Loading...
HomeMy WebLinkAboutBLD02-207wa~amm&xatzanaaio8 isi rn~r s~ sma 3oi Pat Tamund, WA 98368 Phone (360) 379-3208 Fex (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD I THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: $LDU2-2U7 Issued: 09/17/02 Parcel Number: 948 308 501 Job Address: 101619th Street Zoning: RR=II Type: VV=N Occupancy: R-3 Total Occupant Load: No Change Nature of Work: Repair and replace 360 sa. ft. uotrer deck and chance location of stairs. Owner: Barry Remsbera ContraMor: Tonv Goldenber¢ - GOLDEC*075NC (385-6958) GENERAL CONDITIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS APPROVED/DATE DEMOLITION All construction debris to be deposited in Jefferson County Landfill or other location in accordance with all local, state and federal laws. FOOTINGS Setbacks 9~2~/O Z Deck Pier Footings Reinforcement FLOOR FRAMING/DECK All framing members to be pressure treated or wood of natural resistance to decay Posts - 4" x 4" Beam - 4" x 8" and 4" x 10" Joists - 2" x 8" @ 16" o.c. Joist Hangers -Simpson LU28 Positive Connection Post-to-Pier -Simpson CBSQ44 or EPB44 Post-to-Beam Treated Wood to Concrete Lag Bolts @ ledger - 1/2" x 4-1l2" lag screws @24" o.c. or 5/8" x 4" @ 36" o.c. Blocking C~ Call 48 hours before you dig ufllity line locates: 1-800-424-5555 Page I of 2 rye a scoat2m House Numbers posted (minimum 5'~ Guardrails Handrails -required for 4 or more risers Stairs Landings Smoke Detectors throughout existing construction per 1997 UBC Deck -Final GENERAL CONDTITONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of sik fencing and graveled construction entrance (see attached deta~7s). Adjacent rights-of-way shall be kept free of dirt debris. Soils exposed during construction shall be temporar0y stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, eta once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering inclutding:nailing, 6oldowns, sheathing, and alternate braced wall panels • (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection oa your project until Public Works requirements have been completed snd inspected. For Public Works inspection call 385-2294. A 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential projecK. 8. All building permits ezpire if no progress has been made within sa months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal 8c approval prior to making changes in the field. Contact the Building Department Q 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig utility line loptes: 1-800.424-5555 Page 2 of 2