Permit Number: $LDO2-21 O Issued: 10/31/02 Parcel Number: 943-320-009
Job Address: 1256 Center Street Zoning: RR=II Type: V_N Occupancy: RR=3
Total Occupant Load: NC Nature of Work: Single-family Residential Addition /Remodel
Owner: Christiane Hale and Irvin Emanuel Contractor: Unknown -See General Condition #1 below
GENERAL CONDITIONS APPLY: See last pace
SEPARATE PERMTTS REOUIIiED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
All engineered details including holdowns, shear walls, strapping &
connections require inspection prior to cover
REQUIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL See
General Condition #2
Rights-of--way shall be kept free of dirt and debris from
construction site
FOOTINGS -per engineered details Sheet 53.1 Pct. S' Z 5 0 3 ~- CL-
Setbacks
~ C a ~ ~~
Footings
Forms
Reinforcement -Grade 60
Vertical steel 18" o.c. w/alternating hooks-in
place @ footing inspection
Interior Footings
Porch/Deck Piers
•
CALL 48 boors before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
Building Pamil #BI.D02.210
REQUIRED INSPECTIONS APPRnVF:nmATF.
FOUNDATION -per engineered details, Sheet S3.1
Stem Wall ~ S ~ ~ S ~~
Forms ~ ~ L ~
Reinforcement -Grade 60 (~pw ~-v ~-
AnchorBolts & Washers
Foundation Vents
Crawl Access
Beam Pockets
FLOOR FRAMING
Girders
Joists - U210 hangers
Blocking
Shield under Post
4 x Posts DF#1
Positive Connection
Girder to Concrete
Treated Wood to Concrete
Anchor Bolts & Washers
Sheathed Pony Walls
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hamner Arrestor
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
MECHANICAL
-Heat Pump/Air Handler
Electric Heat Pump
Marmfacturer's installation instructions to be on-site @ time
of inspection.
Ducts & Duct Insulation -Supply/fresh air ducts in
conditioned space: R-4; heating ducts in unconditioned
space: R-8
See Neat Page
.J
Ca1148 hours before yon dig for utility line locates
1-800-424-5555
Page 2 of 4
Building Permit #BLD02.210
•
REQUIRED INSPECTIONS
APPROVED/DATE
MECHANICAL continued
Whole House Ventilation
HVAC Integrated Fresh Air
7" Smooth Duct minimum
Terminal Element - 8"
Clock timer on furnace fan
Other than motorized damper requires letter of certification
for flow rates.
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
FRAMING v~(UJ ~ Qu4 OK ZR o3
Walls
Engineered Shear Walls
Roof Framing per Sheet 52.3
Blocking
Attic venting -ridge & eave
~}~ ~p' (~~D ~
Posts, beams and headers l
Positive Connections per Sheets S6.1 and S6.2
Window U-factor -per schedule; see credit calculations
NFRC sticker must be on windows & doors ar
dme of inspection
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-3~
Cam-, ~3~83
_
Walls (R-19) (
Vapor Barrier -faced sta led backed batts _
~ _
6 ack poly in crawl space -seams lapped 12"
o
~ ~0~3 03
DRYWALL NAII.ING
Walls ' /
~j (d f`7.{D~
Ceiling - II
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
~.._ -.~
REQUIRED INSPECTIONS
FINAL - - -- --
HouseNumbers - 5" numbers.
Plumbing „ /~~~ ~
~ `Ce/
Mechanical/Ileating
Insulation ertificate
Fresh Air Certificate fit ~~, 63
mo e e ors
Final -building
~~ c~ l~ le
Buadiog Pamil #BLD02d 10
APPR()VFiI/IIATF
GENERAL CONDTITONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of sik fencing
and graveled construction entrance (see attached details). Adjacent rightaof--way shall be kept free
of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, eta
once construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corcections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within siz months, or if no inspections
are done 6y the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
9. Revisions require review and approval rior to making changes in tbe field. Contact the Building
Department at 379-5086 prior to msldng changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-S555
Page 4 of 4