Permit Number: BLDOZ-221 Issued: 09/19/02 Parcel Number: 989 713 403
Job Address: 614 Fillmore Street Zoning: R-III Type: VV=N Occupancy: S=3
Nature of Work: Remove cedar roofin¢, reulace anv dama¢ed sheathin¢, install underlavment and
metal panels. and provide adequate ventilation.
Owner: Rov Parkinson -Fillmore Street Garage Contractor: Olvmuic Steel
(385-3353)
NOT. • Repair/replacement of roof structural members (e.g., roof rafters, joists,
truss system, etc.) requires revision to this permit
GENERAL CONDITIONS APPLY -SEE LAST PAGE
REOUiRED INSPECTIONS
APPROVED/DATE
DEMOLITION
All construction debris to be deposited in Jefferson
County Landfill or other location in accordance with
all local, state and federal laws.
SHEATHING
Nailing requires 8d @ 6" o.c. edges & 12" o.c. field or
1 3/a" staples @ 6" o.c. edges and field.
ROOF VENTING
Ridge Vents
Net free ventilation area shall not be less than 1 square
foot per 150 square feet of the area of the space
ventilated, unless 50% of the required vent opening
area is provided in the upper portion of the roof and
therefore the rate maybe reduced to 1 squaze foot of
venting to 300 square feet of area vented. Openings
shall be covered with corrosion resistant''/e" mesh.
ROOFING
All materials shalt be installed per the manufacturer's
installation instructions and UBC Cha ter 15.
. Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit NBLD7L711
FINAL
Building Numbers - 5" numbers of contrasting color
posted near main entrance of house and visible from
street per City Ordinance
Final -Building ~ O r/ ~ ~D
(GENERAL CONDITION
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. If temporary erosion and sediment control (TESC) measures are required, they shall be installed on-site
and inspected prior to beginning constrnction; call 385-2294. Measures shall include installation of silt
fencing end graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept
free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
L.J
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report correMions are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits expire if no progress has been made within aiz months, or if no inspections are done
by the Building Department within one year. Cali for at least one inspection per year to ktep your
building permit active.
9. Revisions require submittal 8c approval prior to making changes in the field. Contact the BnOding
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2