HomeMy WebLinkAboutBLD02-227Waterman & Kats Huildmg 1 el Q~r Street, Suite 301 PatTamseod WA 93366 Pluxe: (360) 379-3?AB Fax: (360) 3796913 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOZ-227R-1 Issued: 10/11/02 Parcel Number: 999100104 Job Address: 2180 Victoria Avenue Zoning: R_II Type: V_N Occupancy: U-1 Nature of Work: Construct 720 sa. ft. detached Garase. See BLD02-227 for manufactured home. Owner: Pete Foa Contractor: Consolidated Builders. Pat Richardson WAINS#0851- CONSOI*993LI GENERAL CONDITIONS APPLY -SEE LAST PAGE RF.nTTTRFT) TN~PF.C'.TIONS APPROVED/DATE TEMPORARY EROSION & SEDIMENT CONTROL See General Condition No 2 FOOTING Setbacks Footings Forms Reinforcement LIFER FOUNDATION Stem Wall ~,/ ~/ ~~i B ~~~ ~< l~~ Forms Reinforcement Anchor bolts w 2"x 2" x 3/16" washers FRAIIIIING Engineered truss plan to be on-site at time of inspection , ~ Walls ~ ~0~ Treated Wood to Concrete Ceiling/Roof Windows Attic Venting Blocking Truss Positive Connection Fireblocking Weather Resistive Barrier Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Pgmit#BLDayZ27R l REOUIItED INSPECTIONS APPROVED/DATE DRYWALL/NAILING (if applicable) Watts Ceiling FINAL Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration number and a City business license. Failure to provide proof of this documentation prior to work may resuk in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance. Adjacent rights-of-way shall be kept free of dirt c$ debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanentiy stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required alter inspection report corrections are completed. 6. The Bm7ding Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A 7. Final Inspections are required prior to occupancy. A Certificate of Occupancy is required for a noa residential projeM. ' 8. All buildmg permits aspire if no progress has been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. ContaM the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. C~ Call 48 hours before yon dig for utility line locates 1-800-424-5555 Page 2 of 2 w.ta.m.o s rcm swim 181 QWoey SOSe4 suae 301 PaA Toworcnd. WA 98368 P6Na 3603795308 F~3603&5-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOZ-227 Issued:lO/ll/02 Parcel Number: 999100104 Job Address: 2180 Victoria Avenue Zoning: RR=II Type: VV=N Occupancy: RR=3 Total Occupant Load: 5 Nature of Work: Set new manufactured home: add deck. See BLD02-227R-1 for detached site-built earaae. Owner: Pete Foa Contractor: Consolidated Builders. Pat Richardson WAINS#0851 ****Installer: See Attached Installer Tag**** C~ • GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMTTS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: Set-up manual shall be on-site at time of inspection. REOiTiRED INSPECTIONS APPROVED/DATE TEMP EROSION & SEDIMENT CONTROL See general condition #2 Silt Fence as needed Drive OffMat to prevent sediment from leaving the site FOOTINGS/SLAB Setbacks Forms Reinforcement Footings -minimum 4" per installation manual. FLOOR FRAMING (prior to skirting) Anchors Steel Support Piers -Load-stamped and installed per mamrfacturer's installation manual; clearance of I8"min. from lowest point of I-beam and the ground or footing for min. of 75% of area under home w/ 12 "min. elsewhere unless installation manual species; otherwise area around home ceded to rovide runo aw om home. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 PeeailtlEBLD03-237 ~ REQUIRED INSPECTIONS APPROVF,11mA'f F. PLUMBING: - -- ----- Water Supply -Main shut-o,,~'valve (port or ball valve) installed in water supply piping prior to cotmection to home, min. '/."diameter, same as supply pipe Pressure Reduction Valve if> 80 psi Hose Bibs (bacldlow protection required) Pipe Insulation -Outside & in crawl space Pressure Test -100 p.s.i. for IS minutes Pressure relief valve drain - to exterior of skirting, exhaust dawmvard between 6"and 24"above ground Drainage Piping -sloped min. '/. "per foot MECHANICAL Ducts & Duct Lnsulation Dryer Exhaust -vented to outside. Extension tmo crawl space requires venting through skirting with no dips; follow dryer manufacturer's instructions; total combined length of ducting not to exceed 14' w/ 2-90° elbows FRAMING: Wood Deck Entry Stairs, Landing, Handrails Pressure-treated or of natural resistance to decay. VAPOR BARRIER 6 mil black poly ground cover (not required where area under home is concrete slab floor with a minimum thickness of 3-% inches) FINAL Public Works Sign-Off Electrical (L & n Sign-Off House Number -minimum 5" numbers Plumbing Mechanical Final -Building No holes or gaps greater than !/."allowed in skirting. Crawl space ventilation per installation manual @ 1/ISO (IS required), located close to corners, on at least two opposing sides for cross vemilation. Crawl space access must provide access to all areas under home, minimum 18" z 24 ", covered with vinyl, pressure treated wood or metal. ~~ Call 48 hours before you dig for utility liue locate I-800-424-SSSS Page 2 of 3 Permit MBLD02-227 J GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a Ciri business license. Failure to provide proof of this documentation prior to work may result in job shut down white this is accomplished. 2. Temporary erosion and sediment coirtrol (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencipg and graveled construction entrance (see attached details). Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. AU elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your projeM until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Departments final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. Ali building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department ak 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 ;~