CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Can 385-2294 for Inspection
Permit Number:BLD02-122R-l
Issued: 10/07/02
Parcel Number: 993 800 025
Job Address: 2599 Seaview Drive
Zoning:.M Type: V-N Total Occupant Load: No chan!!e
Occupancy: R-3 Nature of Work: Revision #1: make downstairs bedroom a den bv deletin!! the closet.
and add a closet to the den to make a bedroom: add dry bar in livinl!' room: omit post and beam in I!'ara!!e
and substitute 20" series 600 BCl's (iU 16" o.c.: increase deck from 8 to 10 feet on one side: add tub to
powder room: omit hall closet and replace with half wall: cantilever entry and add two steDs inside: add
Jandin!! and stairs to rear entry.
Owner: Dobson Construction Inc.
Contractor: Same as Owner - DBOSOCI012K7
GENERAL CONDmONS APPLY - SEE LAST PAGE
-r 0~O. (<;${}e:lJ
Sez f(L.-{J:.
SEPARATE PERMITS REOUIRED:
Electrical- Contact Labor & Industries@360-417-2702
-For other inspections. see ori2inaI permitBLD02-122.
REOUffiED INSPECTIONS APPROVEDIDATE
PLUMBING: See also original permit for inspection
requirements ,
Rough-In (D-V-T & Clean outs)
Water Supply
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
FRAMING: See also original permitfor inspection
requirements
DecklLanding
Walls
Headers & Beams
Treated Wood to Concrete
Windows - escape
Windows U-factor - .75 or better
NFRC window sticker must be on windows, skylights
and doors at inspection time
.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 012
- - --
REOUIRED INSPECTIONS
I ~~BUi1ding
Perm8" BLD02-122R-1
APPROVEDIDATE
I.
~AJ, C.ONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's rel!'istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to be&inning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. AU elements of engineering including nailing, holdowns, sheathing, and alternate braced wall p8nels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass (mal inspection on your project until Public Works.
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is reauired. Public Works anDroval must be received Drior to
schedulin!! the Buildin!! Denartment's final insnection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for atIeast one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval Drior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
.
Can 48 houn before you dig for utility line locates
1-800-424-5555
Page 2 of2
--
-.
-
Waterman & KatzBuilding
181 Quincy Street,. Suite 301
Port Townsend. WA 98368
Phone: (360) 379.3208 Fax: (360) 385_7675
.
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-122 Issued: 07/05/02 Parcel Number: 993800025
Job Address: 2599 Seaview Drive Zoning: R-I Type: V-N Total Occupant Load: ~
Occupancy: R-3
Nature of Work: Construct Sinl!'le familv residence with I!8ral!e
Owner: Dobson Construction Inc.
Contractor: Same as Owner - DBOSOCI012K7
GENERAL CONDITIONS APPLY - SEE LAST PAGE
SEPARATE PERMITS REOUIRED:
Electrical- Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
TEMP EROSION & SDM'T CONTROL
See General Condition No. 2
Silt Fence as needed
Drive OfT Mat to restrict sediment from leaving
the site
APPROVED/DATE
GROUNDWORK PLUMBING
Pressure Test
Pipe Joints Exposed
Pipe Bedding
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Interior Footings
Porch Piers
Dec Piers
7//2/<71-- f!
{f!
.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
,
Permit # BLD02-122
>
RE UlRED INSPECTIONS
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts & Washers
Waterproofing
APPROVEDIDATE
7/f-t/~ rp
SLAB
R-IO under
Hydronic Tubing
7/3Dto
FLOOR FRAMING
Hydronic Heat Tubing
Joists - BCI plan to be on-site at time of inspection
Treated Wood to Concrete
Positive Connections
HY4~O IO!U!O 7.. ~
PLUMBING:
Rough-In (D-V-T & Clean outs)
Gas Supply
Water Supply
Water Hammer Arrestor @ clothes and dishwasher
Hose Bibs (backflow protection required)
Pi . -3)
Pressure Reduction
Water HeaterlBoiler
Seismic Restraint - 2 places
Pressure relief valve drain to ext .or, terminate
6" - 24" above ground
18" AF.F.
[){))ufW~ Coj)fOtO!
tructions shall be on-site at
loft!j6 7/ CJ
Call 48 hours before you dig for utility line locates
1-800.424-5555
Page 2 of 4
Pcnnit#BLD02.122
.
RE UlRED INSPECTIONS
MING: Street & Utility Development Permit on-
site at time offraming inspection
Walls
Headers & Beams
Treated Wood to Concrete
Ceiling/Roof
Truss Positive Connection - engineered truss plan on-
site @ time of inspection
Roof Venting - @ ridge & eave
Windows - escape
Windows U-factor - .75 or better
NFRC window sticker must be on windows, skylights
and doors at inspection time
Skylights U-factor - .68 or better
Air Seal
Fresh Air Intake (Window Ports)
Doors U-factor - .40 or better
Fire Blocking
Weather Resistive Barrier
Ct(z 9(02-"
- SULATION
'lab wi thermal break (R-IO)
Floor (R- 19)
Walls - (R-19)
Ceiling - (R-30 )
Barnes
Vapor Barrier: paint
cJ~ ~ -/fA I c(?;{}p2-/!f
(!~ / r1jo~ ()/
DRY WALL NAILING
Walls
Ceiling
Interior Braced Wall Panels
GarageIHouse Separation
If1(Ob r!f
.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
.
RE UIRED INSPECTIONS
Permit"BLD02-122
APPROVED/DATE
LPG 1;(2 7jDl.--
i
.
FINAL
Public Works Sign-Off
LPG
House Numbers - 5"minimum
Plumbing
Mechanical/Heating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final- Building
/, Z-f/tJ3
GENERAl, C.ONDITIONS
1. Contractors workinl: on this project are required to have a Labor & Industries contractor's re!!istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panelS.
(ABWP) require-inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum oftwentv-four hours notice is reauired. Public Works aooroval must be received orior to
schedulin!!' the Build;n!!' Deoartment's final insoection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval orior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4of4
.