HomeMy WebLinkAboutBLD02-132w,oc~al~s 181 Quiay Skew, S~ti4 301 Pat Tarmeod, WA 98368 PLoke: (360) 3793208 Fex: (360) 385.7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD02-132 Issued: 6/20/02 Parcel Number. 989704304 Job Address: 630 Water Street Zoning: CIII Type: VV=N Occupancy: B Nature of Work: Re-roof with felt base sheet and torch down can over eaistinQ hot mon roof. Repair oaranet sheatbing and install new metal couinQ. Owner: Karen and Jeffery Wbite Contractor: Peak Performance Roofing PEAKPRI990CN GENERAL CONDITIONS APPLY -SEE LAST PAGE REOiJIRED INSPECTIONS APPROVED/DATE DEMOLITION All construction debris to be deposited in Jefferson County Landfill or other location in accordance with all local, state and federal laws. SHEATHING Nailing requires 8d @ 6" o.c. edges & 12" o.c. field or 1 3/." staples @ 6" o.c. edges and field. ROOFING Install all roofing material per manufacturer's specifications and UBC Chapter I5. FINAL House Numbers - 5" numbers of contrasting color posted near main entrance of building and visble from street per City Ordinance Final- Building • Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 1 of 2 Permit MBtD01-131 1. Contractors working on this project.are required to Gave a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof otthis documentation prior to work may result in job shut down while this is accomplished. 2. If temporary erosion and sediment control (TESC) measures are required, they shag be installed on-site and inspected prior to beginning construction; ca11.385-2294: Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering ingluding nailing, 6oldowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owaer's agent shall review and oversee cornction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A 7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for anon- ~~ residential project. 8. All building permits ezpirc it no progress bas been made within siz months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes is the field. Contact the Building Department ~ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT OIYSITE WITH THE APPROVED PLANS. Ca1148 6oura before you dig for utility line locates 1-800-424-5555 Page 2 of 2