Permit Number; BLD02-176 Issued: 08/19/02 Parcel Number: 946800605
Job Address: 355 E Street Zoning: R_H Type: VV=N Occupancy: R_3
Total Occupant Load: NC Nature of Work: Remodel of Sin¢le-family Dwelling
Owner: Felix Misch Contractor: Same as Owner
GENERAL CONDITIONS APPLY: See Last Pace
SEPARATE PERMITS REOUII2ED:
Electrical Permit -Contact WA Slate Dept. of Labor & Industries 360-417-2702
RF.nTTiRF.n TNSPF.( TTONS
APPROVED/DATE
DEMOLITION
Materials from demolition shall be taken to the Jefferson
County Landfr77 or other approved off-site location
meeting all state and local codes
FOOTINGS
Porch Footings
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestors @ clothes & dishwasher
G~5 ~l~$' ~~,~/~
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Straps
Pressure Relief Valve Drain to exterior; elbow down,
6" - 24" above ground
CALL 48 hours before you dig for Utility line locates
I-800-424-5555
Page 1 of 3
Building Permit p02-1~6
RE UIRED INSPECTIONS APPROVED/DATE
MECHANICAL
Bath/Laundry/KitchenFerns
Environmental Air Exhaust ducting (with backdraft
dampers), insulation (R-4) and termination (3' from
openings into building)
FRAMING
Wails
Engineered Beams & Headers
Ceiling
2nd Story Roof Deck Framing -per engineering -
Attic Venting ~,
Roof -engineered roof framing
Alternate Roof -engineered truss plan to be on-site at
time of inspection
Window/Skylight U-Factor - .40 or better
NFRC stickers shall be on-site at time of inspection
Windows -safety glazing
Windows -escape
Positive Connection f~,
Blocking D
Air Seal
Fireblocking z
Weather Resistive Barrier ~
,
~ Z ~2~`~
INSULATION
Filf exposed cavities ~
Vapor Barrier Paint/Faced Batts
Baffles "
~~
DRYWALL NAILING 1
walls Pas~.d 31~~a3
Ceilings ~ G~ i,~. Gp y,,.~v(-Pi;
FINAL
House Numbers -minimum 5" numbers
Deck
Plumbing
MechanicaVFIeating
Insulation Certificate if applicable
Vapor Barrier Paint Certificate if applicable
Smoke Detectors throughout
Final -building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Building Pmnit #02-176
. GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's re¢istration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and alf deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works aaaroval
must be received arior to scheduling the Building Department's final inspection.
7. Ffna! Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMTT ON-SITE WITH THE APPROVED PLANS.
Cali 48 hours before you dig for utility line locates
1-800.424-5555
Page 3 of 3
w
C
•