HomeMy WebLinkAboutBLD02-130Watenaso & Ralz Banding
181 Qafney Street, Suih 301
Port Townsend, WA 90368
Phone: 360-379-3208 Fss 360-379-6921
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD02-130R-1 Issued: 08/14/02 Parcel Number: 989 703 601
Job Address: 1300 Water Street Suite #103 Zoning: C-HI Construction Type: VV=N
Occupancy: B -restaurant < 50 people Total Occupant Load: 43
Nature of Work: Revision #1: Install Restaurant Ventilation Use of Building: Dinine
Tenant: "Fresh Press" -Albert Mendez Contractor: Northern Heating & Sheetmetal
NORTHHM006DG
GENERAL CONDITIONS APPLY -SEE LAST PAGE
NOTE: Unit shall be under the parapet and not visible from Water Street, or HPC review is
required prior to installation.
RE UIRED INSPECTIONS
APPROVED/DATE
FRAMING/MECHANICAL
Manufacturer's Installation Manual shall be on-site at
time of inspection
Ventilation -minimum 932 CFMrequired
Positive Connections
FINAL -see also original permit BLD02-130
Fresh Air Certification required from installer
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit #BI,D02-130
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this docnmentatlon
prior to work may result in job shut down while this is accomplished
2. Temporary erosion and sediment control (TFSC) measures shall be installed on-site and
inspected prior to beginning rnnstruction; call 385-2294, press 3. Measures shall include
installation of silt fencing and graveled construction entrance (see attached detat7s). Adjace~
rights-of-way shall be kept free of dirt debris. Soils eaposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction incomplete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed
6. The Building Department is enable to pass Snal inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294,
press 3. A minimum of twenty-four hours notice is required. Public Works aonroval must be
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residentlal project.
8. Ail building permits expire if no progress has been made within sin months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
9. POST THIS PERMIT ON-STTE WITH THE APPROVED PLANS.
Call 48 hours before you dig for atility line locates
i-800-424-5555
Page 2 of 2
wowmengx,~a~a~
tst QwneS so<ee, suite 301
Foot 7ownaead, wava36e
Phone: (360) 37A3Z06 Fex: (360) 3657673
C~
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION STTE
Ca11385-2294 for Inspection
Permit Number: BLDO2-130 Issued: 07/17/02 Parcel Number: 989703601
Job Address: 1300 Water Street Suite 301 Zoning: C=III Type: V_N Occupancy: B
Nature of Work: Tenant Improvement. Retail to Restaurant/JuiceBav: See Attached Scone of Work
Owner: Albert Mendez "Fresh Press" Contractor: Same as -Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
Building - Type I Hood Fire Suppression System
RE UIRED INSPECTIONS
APPROVED/DATE
DEMOLITION
Materials from demolition shall be deposited in approved
areas off-site that meet all applicable codes and
ordinances
PLUMBING -Barrier Free Design Required
Drain Waste & Vent
~'~'7 ~~j~ 7-~ ~/~~~,~
Water Supply
Gas SuPP1Y
Air Gaps @ food prep sinks and condensate drains
Trap Seal Protection required for Floor Drains
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Grease Trap
• Call 48 boors before you dig for utility line locates
I-800-424-5555
Page 1 of 3
~~~
REniliRF,n 1NSPF,f'Tf(1NC APPRnVFnmATR
MECHAI~IICAL
Type IHood -manufacturer's installation instructions
on- site at time of inspection
Appliance/Exhaust Interlock ~ v ~ v v
Exhaust Outlet Clearance - 2' above roof; S other
Type I Duct Gage
Duct Joints/Seams -continuous liquid-tight weld
Grease Duct Supports - no penetration of duct walls
Duct Slope'/+:12
Duct/Enclosure Separation - 3" min; 12" max.
Duct/Enclosure Shaft -one-hour construction
Cleanouts
Air Velocity -1500 - 2500 fpm
Duct/Combustible Clearance -18"; 3" from
non-combustibles
Hood Flashing -less than 12" from ceiling or walls
requires flashing with 22 gage steel
Duct Insulation -make up air: R 3.3
Grease Filters -see UMC 508.5 & notes on plans
Canopy Hood -installed per manufacturer's installation
Instnictions
LPG Kitchen Stove .
Environmental Air Exhaust Ducting (with backdraft
dampers), insulation (R-4) and termination (3 feet from
openings into building)
FRAMING- Ventilation System Specs to 6e
Submitted, Reviewed & Approved prior to framing
inspection
Barrier Free Design Required
Walls
Landings
Thresholds
Fire Blocking
DRYWALL NAILING
Walls ~
~~~
~
Ceilings 7
~
One-Hour Shaft
Cati 48 hours before you dig for utility tine locates
I-800-424-5555
Page 2 of 3
•
~-
Plumbing -barrier free
Mechanical
Exit Signage & Illumination
Fire Department Approval
Health Department Approval
Electrical (L & n
Property address posted -man. 5"numbers
Final -Building
9/~~la
GENERAL CONDITIONS
~~,~
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construMion shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspeMion report corrections are completed.
6, The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works anoroval must be received prior to
scheduling the Building DeoartmenYs final inspeMion.
7, Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspeMion per year to keep your
.building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department Q 379-3208 prior to making changes to the approved plans,
• 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-4245555
Page 3 of 3
z--~