HomeMy WebLinkAboutBLD02-119
.
.
.
w....... '" Klitz. BuUdInc
J.J__........l
PM T......... WA 98368
-'360-379-3208 _361-'85-'67.
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Can 385-2294 for Inspection
Permit Number: BLD02-119
Parcel Number: 999 100 160
Issued: 07/02/02
Job Address: 2073 Elizabeth Place
Zoning: R-II
Type: V-N Occupancy: R-3
Total Occupant Load:~
Nature of Work: Set new manufactured home: add deck.
Owners: Edward and Laurel Abel Contractor: Kozeliskv's Home Service W AINS#062
"'*"'*InstaJler: See Attached InstaJler Tal!"'***
GENERAL CONDITIONS APPLY - SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical- Contact Labor & Industries @ 360-417-2702
NOTE: Set-up manual shall be on-site at time of inspection.
REOUIRED INSPECTIONS APPROVEDIDATE
TEMP EROSION & SEDIMENT CONTROL
See general condition #2
Silt Fence as needed
Drive Off Mat to prevent sediment from leaving the site
FOOTINGS/SLAB '7jtI/O~ f(
Setbacks
Forms
Reinforcement
Footings - minimum 4" per installation manual.
FLOOR FRAMING (prior to skirting) 7jl/o/ OJ- Lit!
Anchors
Steel Support Piers - Load-stamped and installed per
manufacturer's installation manual; clearance of 18" min. I
from lowest point of 1-beam and the ground or footing for
min. of 75% of area under home will" min. elsewhere
unless installation manual specifies; otherwise area
around home graded to provide runoff away from home.
Can 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of3
RE RED INSPECfIONS
PLUMBING:
Water Supply - Main shut-oflvalve (port or ball valve)
installed in water supply piping prior to COIJIttIdion to
. home, min. %" diameter, same as supply pipe
Pressure Reduction Valve if> 80 psi
Hose Bibs (backflow protection required)
Pipe Insulation - Outside & in crawl space
Pressure Test -100 p.s.i.jor 15 minutes
Pressure relief valve drain - to exterior of skirting,
exhaust downward between 6" and 24" above ground
~~~p~-~~dmm~'~rfoot
P_IIIILD02-I1'
APPROVEDIDATE
.
12JQ{Ol-Gp
MECHANICAL (!fJ
Ducts & Duct Insulation
Dryer Exhaust - vented to outside. &tension into crawl 1/ V tt{ OU ,
.space requires venting through skirting with no dips;
follow dryer manufacturer's instructions; total combined
length of dueling not to exceed 14' wI1-9r1 elbows .
FRAMING:
Deck - Pressure-treated or of natural resistance to decay.
VAPOR BARRIER
6 mil black poly ground cover (not required where area
under home is concrete slab floor with a minimum
thickness of 3-* inches)
FINAL
Public Works Sign-Off
Electrical (L & I) Sign-Off
House Number - minimum 5" numbers
Plumbing
Mechanical
Fina1- Building
No holes or gaps greater than ~" allowed in skirting.
Crawl space ventilation per installation manual @ 1/150
(14 required), located clase to corners, on at least two
opposing sides for cross ventilation.
Crawl space access must provide access to all areas
under home, minimum 18" x 24", covered with vinyl,
pressure treated wood or metal.
II
I Oft (07/ Cf
.
Call 48 bopn before )'ou dig for utility line locates
1-800-424-5555
Page20f3
-
.
.
.
PennIt#BLDOZ-119
GENERAL CONDmONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
rel!istration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdoWDs, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Can 48 hours before you dig for ntility line locates
1-800-424-5555
Page 3 ofl
..
.
.