed 14' w/ 2-90° elbows ~~
FRAIIHNG:
Landing, Handrails (if applicable)
Pressure-treated or of natural resistance to decay.
VAPOR BARRIER ,/
6 mil black poly ground cover (not required where area v,ts-
under home is concrete slab floor with a minimum
~
thickness of 3 % inches) ~
j .
nv
FINAL
Public Works Sign-Off
Electrical (L & I) Sign-Off
House Number -minimum 5" numbers
Plumbing ///~~~,,,
Mechanical
Final - Buildin
g ~~~~~~~ 3
No holes or gaps greater than'/s"allowed in skirting.
Crawl space ventilation per installation manual Q,
I/150 (13 required), located close to corners, on at least
two opposing sides for cross ventilation.
Crawl space access must provide access to all areas
under home, minimum 18" x 24 ", covered with virryl,
pressure treated wood or metal.
Call 48 hours before yon dig for ah7ity line locates
I-800-424-5555
Page 2 of 3
+a _ , . - ~~- - _
•.
PernJt pBLDb2-241
I GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to proride proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing snd
graveled construction entrance (see attached details). Soils ezposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed
6. The Building Department is unable to pass final inspection on your projeM until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress bas been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
CaD 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
~•