HomeMy WebLinkAboutBLD02-158wateman a xstz eeaau~
181 Quvwy Street Suile 30I
Pmt Towmend, WA 98368
(Phone}379-3208 (Fex)383-7673
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO2-158 Issued: 08/02/02 Parcel Number: 957 607101
Job Address: 313 Decatur Street Zoning: CC=II Type: VV=N Occupancy: B
Total Occupant Load: 5
Nature of Work: Tenant Imarovement for Beauty Shop: add sinks, water heater, ADA restroom, heat. and
replace front window.
Owner: Barbara Engstrom Tenant: Robin Stemen
Contractor: Owner -See Condition #1
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
Sign Permit
REQUIRED INSPECTIONS
APPROVED/DATE
DEMOLITION
Materials from construction shall be deposited in
approved areas o, jf-site in accordance with all state
and local laws and ordinances.
PLUMBING - gamer Free design required
Contractor to verb that existing sewer is sized to ~ ~ t-}~, / ~2 ~OZ /~J
~ ~/ U
/
~/
accommodate additional fixtures. (,
~
Drain Waste & Vent, Traps, Clean-outs
Water Supply
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Fixture & Mounting Heights
Floor Drains require trap seal protection
Water Heater -seismic straps
- R-10 under if electric & on slab
•
Page 1 of 3
Building I'emilt #BLD01-138
REQUIRED INSPECTIONS
APPROVED/fIATF. ~
MECHANICAL
Exhaust Fans -workroom and bath
Environmental Air Exhaust ducting (with backdraft
damper), insulation (R-4) and termination (3' from
~ //2~~
building openings) /
FRAMING -Barrier-Free Design Required
Walls -New interior demising walls
Positive Connections ~/ J'~/~ !~
Ceiling /
Window U-Factor - .4Q or better; safety glazing
Fixture Mounting Heights & Dimensions
LIGHTING
New interior lighting -see attached NREC lighting
budget
DRYWALL NAILING
Walls q
4/~/
~ n//
Ceiling O
~ (~'
FINAL
Property address posted -minimum 5 "numbers of
contrasting color posted near the main entrance of
the building and visible from the street per City
ordinance.
Fire Department Sign-Off
Electrical Sign-Off (I.&n
Plumbing - barrier free design
Wall & Floor Sanitation
Mechanical
Building
Exit
Illumination
Door Signage (min. 1" letters "This door to
remain locked during Business hours" if
locking hardware is on Main Exit)
Barrier-Free
All Doors require lever type hardware.. ,r~
J v~ ~t ~~
1/z" maximum thresholds
New Uni-sex restroom w/ signage
s
L~
Page 2 of 3
Building Pe`mi[ #BI.D02-158
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of sik fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
eaposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works auuroval must be received uriar to
scheduling the Buildine Department's final inspection.
Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within sia months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Buildmg
Department Q 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
C~