Loading...
HomeMy WebLinkAboutBLD02-203Watzrman & Katz Building I S I Quinry Street, Suite 30I Pon Towiuend, WA 98368 Phone: (360) 379-3208 Faz: (360) 385-7675 ~- CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOZ-ZO3R-2 Issued: 06/03/03 Parcel Number: 931 700 505 Job Address: 2611 Sheridan Avenue Zoning: RR=II Type: VV=N Occupancy: RR=3 Nature of Work: Revision #2• change tvpe of siding and insulation, replace BCIs with floor and ceiling foists and rafters• change location of whole house fan to bathroom #2. Owners: Jeffrey Youde and Kristin Becker Contractor: Owner (379-5430) GENERAL CONDITIONS APPLY -SEE BELOW SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See oriizinal permit BLD02-203 for other inspections. RE UIRED INSPECTIONS APPROVED/DATE FRAMING -changed from BCis r Second Floor Joists 2 x 10 structural select DF -span OK ~~'~ ~_ ~~~~o ~ ~_ to First Floor Joists 2 x 8 structural select DF -span OK to ' " ~~ ~ ~ ~ ~ ~~~ 15 1 INSULATION J~~C , ~ G, f G /S o~ ~ " Wall Insulation - veri R-23 Bibs; R-21 re uired. . ., a . Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Pemtic %BLD02-2038-2 FINAL House Numbers -check for 5" numbers Smoke Detectors Final -Building ENERAL CONDITION 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass fmal inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works aooroval must be received arior to scheduline the Buildin¢ Department's final inspection. 7. Final InspeMions are required prior to occupancy; a Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. CaII for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 wmaa~axeasa~a~ tat ~r saea, suite 3oi Pat Towmald, WA 98368 Phone: (360) 3793208 Fa: (360)3867675 CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection CITY OF PORT TOWIVSEND Permit Number: BLDO2-ZO3R-1 Issued: 11/20/02 Job Address: 2611 Sheridan Avenue Zoning: RR=II Nature of Work: Revision #1: construct 128 sa. ft. front oorch Owners: Jeffrey Youde and Kristin Becker GENERAL CONDITIONS APPLY -SEE BELOW SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 Parcel Number: 931 700 505 Type: ~-N Occupancy: RR=3 Contractor: Owner (379-5430) NOTE: See original Hermit BLD02-203 for other inspections. REQUIRED INSPECTIONS APPROVED/DATE FOOTINGS Setbacks Footings, Reinforcement Post Base/Positive Connection Treated Wood to Concrete FRAiVIING -Inspections may be done at same time as Final if all elements of construction are available for 17GSpECt10)J Pressure Treated Posts Positive Connection Ventilation Rafters Ceiling Joists Hangers Blocking Seismic Ties Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 ramie ast,~oz-zone t FINAL House Numbers -check for S" numbers Smoke Detectors Final -Building ENERAL CONDITION 1. Contractors working on this project are required to have a Labor & Industries co~rtractor's registration nwnber and a City business license. Failure to provide proof of this documentation prior to work may resuk m job shut down while this is accomplished. 2. Temporary erosion and sediment control (1'ESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shalt be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including Waiting, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspectioW on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of tweMv-four DeoartmenPs foal insnection. 7. Fmsl Inspections are required prior to occupancy; a Certificate of Occupancy is required for a Woo-residential project. 8. All building permits expire if no progress has been made within siz months, or if no inspections are dog by the Building Department within one year. Call for at least ooe inspection per year to keep your building-permit active. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 Waterman S KatzBuilding 181 Quincy Street, Suite 301 Port 1'owmend, WA 98368 Plane: (360) 379-3208 Fax: (360) 385.7675 CITY OF PORT TOWNSEND CONSTRUCTION PERNIIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION STTE Call 385-2294 for Inspection Permit Number: BLDO2-2O3 Issued: 09/11!02 Parcel Number: 931700505 Job Address: 2611 Sheridan Street Zoning: R'II Type: VV=N Total Occupant Load: 3 Occupancy: R-3 Nature of Work: Construct Sinele family residence Owner: Jeffrey Youde & Kristin Becker Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMTTS REOUHtED: Electrical -Contact Labor & Industries @ 360-417-2702 REQUIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks ~0~ ~~ Footings / Forms Reinforcement Interior Footings LIFER Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page i of 4 Permit p BLD02.203 REQUIRED INSPECTIONS APPROVFD/DATF. FOUNDATION Stem Wall Forms r O~d ~~O7j Reinforcement Anchor Bolts & Washers Vents -10 required Crawl Access FLOOR FRAMING Foundation Cripple Wall / nn i U' (L(l0Y ~ "(/ Joists - BCI plan to be o»~ite at time of inspection ff `'( Blocking Treated Wood to Concrete Positive Connections Rough-In (D-V-T & Clean outs) ~ ~ ~, ,O (~ (~-, / 5' ~~ ~b V L/ b ater Supply mater a~mmer restor clothes and dishwasher Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water HeaterBoiler Seismic Restraint - 2 places Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL Whole House Fan - @ laundry Source Specific Fans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 RF(1TiTRFTI TNCPRf TT(1NS APPROVED/DATE Pumil # HLD02-203 FRAMING --- -- - - - - - - - alls ~ ~ ' Posts, Headers & Beams Ceiling/Roof - -engineered BCI plan on- site @ time of inspection n ~} n Rafter Positive Connectio Roof Venting - @ soffit r / ~ ~ ~ Windows -escape O j Windows U-factor - .40 or better NFRC window sticker must be on windows and doors at inspection time Fresh Air Intake (Wall Ports) Doors U-factor - .20 or better Fire Blocking Weather Resistive Barrier INSULATION Floor (R30) ~ ~ . Walls-(R=21) Ceiling - (R=38) ~~ C^ , ~ ~!~ ~^ I r BafT]es __ ___ _ __- ___ _ ------ -r- "~aporBarrier: paint .i mil black poly in crawl space DRY WALL NAILING Walls 4 Ceiling ~' ` Enclosed Usable Space under Stairs L .- 4 ~ - ~~ FINAL Public Works Sign-Off ~ l-~ House Numbers - 5"minimum Pl bi / c~ . ~ ng um ~ Mechanical/Heating Insulation Certificate Vapor Barrier Paint Certificate Smoke Detectors Final -Building Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 ~~ Pmnit A 8LD02-203 ~ '~ {_. 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 3852294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. So~7s ezposed during construMion shah be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for proteMion of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspeMion on your projeM until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenri-four hours notice is required Public Works approval must be received prior to schedulin¢ the Buildine Department's final insnection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon- residential project. 8. All building permits ezpire it no progress has been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval. prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Cal[ 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4