HomeMy WebLinkAboutBLD02-179wazao,~~u~su;m~
181 Quincy Street, Suile 301
Port Townsad, WA9S368
r(woe: (360)379-3208 rte: (36o)ass-7c~s
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11 3 8 5-2294 for Inspection
Permit Number: BLD02-179R-1 Issued: 11/25/02 Parcel Number: 951-904-011
Job Address: 4821 Mason Street Zoning: R-I Type: VV=N Occupancy: R-3/U-1
Total Occupant Load:No Chance
Nature of Work: Revision #1: add 4 new windows on south kitchen wall oer attached eneineerinz.
Owner: Tack and Marsha Hensel dba Hensel Investments
Contractor: Seven Bridles Proaerties. LLC - SEVENBP983JD
GENERAL CONDTITONS APPLY -SEE LAST PAGE
SEPARATE PERNIITS REOUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
See Original Permit BLD02-179 for other insuections.
REQUIRED INSPECTIONS
APPROVED/DATE
FRAMING
Walls - %2" sheeting with 8d's @ 4" o.c. above and below
windows
~ ~( OZ
Windows Ufactor - .40 or better
NFRC window sticker must be on windaws and doors
at inspection time
DRYWALL
Engineered nailing at kitchen/master bedroom wall - 6d's @
4" o.c. both sides
FINAL
Building -See also original permit #BLD02-179
for house construction
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page i t3f 2
PamitMBLD0Yl79a•1
(:F.NFRAi. f'ONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
resuk in job shut down while this is accomplished.
2. Temporary erosion and sedunent control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, eta Soils
shall be permanently stabilized with seeding, plantings, sodding, etc, once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including ns~7kng, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any end aU defici~ckes noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass fmal inspection oq your project until Public Works
requirements Gave been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works annroval must be received nrior to
scheduling the Building Department's final insoection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Departmem within one year. Call for at least one inspection per year to keep your
bwlding permit actives
9. Revisions require submittal and approval rior to mating changes in the field. Contact the Building
DepardneM (379-3208) prior to making changes to the approved pleas.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
wntetmm a 1cm~Bu;tdc,e
181 tTtiney Street, Suite 301
Pat Townsend, WA98368
Phase: (360) 379-3208 Fu: (360) 3B3-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-179 Issued: 10/01/02 Parcel Number: 951904 011
Job Address: 4821 Mason Street Zoning: R-I Type: VV=N Occupancy: R-3/I1-1
Total Occupant Load: 612 Nature of Work: Construct sinele-family residence with attached ¢arase
Owners: Jack and Marsha Hensel dba Hensel Investments Contractor: Seven Bridees Prooerty. LLC-
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUIItED:
Electrical -Contact Labor & Industries (a3 360-417-2702
NOTE: All elements of engineering require inspection prior to cover
• Prior to framing inspection, applicant mustobtain tenor Improvement Permit from Public Works.
INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving the site
FOOTINGS
Setbacks l~
Q/
Footings ~
~
I`
Forms
Reinforcement
Interior Footings
Por eck Piers
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
«~~
REQUIRED TIVSPF.CTT(]NC
s vvu n~~~ m ~ m~
-- --- - ----
FOUNDATION u,. :~... i.a.i YCaia,
Stem Wall
Forms Is
IO
Reinforcement /
/07j
Anchor Bolts & BP washers
Vents -13 required
Crawl Access
FLOOR FRAbIING
Joists -engineered BCI plan shall be on-site at dme of Inspection
Beams
/~ <~f111
Blocking ( ("1~/
Positive Connections
Treated Wood to Concrete
Anchor Bolts & Washers
Beam Pockets
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply ~ ~/
cO D
Gas Supply
Water Hammer Arrester (a3 clothes & dishwashers
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Vaive if> 80 psi
Water Heater
R 10 under
Seismic Restraint -strap tank @ 113 points
18" A. F. E
Pressure relief valve drain to exterior, terminate 6" - 24" above
ground '
CAL
Electric Hea mp pro U,.1~ ~, c 6ZG
f P r ~ "~
amr actu Ration instructions to be on-site Qa time of ~ ZS 1 p 3 ~ ~L
InSpecti07T.
Ducts ct Insulation -Supply/fresh air ducts in conditioned
s
ace: R-4; heatl»
ducts in unconditioned
R
8
~ ~ "~~'~
p
g
space:
-
Whole House Ventilation I
I ~ f ~f ~ Ti
HVAC Integrated Fresh Air
7" Smooth Duct minimum
Terminal Element - 8"
Clock timer on furnace fan
Other than motorized damper requires letter of certiflcadon for
flow rates.
Cal! 48 hours before you dig for ut~7ity 6ne locates
1-800.424-5555
Page 2 of 4
r
~~8~~~
REQUIRED INSPF,('_TinN~ Appu nv>r, n/n a TF
MECHANICAL continued
LPG Stoves -provide specs on-site
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
FRAMING
Prior to framing inspection, applicant must obtain tenor
Improvement Permit from Public Works.
~
Walls-Engineered ~
G~~~L-
Shear walls
Ceilings/floor -engineered BCI plans to be on-site
Roof-Engineered truss plan to be on site at inspection
Blocking
Truss Positive Connections
Roof Venting - eave and ridge vents
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better for unlimited glazing
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake - HVAC Integrated option
Doors U-Factor - .20 or better/Rated doors @ garage/house
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-21)
~ 2~~3
Ceiling (R-38) f "
Vapor Barrier: paint
Baffles ~
6 mil black poly
DRY WALL NAILING
Interior braced wall panels per engineered plan
~O' ~ /~~
U~~
Walls U
!
(~
Ceiling
Garage/fiouse Occupancy Separation
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
~.ffi.~-~~
FINAL
Public Works Sign-Off
LPG
House Numbers - 5" minimum
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Fresh Air Certification from Installer
Smoke Detectors
Final -Building
2~ X03 ~ lea~b ~~
~~ C,L ~-- co.~~,
GENERAL CONDITION
1. Contractors working on this project are required to Gave a Labor & Industries contractor's registration
num r and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for proteMion of adjacent properties.
3. All dements of engineering induding nailing, holdowns, sheathing, and alternate braced wall panda
•
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are complded.
6. The Bu~7ding Department is unable to pass final inspection on your project mrtil Pubfic Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within aiz months, or if no inspections are done
by the Building Department within one year. Calf for at least one inspection per year to keep your
building permit active.
9. Revisions require sabmittal and approval rior to malting change in the 5dd. Contact the BuOding
Department (379-3208) prior to malting changes to the approved pleos.
10. POST TffiS PERMIT ON-SITE WITH THE APPROVED PLANS. ~.
Call 48 hours before you dig for. utility line locates
1-800.424-5555
Page 4 of 4