HomeMy WebLinkAboutBLD02-143
Waterman & Ksiz Building
181 Quincy Street Suite 301
Pal Townsend WA98368
(Phoce) 379-3208 (Fax) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION STTE
Ca11385-2294 for Inspection
Permit Number: BLDO2-143 Issued: 8/13/02 Parcel Number: 972903002
Job Address: 5336 Hendricks Street Zoning: RI Type: VV=N Occupancy: RR=3
Total Occupant Load: 3 Nature of Work: Erect vurt for single family residence with attached bath house
L~
Applicant/Owner: Melissa Naav and Ken Slouch Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RFC1TTiRFTI TNCPF('TTfINC
APPRnVF,T)/nATF.
TEMPORARY EROSION & SEDIMENT CONTROL
See General Condition #2
Silt Fence
Drive Off Mat
FOOTINGS -per engineering
Setbacks
Footings /
~/ ~ ~/~~
Deck footings ! l
Bathhouse footings
Yurt footings
Forms
Reinforcement -per engineering
FOUNDATION
Post and Pier
Reinforcement
Positive Connections/PostBgse
Page 1 of 4
Building Permit #BLD02-143
C
REQUIRED INSPECTIONS APPRnVF,17/IIATF.
FLOOR FRAMING - PBS stractural panel floor system
Girders -per engineering
Beams
Joists -loft framing: DF #1
~03
Blocking
Posts
Shield under Posts
Positive Connections -engineered straps '
PLUMBING
Rough-In
Water Supply
Gas Supply
Water Hammer Arrestors @ clothes and dishwasher
Hose Bibbs
~/ J~Q
Pipe Insulation - R-3 I''
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Straps
Pressure Relief Valve Drain to exterior, elbow down,
terminate 6" - 24" above ground
LAICAL
LPG5tove
'
d
F
~q5~ '?~)~~03 te~-
ry
aun
ans C.i~ ~. ~ ,~o
Whole House Fan @ Bath
Environmental Exhaust ducting (with backdraft dampers), ~ L ~ 3
insulation (R-4) and termination (located 3' from /
openings into building)
FRAMING
Engineered shear walls @ bath house
Engineered Beams & Headers
Walls
Ceiling /RR
Roof -engineered truss plan for bath house to be on-site ~
~~ V
at time of inspection
Roof - yurt rafters DF #1
Doors - .26 U-factor or better
Windows - .37 U-factor or better
NFRC sticker to be on windows, doors and skylights at
time of inspection
Skylight -1.11 U-factor
Fresh Air -window ports
Windows -escape
Air Seal
"®
Page 2 of 4
Building Permit #BLD02-143
REQUIRED INSPECTIONS APPROVED/DATE
FRAMING (continued)
Positive Connections
Fire Blocking
Weather Resistive Barrier
INSULATION
"
~-- GL
Q s ~ ~!~ l 0 3
Floor (7.25
stress skin panels) ~
P
Wall (yurt/R-21) ~ ~ ,,-~,,1}~-
Ceiling (yurt/R-38)
Baffles
Vapor Barrier: paint
DRYWALL/NAIIdNG ~ 1
Y 4 SS.e~ 2~ 1 ZC 0~ ~¢~
Y
Walls
Ceiling G L ~ Go ~, /~
FINAL
LPG
y~q S ~ ~~3 ~ U3
`"
House Numbers - 5" minimum
Plumbing ~
Ll, ~ ~~^-~"~'~~
Mecbanical/Heating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Deck/Landings/Handrail s/stairs
Final -Building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall 6e installed on-site and inspeMed prior
to beginning construction; calf 385-229A. Measures sfiall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
. (ABWP) require inspection prior to cover.
Page 3 of 4
Building Pmnit #BLD02-143
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required''
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected For Public Works inspection call385-2294. A
minimum oftwenty-four hours notice is reanired. Public Works approval must be received prior to
scheduling the Building DeaartmenPs final inspection.
7. Fiael Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits ezpire if no progress has been made within sia months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS.
~.
Page 4 of 4