Loading...
HomeMy WebLinkAboutBLD02-237Waterman &. Katie Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360)379-3208 Fax: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Namber: BLDO2-2378-1 Issued: 10/29/03 Parcel Number: 999 300 001 Job Address: 1590 49"' Street Zoning: R-I Type: VV=N Total Occupant Load: No Chance Occupancy: R-3/U-1 Natuee of Work: Revision #1: remove mechanical room. revise window sizes. relocate porch colamns, and realace some rafters with trusses. Owner: Sylvia Platt/ Bernie Donanbere Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See original permit BLD02-237 for other inspections. RE UIRED INSPECTIONS APPROVED/DATE FOOTINGS -See original Permit Record Porch/Deck Piers L~ r FRAMING -See also original Permit Record Trusses -Engineered truss plan to be on site at (. inspection Truss positive connection 2x8 DF#1 Rafters ,' Rafter positive connection ? ' INSULATION- See also original Permit Record High Density Insulation required at 2x8 Rafters FINAL- See original Permit Record Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Pest # BISJ02437R-1 Ai. ONDITION 1. ContraMors working on this project are required to have a Labor & Industries contractor's re¢istration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11 3 8 5-22 94. Measures shall indnde installation of silt fencing and graveled construction'entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deTciencies noted by required inspections. 5. Re-inspection is required after inspection report correMions are completed. 6. The Building Department is unable to pass dual inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection cal! 385-2294. A 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon- residentialproject. 8. All building permits expire if no progress has. been made within sia months, or if no inspections are done by the Bullding Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions .require submittal and approval rior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMTT ON-STTE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 Waterman & KYZ Building 1 el Quinry Slrxt, Suite 301 Port Towmend, WA 98368 Phom:(360)379-3208 Fax: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOZ-237 Issued: 12/02/02 Parcel Number: 999 300 001 Job Address: 1590 49'° Street Zoning: R-I Type: VV=N Total Occupant Load: 8 Occupancy: R-3/U-1 Nature of Work: Construct Single family residence Owner; Svlvia & Joan Platt Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 REQUIRED INSPECTIONS APPRnVF,T)/1)ATF. TEMP EROSION & SDM'T CONTROL See General Condition No. 2 & attached SDP 02-019 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks ,7 Footings ~// ~ C% Forms Reinforcement Interior Footings Porch/Deck Piers UFER FOUNDATION Stem Wall ` ~~ ~3 Forms 1 1 Reinforcement Anchor Bolts & Washers Vents -13 required V ~ Crawl Access ' Engineered Holdowns Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 Permit MBLLNI3.277 REQUIRED INSPECTIONS APPRnVF.D/DATF. FLOOR FRAMING Girders Hydronic Heat Tubing Joists - BCI plan to be on-site at time of inspection Blocking Shield under Posts Positive Connections Girder to Concrete Beam Pockets Treated Wood to Concrete f ~ZG a ~63 P QS s-e~'. per- c, ~ ~ ~ ~`'~(' ~' PLUMBING: Rough-In (D-V-T & Clea s uppt 5~L ~K - ~ - L7- ~ ~ 3 ater upp y Water Hammer Arrestor @ clothes and dishwasher Hose Bibs (backflow protection required) Pipe Insulation (R-3) ~ Pressure Reduction Valve if> 80 psi ' ~ Water Heater/Boiler Seismic Restraint - 2 places Pressure relief valve drain to exterior, terminate 6" - 24" above ground / ~-~ / t , MECHANICAL Boiler -installation instructions shall be on-site at time of inspection Whole House Fan - @ utility Source Specific Fans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from op ings) _ t~ 1 ply ~~ ~~T~`~ v Ca1148 hours before you dig for utility line locates 1-800-424-5555 Psge 2 of 4 Ymnit # BLDM-Yi7 REQUIRED INSPECTIONS APPROVED/DATE FRAI~IING alts p - ~~~ ~ ~ ~ ' ~ ~ ~ ` ~ ~ Engineered Shear Walls 1 ~ ~ Engineered Readers & Beams Treated Wood to Concrete Ceiling/Roof Rafters Rafter Positive Connection t Roof Venting - @ eaves , ! ~7 Windows-escape - jLl~ ~'J.- Windows U-factor - .40 or better l _ r , ~ ~' !!! _ NFRC window sticker must be on windows r i ~ ~ ~ ,' ,,~ ~ and doors at inspection time ~ ; ~, ' ~~ ' j /~ Door U-factor - .20 or better -y' ~ "' ~ Air Seal , ~ - -- _ ~ ~ '` -- resh Air Intake (Wall Ports) ~ -- - `" ~ Weather Resistive Bartier INSULATION loor (R30 ) alts - (R=21 ) Ceiling - (R=30 ) Baffles Vapor Barrier: paint 6 mil black poly in crawl space DRY WALL NAILING Walls Ceiling Engineered Interior Braced Wall Panels Enclosed Usable Space under Stairs Call 48 hours before you dig for utility line locates I-800-424-5555 Page 3 of 4 Permit%BLDOI.2i7 Public Works Sign-Off LPG House Numbers - 5"minimum Plumbing Mechanical/Heating Insulation Certificate Vapor Barrier Paint Certiftcate Smoke Detectors Final -Building ~~ g X5,07 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shaft be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels. (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your projeM until Public Works requirements have been completed and inspected For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required. Public Works aouroval must be received urior to scheduling the Buildine Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora oon- residentisl project. 8. All building permits expire if no progress has been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval grior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates • 1-800-424-5555 Page 4 of 4