HomeMy WebLinkAboutBLD02-203Watzrman & Katz Building
I S I Quinry Street, Suite 30I
Pon Towiuend, WA 98368
Phone: (360) 379-3208 Faz: (360) 385-7675
~-
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOZ-ZO3R-2 Issued: 06/03/03 Parcel Number: 931 700 505
Job Address: 2611 Sheridan Avenue Zoning: RR=II Type: VV=N Occupancy: RR=3
Nature of Work: Revision #2• change tvpe of siding and insulation, replace BCIs with floor and ceiling foists
and rafters• change location of whole house fan to bathroom #2.
Owners: Jeffrey Youde and Kristin Becker Contractor: Owner
(379-5430)
GENERAL CONDITIONS APPLY -SEE BELOW
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
NOTE: See oriizinal permit BLD02-203 for other inspections.
RE UIRED INSPECTIONS
APPROVED/DATE
FRAMING -changed from BCis r
Second Floor Joists 2 x 10 structural select DF -span OK ~~'~ ~_ ~~~~o ~
~_
to
First Floor Joists 2 x 8 structural select DF -span OK to
'
" ~~ ~ ~ ~ ~ ~~~
15
1
INSULATION
J~~C
, ~
G, f G /S o~
~
"
Wall Insulation - veri R-23 Bibs; R-21 re uired. . .,
a .
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Pemtic %BLD02-2038-2
FINAL
House Numbers -check for 5" numbers
Smoke Detectors
Final -Building
ENERAL CONDITION
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass fmal inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works aooroval must be received arior to
scheduline the Buildin¢ Department's final inspection.
7. Final InspeMions are required prior to occupancy; a Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. CaII for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
wmaa~axeasa~a~
tat ~r saea, suite 3oi
Pat Towmald, WA 98368
Phone: (360) 3793208 Fa: (360)3867675
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
CITY OF PORT TOWIVSEND
Permit Number: BLDO2-ZO3R-1 Issued: 11/20/02
Job Address: 2611 Sheridan Avenue Zoning: RR=II
Nature of Work: Revision #1: construct 128 sa. ft. front oorch
Owners: Jeffrey Youde and Kristin Becker
GENERAL CONDITIONS APPLY -SEE BELOW
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
Parcel Number: 931 700 505
Type: ~-N
Occupancy: RR=3
Contractor: Owner
(379-5430)
NOTE: See original Hermit BLD02-203 for other inspections.
REQUIRED INSPECTIONS
APPROVED/DATE
FOOTINGS
Setbacks
Footings, Reinforcement
Post Base/Positive Connection
Treated Wood to Concrete
FRAiVIING -Inspections may be done at same time as
Final if all elements of construction are available for
17GSpECt10)J
Pressure Treated Posts
Positive Connection
Ventilation
Rafters
Ceiling Joists
Hangers
Blocking
Seismic Ties
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
ramie ast,~oz-zone t
FINAL
House Numbers -check for S" numbers
Smoke Detectors
Final -Building
ENERAL CONDITION
1. Contractors working on this project are required to have a Labor & Industries co~rtractor's registration nwnber
and a City business license. Failure to provide proof of this documentation prior to work may resuk m job shut
down while this is accomplished.
2. Temporary erosion and sediment control (1'ESC) measures shall be installed on-site and inspected prior to
beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shalt be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is
responsible for protection of adjacent properties.
3. All elements of engineering including Waiting, holdowns, sheathing, and alternate braced wall panels (ABWP)
require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspectioW on your project until Public Works requirements
have been completed and inspected. For Public Works inspection call 385-2294. A minimum of tweMv-four
DeoartmenPs foal insnection.
7. Fmsl Inspections are required prior to occupancy; a Certificate of Occupancy is required for a Woo-residential
project.
8. All building permits expire if no progress has been made within siz months, or if no inspections are dog by the
Building Department within one year. Call for at least ooe inspection per year to keep your building-permit
active.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Waterman S KatzBuilding
181 Quincy Street, Suite 301
Port 1'owmend, WA 98368
Plane: (360) 379-3208 Fax: (360) 385.7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION STTE
Call 385-2294 for Inspection
Permit Number: BLDO2-2O3 Issued: 09/11!02 Parcel Number: 931700505
Job Address: 2611 Sheridan Street Zoning: R'II Type: VV=N Total Occupant Load: 3
Occupancy: R-3 Nature of Work: Construct Sinele family residence
Owner: Jeffrey Youde & Kristin Becker Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUHtED:
Electrical -Contact Labor & Industries @ 360-417-2702
REQUIRED INSPECTIONS APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
~0~
~~
Footings /
Forms
Reinforcement
Interior Footings
LIFER
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page i of 4
Permit p BLD02.203
REQUIRED INSPECTIONS
APPROVFD/DATF.
FOUNDATION
Stem Wall
Forms
r O~d ~~O7j
Reinforcement
Anchor Bolts & Washers
Vents -10 required
Crawl Access
FLOOR FRAMING
Foundation Cripple Wall / nn
i U' (L(l0Y ~ "(/
Joists - BCI plan to be o»~ite at time of inspection ff `'(
Blocking
Treated Wood to Concrete
Positive Connections
Rough-In (D-V-T & Clean outs) ~ ~ ~, ,O (~ (~-, / 5' ~~
~b V L/ b
ater Supply
mater a~mmer restor clothes and dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water HeaterBoiler
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
Whole House Fan - @ laundry
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3' from
openings)
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
RF(1TiTRFTI TNCPRf TT(1NS
APPROVED/DATE
Pumil # HLD02-203
FRAMING --- -- - - - - - - -
alls
~ ~ '
Posts, Headers & Beams
Ceiling/Roof - -engineered BCI plan on-
site @ time of inspection
n
~} n
Rafter Positive Connectio
Roof Venting - @ soffit r / ~
~
~
Windows -escape O
j
Windows U-factor - .40 or better
NFRC window sticker must be on windows
and doors at inspection time
Fresh Air Intake (Wall Ports)
Doors U-factor - .20 or better
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R30) ~ ~ .
Walls-(R=21)
Ceiling - (R=38)
~~ C^ , ~ ~!~
~^ I r
BafT]es __
___ _
__-
___
_ ------ -r-
"~aporBarrier: paint
.i mil black poly in crawl space
DRY WALL NAILING
Walls
4
Ceiling ~'
`
Enclosed Usable Space under Stairs L .- 4 ~ - ~~
FINAL
Public Works Sign-Off ~ l-~
House Numbers - 5"minimum
Pl
bi / c~ .
~
ng
um ~
Mechanical/Heating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
~~
Pmnit A 8LD02-203 ~ '~
{_.
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 3852294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. So~7s
ezposed during construMion shah be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for proteMion of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspeMion on your projeM until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenri-four hours notice is required Public Works approval must be received prior to
schedulin¢ the Buildine Department's final insnection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits ezpire it no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval. prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Cal[ 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4