Loading...
HomeMy WebLinkAboutBLD02-208Waterman & Katz Bnildl~g 181 QWnq Street, Sdte 301 Pnrl Towmend, WA 98368 Fhone: 360379-5086 Faa 360J65-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOZ-ZOgR-2 Issued: 03/19/03 Parcel Number: 101 351001 Job Address: 200 Battery Wav BIdQ. #229 Zoning: P/OS Type; VV=N Occupancy: RR=3 Occupant Load: 3 Nature of Work: Revision #2: Revised enaineerin¢ for foist blockinE, veneer anchors aarapet bracin¢ at roof north wall ledger beam connector and staale saecs Owner: Washington State Parks -Fort Worden Contractor: Hoch Construction - HOCHCI' 160NT GENERAL CONDITIONS APPLY: See last sage SEPARATE PERMITS REOUIItED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 NOTE: See also original Inspection Record RF.fIiITRF,n INSPECTIONS APPROVED/DATE All engineered details require inspection prior to cover FLOOR FRAMING Joists Blocking - APA plywood FRAMING -per engineered details Lag Screws to replace veneer anchors Parapet bracing at roof North wall ledger Concealed beam connector - CTI'6 16 gage staples with revised spacing • CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 2 Building Pem~it #02-20gR-2 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accoroplished. 2. Temporary erosion and sediment controt (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall, be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to schedulin¢ the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval rior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800.424-5555 Page 2 of 2 Wa[ermm & Kati BWIdIng 181 QWnq Street, Sulfa 301 Port Towmrnd, WA 98368 Phone: 368379-5086 Fa:360385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOZ-2U8R-1 Issued: 02/18/03 Parcel Number: 101 351 001 Job Address: 200 Battery Wav Bldg. #229 Zoning: P/OS Type: V-N Occupancy: R=3 Occupant Load: 3 Nature of Work: Revision #1: Engineering for F-2, F-3 & roof foist connections Owner: Washington State Parks -Fort Worden Contractor: Hoch Construction GENERAL CONDITIONS APPLY: See last page SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 NOTE: See also originallnsnection Record REQUIRED INSPECTIONS APPROVED/DATE All engineered details require inspection prior to cover FLOOR FRAMING Joists Engineered Hangers A 23 Framing Angles Lag Screws LVL Sisters FRAMING -per engineered details Roof joists DF #1 Sisters A 23 Framing Angles Straps Lag Screws Blocking CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 1 ~~ W.termao & xnt: Bulldtng IBl Qufney Street, Suite 361 Port Towwend, WA 94163 PAone: 360379-5086 Fa:363.335-7675 CITY OF PORT TOWNSEND ~~ CONSTRUCTION PERMIT & INSPECTION RECORD TffiS CARD MUST BE POSTED AT CONSTRUCTION STTE Call 385-2294 for Inspection Permit Number: BLDO2-2O8 Issued: 10/16/02 Parcel Number: 101351001 Job Address: 200 Battery Wav BIdQ. #229 Zoning: P/OS Type: V-N Occupancy: R=3 Occupant Load: 3 Nature of Work: Structural improvements to rental "castle" Owner: Washington State Parks -Fort Worden Contractor: TBD -see condition !11 GENERAL CONDITIONS APPLY: See last cage SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 NOTE: Special inspection is required for concrete per UBC Section ]701.5, Item #I. Special Inspector shall be a Washington licensed engineer or ICBO cert~ed inspector. ICBO certified inspector should either be listed in the current edition of the WABO Agency and Inspector a 'stet or present credentials to the Building Department prior to performing inspections. Required Speciallnspection Reports shall indicate compliance with the plans and specifications and shall be copied to the Building Department in a timely manner. Permit Holder or Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by required special inspections. RF.I7iTiRF.n iNSPF,CTinNS APPROVED/DATE All engineered details require inspection prior to cover DEMOLITION All materials from demolition shall be taken to an approved landfrll or disposal site meeting all qualifrcations as set forth by scat cal-1 FOOTINGS -per engineered details; special inspection required for 3000 psi concrete Corbel Details Reinforcement -per engineering; grade 60 steel UFER CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 4 i' Building Permit p02-208 RE UIRED INSPECTIONS APPRf1VF:n/IIATF. FOUNDATION -per engineered details; spe al inspection required for 3000 psi concrete undation Wall Gr e C~~~ ~ Reinforcement -per engineered details; grade 60 steel Anchor Bolt & Washers - 5/8" er e i i i N'V ~^~ ~ o~~ ~ p ng s neer ng Engineered Connections ~o I ~ (6 3 l Engineered Roldowns ~- j Crawl Access FLOOR FRAMING Joists Blocking Engineered Rangers } Framing Anchors q ~ ~ /i1 V ~ Engineered Floor Straps Positive Connections Treated Wood to Concrete Anchor Botts & Washers Floor Sheathing/Nailing PLUMBING - no changes proposed MECHANICAL - no changes proposed FRAMING -per engineered details Walls Engineered shear walls Blocking ~ Z 1 Roof Positive Connections Framing Anchors Veneer Anchors ~j(~L'AK, t/(6.tu.-S 6 ~~~~~ Engineered beams and headers with HUSC hangers Para et and ara et bracin @ walls & roof ~ ~ 2v~f 3rd r® ~ r ~'' g p p p - c~"y~`~ 3 Windows -escape Windows -safety glazing ~,. ~ ~ 3 B '~~pn.-„v6 /J ~,~5 ~d ~LAOiL- Window U-factor - .40 or better ~/ylDa nn ' -/ 'l ( Air Seal " 6 Fireblocking 1 Weather Resistive Barrier Call 48 hours before you dig for utility line locates I-800-424-5555 Page 2 of 4 1 s: Buildin8 PermN k02408 ATil1TTTRFTI iNCPFf Ti(lNC APPRnVED/DATE INSULATION) Fill all exposed floor, wall and ceiding/roof cavities Baffles Vapor Barrier required 6 mil black poly in crawl space DRYWALL NAILING W ll ~ 3 f~3 `PQ SS2.~ ~P~, a s Ceiling Ll, ~ Go„~,.~ FINAL LPG (if applicable) Building Numbers Insulation Certificate (if applicable) Vapor Bamer Paint Certificate (if applicable) Smoke Detectors Stairs, Decks & Landings Final -building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Z. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building PumA HM-111g 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is reauired. Public Works aooroval 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits ezpire if no progress bas been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the Held. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST TffiS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 ~_