HomeMy WebLinkAboutBLD02-148Building and Community Devebpmrnt
Waterman & Katz Building
181 Quincy Street Suite 301
Port Townsend, WA 98368
Phone: (360)379-3208 Fsz: (360)385-7675
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: $LDO2-148 Issued: 08/08/02 Parcel Number: 989 700 401
Job Address: 431 Water Street Zoning: C-III Type: VV=N Occupancy: B
Total Occupant Load: 3 Nature of Work: Set 10 x 32 modular structure as office for Northwest Maritime
Center and Puaet Sound Express
Owner: Northwest Maritime Center
Contractor: L. D. Richert- LCRICC*066L0
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUH2ED:
Electrical -Contact Labor & Industries @ 360-417-2702
NOTE: per Shoreline Exemption L UPOZ-069, modular unit must be removed on or before September
30, 2004 or additional design review approval is required
RF.OTTTRF,T) INSPECTIONS
APPROVED/DATE
TEMPORARY EROSION & SEDIMENT
CONTROL
See general condition #2
FOOTINGS
Setbacks
Chassis Support - 8 pads and piers per diagram
Seismic Tiedowns -per engineering:
1 at each end in longitudinal direction, centered ~/
~'/ ~OZ
4 each side in transverse direction, evenly spaced ///
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Permit # B1,D02-148
REQUIRED INSPECTIONS APPROVED/DATE
FLOOR FRAMING (prior to skirting)
6 mil black poly
Anchors -per a»gineering
CMU Support Piers -per engineer schematic; clearance of I8 "
min. from ground to floor joists; 12 "from ground to chassis;
area arou»d buildi»gs graded to provide runoff away from
portable
l/~ ., / O~
d y
FRAMING: - barrier free required
Door Threshold -max. ''/2"
Deck
Stairs
Landings
Guardrails
FINAL - HPC approval required for revised roof structure
prior to final; TCO may be issued for occupancy prior to
HPC approval '
Fire Department Sign-Off
Electrical (L & n Sign-Off
Building Numbers -minimum S" numbers
Barrier Free Access
Final -Building
No holes or gaps greater than '/. "allowed in skirting.
Skirting to be rated for contact with earth if backfill is involved
Crawl space ve»tilation per installation manual ~ I sq.
ft./ISO sq. ft; located close to corners, on at least two opposing
sides for cross ventilation.
Crawl space access must provide access to all areas under
buildings; minimum 18"x 24"unless specked otherwise;
covered with vi»yl, pressure-treated wood or metal. ~ ~~
~ L
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor dt Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit # BLD02-148
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
• (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
~~