HomeMy WebLinkAboutBLD02-173Waterman R Katz Buildi~
181 Quincy SIRet, Suita 301
Pon Towmend, WA 98363
Phone: (360) 379-3208 Fex: (360) 335•'!6'!3
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO2-173 Issued: 08/30/02 Parcel Number: 988 802 007
Job Address: 1055 Monroe Street Zoning: RR=II Type: VV=N Total Occupant Load: NC
Occupancy: R-3 Nature of Work: Add new Deck
Owner Harrv Smvth
Contractor: Jim Poore- That'll Do Fine Carnentrv
POOREJ*982L5
****All elements of engineering including require inspection prior to cover****
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REQUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
• RE UIRED INSPECTIONS
APPROVED/DATE
DEMOLITION
Materials from demolition shall be hauled to the Jefferson
County Landfill or other approved areas off-site in accordance
with state and local laws
FOOTINGS
Setbacks
/
Forms ~/ (~ y
Deck Footings (((
Porch Footings
Reinforcement - unreinforced OK per engineer
• Ca1148 hours before you dig Tor utility line locates
1-800-424-5555
Page 1 of 3
r~exaLDm-~n '
REQUIRED INSPECTIONS APPROVED/I)ATF,
FRAMING -all deck framing members to be treated or wood
of natural resistance to decay
Posts
Beams
Porch Roof Header
Joists
Hangers
Blocking
Positive Connections Post-to-Footings
Positive Connections Posts-to-Beams
Rafter Positive Connection
~~/Z~OZ ('j/
"`"""~~~
FINAL -see also original inspection record
House Numbers -minimum 5" numbers
Smoke Detectors throughout existing construction
Deck
Guardrails /
~ ~ J Z ~P~~7i
Landings I
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspeMed prior
to beginning construMion; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacentrights-of--way shall be kept free of dirt debris. Soils
ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 3
~ Permll#BLDW-173
6. The Building Department is unable to pass final inspection on your projeM until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294,
scheduline the Buildine Deuartment's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
,J